Polykarpos Evripidou

Dr. Polykarpos Evripidou


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Nutrients
Verified
Journal Article
Open access
PDF file
TDTriantafyllos Didangelos
Triantafyllos Didangelos
Eleni KarlaftiEleni Karlafti
Eleni Karlafti
Evangelia KotzakioulafiEvangelia Kotzakioulafi
Evangelia Kotzakioulafi
PGParthena Giannoulaki
Parthena Giannoulaki
ZKZisis Kontoninas
Zisis Kontoninas
Konstantinos KantartzisKonstantinos Kantartzis
Konstantinos Kantartzis
Aim: To investigate the efficacy of Palmitoylethanolamide (PEA, 300 mg), Superoxide Dismutase (SOD, 70 UI), Alpha Lipoic Acid (ALA, 300 mg), vitamins B6 (1.5 mg), B1 (1.1 mg), B12 (2.5 mcg), E (7.5 mg), nicotinamide (9 mg), and minerals (Mg 30 mg, Zn 2.5 mg) in one tablet in people with Diabetic Neuropathy (DN). Patients–methods: In the present pilot study, 73 people (age 63.0 ± 9.9 years, 37 women) with type 2 Diabetes Mellitus (DMT2) (duration 17.5 ± 7.3 years) and DN were randomly assigned to receive either the combination of ten elements (2 tablets/24 h) in the active group (n = 36) or the placebo (n = 37) for 6 months. We used the Michigan Neuropathy Screening Instrument Questionnaire and Examination (MNSIQ and MNSIE), measured vibration perception threshold (VPT) with biothesiometer, and Cardiovascular Autonomic Reflex Tests (CARTs). Nerve function was assessed by DPN Check [sural nerve conduction velocity (SNCV) and amplitude (SNAP)]. Sudomotor function was assessed with SUDOSCAN, which measures electrochemical skin conductance in hands and feet (ESCH and ESCF). Pain score (PS) was assessed with Pain DETECT questionnaire. Quality of life was assessed by questionnaire. Results: In the active group, there was a large improvement of pain (PS from 20.9 to 13.9, p < 0.001). There was also a significant improvement of vitamin B12 (B12) levels, MNSIQ, SNCV, VPT, and ESCF (222.1 vs. 576.3 pg/ mL, p < 0.001; 6.1 vs. 5.9, p = 0.017; 28.8 vs. 30.4, p = 0.001; 32.1 vs. 26.7, p = 0.001; and 72.2 vs. 74.8, p < 0.001 respectively). In the placebo group, neither pain (21.6 vs. 21.7, p = 0.870) or any other aforementioned parameters changed significantly, and MNSIE worsened (2.9 vs. 3.4, p < 0.001). As a result, changes from baseline to follow-up in pain, B12 levels, VPT, and MNSIQ differed significantly between the two groups (p < 0.001, 0.025, 0.009, and <0.001, respectively). CARTs, SNAP, ESCH did not significantly change in either of the two groups. Conclusions: The combination of the ten elements in one tablet for 6 months at a daily dose of two tablets in people with DN significantly improves pain, vibration perception threshold, and B12 levels.

Verified
Journal Article
Open access
PDF file
PGParthena Giannoulaki
Parthena Giannoulaki
Evangelia KotzakioulafiEvangelia Kotzakioulafi
Evangelia Kotzakioulafi
ANAlexandros Nakas
Alexandros Nakas
ZKZisis Kontoninas
Zisis Kontoninas
PEPolykarpos Evripidou
Polykarpos Evripidou
TDTriantafyllos Didangelos
Triantafyllos Didangelos
Background: Pregnant women with type 1 diabetes mellitus (T1DM) face an elevated risk of complications for both themselves and their newborns. Experts recommend strict glycemic control. The advanced hybrid closed-loop (AHCL) system, though not officially approved for pregnant T1DM patients, is promising for optimal glycemic control. Methods: We collected CGM metrics, HbA1c levels, insulin pump settings, and doses from a 33-year-old pregnant woman with 23-year history of T1DM from the 6th week of gestation to birth. She was initially on continuous insulin pump therapy with CGM and switched to the AHCL system (MiniMedTM 780G, Medtronic, Northridge, CA, USA) between weeks 13 and 14. Results: The AHCL system improved glycemic control from weeks 14 to 26, achieving international guidelines with TIR = 72%, TAR = 24%, TBR = 4%. At week 30, TIR was 66%, TAR 31%. By altering diet and adding ‘fake carbohydrates’, she maintained TIR ≥ 70%, TBR ≤ 4%, TAR ≤ 26% from week 34 to birth. A healthy 4 kg, 53 cm baby boy was born at week 38. Conclusions: The use of the AHCL system holds significant promise for improving glycemic control in pregnancy. Optimal glycemic control with MiniMedTM 780G in pregnancy requires accurate carbohydrate counting, specific timing of insulin doses in relation to meal consumption and dietary choices that reduce the glycemic load of meals continue to be crucial factors in achieving optimal glycemic control during pregnancy using the MiniMedTM 780G system. Further research and clinical studies are needed to explore the full potential of these advanced systems in managing T1DM during pregnancy and optimizing maternal and neonatal outcomes.

