31 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HPHwaPyeong Park
HwaPyeong Park
Seung Jin ChangSeung Jin Chang
Seung Jin Chang
Jae-Young ParkJae-Young Park
Jae-Young Park
MKMina Kim
Mina Kim
Wan KimWan Kim
Wan Kim
SCSuyong Chae
Suyong Chae
Photovoltaic (PV) power generation has become widespread owing to the global need to achieve carbon neutrality. With the increase in the number of PV systems, a broken connector in the PV panel induces a dc series arc fault condition. Therefore, arc fault detection technology becomes significant to guarantee the safety and reliability of PV systems. However, the series arc fault condition is similar to that of the normal operation with a small current variation, which makes it difficult to classify the normal and arc fault conditions. In this article, the resonant filter is proposed to improve the dc series arc fault detection capability. The characteristics of arc fault current are analyzed with the considerations of PV and converter impedance. The operational principle and design methodology of the proposed resonant filter are analyzed to clarify the arc fault signal through decoupling with the converter impedance. In addition, the algorithm for arc fault detection is designed with the proposed resonant filter. The experiment setups are designed with a dc optimizer and two commercial inverters, which can verify the arc fault detection performance with the proposed resonant filter.

5 February 2025 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
BKByungki Kim
Byungki Kim
MKMina Kim
Mina Kim
Wan KimWan Kim
Wan Kim
HPHwaPyeong Park
HwaPyeong Park
Module level power electronics can achieve the maximum power generation for each photovoltaic (PV) panel. However, it increases the possibility of an arc fault between the PV panel and the DC/DC converter. The damaged and loose connector can induce the DC series arc fault condition. Previously, the frequency-domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for series arc fault detection. However, the arc fault detection performance is not consistent according to the system configuration. This paper investigates the DC series arc fault capability using the frequency spectrum analysis based on the impedance of the power converter. From the characteristics of the arc fault condition, the boost converter comprising the LCL-type filter can clarify the arc fault condition in the frequency-domain analysis. The operational principle and design methods are analyzed while considering series arc fault detection and power conversion. The experimental results using an 800-W prototype converter can verify the arc fault detection using the frequency spectrum analysis.

14 April 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
BKByungki Kim
Byungki Kim
Wan KimWan Kim
Wan Kim
MJMinseo Jeon
Minseo Jeon
SSSung-Geun Song
Sung-Geun Song
HPHwaPyeong Park
HwaPyeong Park
Module-level power electronics can achieve the maximum power generation for each photovoltaic (PV) panel with overcoming the partial shading. However, it increases the possibility of dc series arc fault condition between the PV panel and converter. The current modulation can detect and extinguish the dc series arc fault condition using the characteristics of arc resistance. However, this method degrades the power generation according to inaccurate fault detection. This article proposes the dc series arc fault detection and extinguishing with coordination of current modulation and machine learning method, which can improve the accuracy of fault detection through double screening. The proper machine learning algorithm can minimize the undesired trigger of current modulation, which improves the PV power generation at normal condition. The proposed method is possible to distinguish between arc fault and normal conditions regardless of impedance and external changes. The operational principle is analyzed to coordinate the current modulation and machine learning. The experimental results using 800-W prototype dc–dc converter can verify the arc fault detection and extinguishing.

17 March 2025 in IEEE Access
Verified
Journal Article
Open access
BKByungki Kim
Byungki Kim
Taesic KimTaesic Kim
Taesic Kim
Wan KimWan Kim
Wan Kim
HPHwaPyeong Park
HwaPyeong Park
Power generation using a photovoltaic (PV) system is increasing to achieve the carbon neutrality. Module-level power electronics (MLPEs) can optimize power generation for each PV panel. However, it increases the possibility of DC series arc fault condition between the PV panel and MLPEs. The broken and loose connector and damaged cable can induce a DC series arc fault condition. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for DC series arc fault detection. It requires the auxiliary device to detect the arc failure, which degrades the cost-effectiveness of PV systems. In addition, they cannot achieve the fault detection and extinguishing in the same time. This paper proposes a modulation algorithm of non-inverting buck-boost converter (NIBBC) to achieve the DC series arc fault detection and extinguishing. The proposed method uses the characteristics of PV, NIBBC, and arc fault to classify the normal and arc fault conditions. The operational principle is analyzed to design the modulation method according to operating modes. The 800-W prototype NIBBC is used to verify the performance of series arc fault detection and extinguishing.

25 February 2025 in IEEE Access
Verified
Journal Article
Open access
CKChun-Sung Kim
Chun-Sung Kim
Wan KimWan Kim
Wan Kim
HPHwaPyeong Park
HwaPyeong Park
A module-level power electronics for photovoltaic (PV) systems can achieve the maximum power generation for each PV panel, which can overcome the partial shading of PV systems. However, it increases the possibility of series arc fault condition between the PV panel and module-level power electronics. The damaged and loose connector can induce the DC series arc fault condition. This paper investigates DC series arc fault detection capability based on the non-inverting buck-boost converter using the resonant filter for the PV applications. From the arc fault characteristics, the designed impedance model can clarify the DC series arc fault condition. The operational principle and design methodology of proposed buck-boost converter are analyzed with considerations of power conversion and series arc fault detection capability. The experimental results using the 800-W prototype converter can verify the series arc fault detection capability with proposed topology using the resonant filter.

20 June 2025 in IEEE Access
Verified
Journal Article
Open access
Wan KimWan Kim
Wan Kim
HPHwaPyeong Park
HwaPyeong Park
With the recent surge in the use of photovoltaic (PV) power systems, the incidence of DC series arc faults has significantly increased, which cause voltage drops within these systems. Previous studies have proposed arc fault detection algorithms based on these input voltage drops. However, voltage drops can also occur under normal conditions, such as irradiance variations. Operating the conventional arc fault detection algorithm under normal conditions, such as irradiance variations, results in a reduction in PV power generation. To overcome these limitations, this paper proposes a new algorithm that not only detects and extinguishes DC series arc faults but also minimizes the reduction in PV power generation under normal conditions, such as irradiance variations. The proposed method uses Q1 and Q2 of a non-inverting buck-boost converter to separate the detection and extinguishing processes of arc faults and detects arc faults through sinusoidal current control. The algorithm was validated through simulation models and experiments, and it achieved a power generation efficiency of 75.84% under irradiance variation, demonstrating effective operation without unnecessary energy loss and confirming its ability to enhance the stability and reliability of PV systems. Furthermore, it holds promise for application in more complex power systems in the future and is expected to contribute to a wide range of power system applications.