Jae-Young Park

Prof. Jae-Young Park

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2022 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
GLGiho Lee
Giho Lee
Jae-Young ParkJae-Young Park
Jae-Young Park
JBJaepil Ban
Jaepil Ban
YKYoungjin Kim
Youngjin Kim
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
Hydrogen energy storage (HES) has attracted renewed interest as a means to enhance the flexibility of power balancing to achieve the goal of a low-carbon grid. This paper presents an innovative data-driven HES model that reflects the interactive operations of an electrolyzer, a fuel cell, and hydrogen tanks. A model predictive control strategy is then developed, in which HES units support the frequency regulation (FR) of a microgrid (MG). In the proposed strategy, an MG-level controller is designed to optimize power sharing, to allow the HES units to respond quickly to power supply-and-demand imbalances, while distributed generators compensate for any remaining imbalance. The MG-level controller cooperates with the HES-level controllers, which change the operating modes and override the FR supports based on the hydrogen levels. Small-signal analysis is conducted to evaluate the contribution and sensitivity of the FR supports. Comparative case studies are also carried out, wherein HES model accuracy is verified and a hardware-in-the-loop simulation is implemented. The results of the small-signal analysis and case studies confirm that the proposed strategy is effective for reducing frequency deviations under various MG conditions, characterized by the net load demand, line congestion, plug-and-play, model parameters, and communication time delays.

6 October 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Jae-Young ParkJae-Young Park
Jae-Young Park
JCJae-won Chang
Jae-won Chang
The grid-forming distributed generators (GFM-DGs) have attracted much attention as a key technology for realizing 100% renewable energy grids. This paper presents a novel control strategy to ensure the reliable operation of a renewable energy source (RES)-based GFM-DG even during weather variations. The GFM-DG connects a RES to the grid via source- and grid-side converters, with the converters’ common DC-link voltage $V_{DC}$ indicating the power balance between the RES and the grid. We begin by identifying the limitation of conventional strategies in maintaining $V_{DC}$ against severe weather. To address the limitation, we propose a coordinated strategy for both source- and grid-side converters to regulate $V_{DC}$ cooperatively, ensuring GFM-DG stability even in adverse weather conditions while also achieving decentralized power sharing and contributions to frequency inertia and damping. The proposed strategy is applicable to photovoltaic- and wind turbine-based generators, as well as energy storage systems. A guideline for control parameter design and stability margin analysis for weather conditions are also provided. The effectiveness of the proposed strategy is validated via small-signal analysis and simulation case studies under various conditions of 100% renewable energy grids, characterized by severe weather, load demand changes, actual line impedances, and a grid fault.

22 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
BJByeong-Cheol Jeong
Byeong-Cheol Jeong
DSDong-Hwan Shin
Dong-Hwan Shin
IJIm Jaebeom
Im Jaebeom
Jae-Young ParkJae-Young Park
Jae-Young Park
YKYoungjin Kim
Youngjin Kim
Optimal operation scheduling of energy storage systems (ESSs) has been considered as an effective way to cope with uncertainties arising in modern grid operation such as the inherent intermittency of the renewable energy sources (RESs) and load variations. This paper proposes a scheduling algorithm where ESS power inputs are optimally determined to minimize the microgrid (MG) operation cost. The proposed algorithm consists of two stages. In the first stage, hourly schedules during a day are optimized one day in advance with the objective of minimizing the operating cost. In the second stage, the optimal schedule obtained from the first stage is repeatedly updated every 5 min during the day of operation to compensate for the uncertainties in load demand and RES output power. The ESS model is developed considering operating efficiencies and then incorporated in mixed integer linear programming (MILP). Penalty functions are also considered to acquire feasible optimal solutions even under large forecasting errors in RES generation and load variation. The proposed algorithm is verified in a campus MG, implemented using ESSs and photovoltaic (PV) arrays. The field test results are obtained using open-source software and then compared with those acquired using commercial software.

31 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HPHwaPyeong Park
HwaPyeong Park
Seung Jin ChangSeung Jin Chang
Seung Jin Chang
Jae-Young ParkJae-Young Park
Jae-Young Park
MKMina Kim
Mina Kim
Wan KimWan Kim
Wan Kim
SCSuyong Chae
Suyong Chae
Photovoltaic (PV) power generation has become widespread owing to the global need to achieve carbon neutrality. With the increase in the number of PV systems, a broken connector in the PV panel induces a dc series arc fault condition. Therefore, arc fault detection technology becomes significant to guarantee the safety and reliability of PV systems. However, the series arc fault condition is similar to that of the normal operation with a small current variation, which makes it difficult to classify the normal and arc fault conditions. In this article, the resonant filter is proposed to improve the dc series arc fault detection capability. The characteristics of arc fault current are analyzed with the considerations of PV and converter impedance. The operational principle and design methodology of the proposed resonant filter are analyzed to clarify the arc fault signal through decoupling with the converter impedance. In addition, the algorithm for arc fault detection is designed with the proposed resonant filter. The experiment setups are designed with a dc optimizer and two commercial inverters, which can verify the arc fault detection performance with the proposed resonant filter.

29 October 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
BJByeong-Cheol Jeong
Byeong-Cheol Jeong
DKDohoon Kwon
Dohoon Kwon
Jae-Young ParkJae-Young Park
Jae-Young Park
YKYoungjin Kim
Youngjin Kim
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
High-voltage direct-current (HVDC) systems using voltage source converters (VSCs) have been developed to suppress voltage fluctuations in offshore grids due to the intermittent power generation of offshore wind farms (OWFs). This paper proposes a new strategy for the optimal secondary voltage control of HVDC-linked OWFs. In the proposed strategy, optimal coordinated control of an HVDC system and OWFs is achieved to minimize real-time voltage fluctuations throughout an offshore grid. A full-order dynamic model of HVDC-linked OWFs is implemented, and its unobservable and uncontrollable state variables are then eliminated using a model reduction algorithm. Given the dynamic model, a linear quadratic Gaussian regulator is designed for optimal coordinated control, and an eigenvalue analysis is conducted focusing on the effects of communication time delays on the stability of the proposed strategy. Simulation case studies are also carried out to verify that the proposed strategy more effectively improves real-time regulation of offshore grid voltages, compared to conventional strategies, while ensuring voltage stability even for relatively large delays in communications systems.

20 July 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Jae-Young ParkJae-Young Park
Jae-Young Park
JBJaepil Ban
Jaepil Ban
YKYoungjin Kim
Youngjin Kim
XLXiaonan Lu
Xiaonan Lu
Network reconfiguration (NR) has received attention due to its potential to improve grid resilience by realizing self-healing microgrids (MGs). This paper proposes a new strategy for the real-time frequency regulation of a reconfigurable MG, wherein the feedforward control of synchronous and inverter-interfaced distributed generators (DGs) is achieved in coordination with the operations of sectionalizing and tie switches (SWs). This enables DGs to compensate more quickly, and preemptively, for a forthcoming variation in load demand due to NR-aided restoration. An analytical dynamic model of a reconfigurable MG is developed to analyze the MG frequency response to NR and determine the desired dynamics of the feedforward controllers when integrated with feedback loops for inertial response emulation and primary and secondary frequency control. A small-signal analysis is conducted to analyze the contribution of the feedforward control to the MG frequency regulation. Simulation case studies of NR-aided load restoration are also performed. The results of the small-signal analysis and case studies confirm that the proposed strategy is effective for the improvement of the MG frequency regulation under various conditions of load demand, model parameter errors, and communication time delays.