29 June 2024 in Nutrients
Verified
Journal Article
Open access
PDF file
PGParthena Giannoulaki
Parthena Giannoulaki
Evangelia KotzakioulafiEvangelia Kotzakioulafi
Evangelia Kotzakioulafi
ANAlexandros Nakas
Alexandros Nakas
ZKZisis Kontoninas
Zisis Kontoninas
Eleni KarlaftiEleni Karlafti
Eleni Karlafti
TDTriantafyllos Didangelos
Triantafyllos Didangelos
Introduction–Background: Data from experimental trials show that Crocus sativus L. (saffron) is considered to improve glycemia, lipid profile, and blood pressure and reduce oxidative stress. So far, clinical trials have been conducted in individuals with metabolic syndrome and Diabetes Mellitus type 2 (DMT-2). The purpose of this study is to assess the effectiveness of saffron in individuals with Diabetes Mellitus type 1 (DMT-1). Patients–Methods: 61 individuals with DMT-1, mean age 48 years old (48.3 ± 14.6), 26 females (42.6%) were randomized to receive a new oral supplement in sachets containing probiotics, prebiotics, magnesium, and Crocus sativus L. extract or placebo containing probiotics, prebiotics and magnesium daily for 6 months. Glycemic control was assessed with a continuous glucose monitoring system and laboratory measurement of HbA1c and lipid profile was also examined. Blood pressure at baseline and end of intervention was also measured. Individuals were either on a continuous subcutaneous insulin infusion with an insulin pump or in multiple daily injection regimens. Diabetes distress and satiety were assessed through a questionnaire and body composition was assessed with bioelectrical impedance. Results: At the end of the intervention, the two groups differed significantly only in serum triglycerides (p = 0.049). After 6 months of treatment, a significant reduction in the active group was observed in glycated hemoglobin (p = 0.046) and serum triglycerides (p = 0.021) compared to baseline. The other primary endpoints (glycemic control, lipid profile, blood pressure) did not differ within the groups from baseline to end of intervention, and there was no significant difference between the two groups. Diabetes distress score improved significantly only in the active group (p = 0.044), suggesting an overall improvement in diabetes disease burden in these individuals but that was not significant enough between the two groups. Conclusions: A probiotic supplement with saffron extract improves serum triglycerides in well-controlled people with DMT-1 and may potentially be a valuable adjunct for enhancing glycemic control.

11 June 2025 in Diabetology
Verified
Journal Article
Open access
PDF file
IZIoanna Zografou
Ioanna Zografou
PDPanagiotis Doukelis
Panagiotis Doukelis
TKTheocharis Koufakis
Theocharis Koufakis
Evangelia KotzakioulafiEvangelia Kotzakioulafi
Evangelia Kotzakioulafi
PEPolykarpos Evripidou
Polykarpos Evripidou
Konstantinos KantartzisKonstantinos Kantartzis
Konstantinos Kantartzis
Aim: The aim of this study was to evaluate the specificity, sensitivity and accuracy of the Indicator Plaster Neuropad in detecting established Diabetic Autonomic Neuropathy (DAN). Methods: We studied 180 patients with Diabetes Mellitus (DM, mean age 49.5 ± 16 years, 82 with DM type 1). All patients underwent the following Cardiovascular Reflex Tests (CARTs): R-R variation during deep breathing (Mean Circular Resultant (MCR) and standard deviation (SD)), Valsalva maneuver, R-R variability after a rapid change from lying to standing position and postural hypotension. The presence of DAN was established if ≥2 CARTs were abnormal. According to the result the patients were divided into two groups, one with DAN and one without DAN. Assessment with Neuropad was performed also in all patients. Results: Abnormal perspiration with Neuropad (uncompleted or no change in color) was detected in 94 patients. Established DAN was detected in 85 patients. The sensitivity, specificity and accuracy of Neuropad for the diagnosis of established DAN were 87.1%, 78.9% and 82.8%, respectively and area under the curve was 0.846 and 95% CI (0.787, 0.905). Conclusions: Neuropad has high sensitivity, specificity, and accuracy in detecting established DAN, as defined by ≥2 abnormal CARTs.