Hasanain Kahtan Abdulkhalik Alalwan

Dr. Hasanain Kahtan Abdulkhalik Alalwan


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2017 in Frontiers in Microbiology
Verified
Journal Article
Open access
HAHasanain Kahtan Abdulkhalik Alalwan
Hasanain Kahtan Abdulkhalik Alalwan
RRRanjith Rajendran
Ranjith Rajendran
DLDavid F. Lappin
David F. Lappin
Emilie CombetEmilie Combet
Emilie Combet
MSMuhammad Shahzad
Muhammad Shahzad
GRGordon Ramage
Gordon Ramage
The use of natural compounds as an alternative source of antimicrobials has become a necessity given the growing concern over global antimicrobial resistance. Polyphenols, found in various edible plants, offers one potential solution to this. We aimed to investigate the possibility of using curcumin within the context of oral health as a way of inhibiting and preventing the harmful development of Candida albicans biofilms. We undertook a series of adsorption experiments with varying concentrations of curcumin, showing that 50 ug/ml could prevent adhesion. This effect could be further synergised by the curcumin pretreatment of yeast cells to obtain significantly greater inhibition (>90%, p<0.001). Investigation of the biological impact of curcumin showed that it preferentially affected immature morphological forms (yeast and germlings), and actively promoted aggregation of the cells. Transcriptional analyses showed that key adhesins were down-regulated (ALS1 and ALS3), whereas aggregation related genes (ALS5 and AAF1) were up-regulated. Collectively, these data demonstrated that curcumin elicits anti-adhesive effects and that induces transcription of genes integrally involved in the processes related to biofilm formation. Curcumin and associated polyphenols therefore have the capacity to be developed for use in oral healthcare to augment existing preventative strategies for candidal biofilms on the denture surface.

1 January 2017 in Journal of Medical Microbiology
Verified
Journal Article
Closed access
LOLindsay E. O’dOnnell
Lindsay E. O’dOnnell
HAHasanain Kahtan Abdulkhalik Alalwan
Hasanain Kahtan Abdulkhalik Alalwan
RKRyan Kean
Ryan Kean
GCGareth Calvert
Gareth Calvert
CNChristopher John Nile
Christopher John Nile
LSLeighann Sherry
Leighann Sherry
Approximately 20 % of the UK population wear some form of denture prosthesis, resulting in denture stomatitis in half of these individuals. Candida albicans is primarily attributed as the causative agent, due to its biofilm -forming ability. Recently, there has been increasing evidence of C. albicans biofilm heterogeneity and the negative impact it can have clinically; however, this phenomenon has yet to be studied in relation to denture isolates. The aims of this study were to evaluate C. albicans biofilm formation of clinical denture isolates in a denture environment and to assess antimicrobial activity of common denture cleansers against these tenacious communities. C. albicans isolated from dentures of healthy and diseased individuals was quantified using real-time PCR and biofilm biomass assessed using crystal violet. Biofilm development on the denture substratum poly(methyl methacrylate), Molloplast B and Ufi-gel was determined. Biofilm formation was assessed using metabolic and biomass stains, following treatment with denture hygiene products. Although C. albicans was detected in greater quantities in diseased individuals, it was not associated with increased biofilm biomass. Denture substrata were shown to influence biofilm biomass, with poly(methyl methacrylate) providing the most suitable environment for C. albicans to reside. Of all denture hygiene products tested, Milton had the most effective antimicrobial activity, reducing biofilm biomass and viability the greatest. Overall, our results highlight the complex nature of denture- related disease, and disease development cannot always be attributed to a sole cause. It is the distinct combination of various factors that ultimately determines the pathogenic outcome.

1 February 2018 in Nanomedicine: Nanotechnology, Biology and Medicine
Verified
Journal Article
Closed access
PDF file
HAHasanain Kahtan Abdulkhalik Alalwan
Hasanain Kahtan Abdulkhalik Alalwan
CNChristopher John Nile
Christopher John Nile
RRRanjith Rajendran
Ranjith Rajendran
RMRobert McKerlie
Robert McKerlie
PRPaul Reynolds
Paul Reynolds
GRGordon Ramage
Gordon Ramage

19 January 2026 in Prosthesis
Verified
Journal Article
Open access
PDF file
Ihab Nabeel SafiIhab Nabeel Safi
Ihab Nabeel Safi
HAHasanain Kahtan Abdulkhalik Alalwan
Hasanain Kahtan Abdulkhalik Alalwan
Mustafa S. TukmachiMustafa S. Tukmachi
Mustafa S. Tukmachi
DMDhuha Hussein Mohammed
Dhuha Hussein Mohammed
MAMaryam Sinan Al-yasari
Maryam Sinan Al-yasari
Background/Objectives: The use of zirconia implants is gaining traction as a potential alternative to titanium. Although having excellent properties, the zirconia surface has limited osteogenic potential. The purpose of this study was to produce, for the first time, mechanically stable, thick micron-scale hydroxyapatite coatings on zirconia implant material using radiofrequency (RF) magnetron sputtering. Methods: Zirconia samples were coated with HA using an RF magnetron sputtering device at a temperature of 125 °C for 20 h with 155 W of power. The procedure included rotating the substrate at a speed of 10 rpm while an argon gas flow was maintained continuously. Field emission scanning electron microscopy (FESEM), energy-dispersive X-ray (EDX) analysis, atomic force microscopy, and Vickers hardness measurements were used to evaluate the coat’s characteristics. Results: A smooth hydroxyapatite coating layer that was consistent and free of cracks was observed in all FESEM pictures. The EDX study revealed that the substrate surface contains HA particles, and the ratio of calcium (Ca) to phosphorus (P) was 16.58 to 11.31, which is very close to the ratio in original HA. FESEM cross-section pictures showed good adhesion between the coating and substrate without any gaps, and the coating thickness was 5 µm on average. A statistically significant difference was found in the roughness analysis between the samples of uncoated Zr and HA-coated Zr (p-value < 0.05). Conclusions: Zirconia implant material can be coated with a uniform layer of HA, displaying good adhesion and a thickness of a few micrometers when using magnetron sputtering for an extended period of time.