Linping Du

Dr. Linping Du


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2025 in Frontiers in Preventive Medicine
Verified
Journal Article
Open access
PDF file
LDLinping Du
Linping Du
ZFZihao Fan
Zihao Fan
GHGang He
Gang He
Early diagnosis of pediatric pneumonia is critical for reducing mortality rates, and automated detection based on chest X-rays is key to improving diagnostic efficiency. While deep learning-based object detection algorithms have shown promise in this task, existing methods often suffer from limited generalization and detection risks due to model complexity or loss of detail during feature extraction and upsampling processes. In this paper, we propose an enhanced YOLOv12n model specifically designed for pediatric pneumonia detection. We introduce the DA2C2f module, which leverages multi-level feature processing and deep convolution operations to improve the model's ability to capture complex features at different levels, effectively enhancing classification performance. Additionally, the DySample module utilizes dynamic upsampling to adaptively adjust the sampling points based on the local content of the input feature map, overcoming the limitations of traditional fixed upsampling methods and reducing image blurring and detail loss. Experimental results demonstrate that the proposed improved model outperforms competing models across key metrics, including recall rate, mean average precision (mAP), and model generalization. Specifically, our model achieves a 1.7% improvement in recall rate (85.4%), a 0.4% improvement in mAP@0.5 (84.4%), and a 0.4% improvement in mAP@0.5-0.95 (52.9%). Notably, in bacterial pneumonia detection, our model exhibits the highest average precision (AP) of 86.8%, a 2.2% improvement over YOLOv12n. Ablation studies further validate the critical role of the DA2C2f and DySample modules in enhancing model performance, particularly in improving recall rate while maintaining high detection accuracy. The improved YOLOv12n model holds significant potential for automated pediatric pneumonia diagnosis and provides valuable insights for future medical image analysis applications.

10 January 2026 in Symmetry
Verified
Journal Article
Open access
PDF file
LDLinping Du
Linping Du
XZXiaoli Zhu
Xiaoli Zhu
ZLZhongbin Luo
Zhongbin Luo
YXYanping Xu
Yanping Xu
Pediatric pneumonia detection faces the challenge of pathological asymmetry, where immature lung tissues present blurred boundaries and lesions exhibit extreme scale variations (e.g., small viral nodules vs. large bacterial consolidations). Conventional detectors often fail to address these imbalances. In this study, we propose YOLO-SMD, a detection framework built upon a symmetrical design philosophy to enforce balanced feature representation. We introduce three architectural innovations: (1) DySample (Content-Aware Upsampling): To address the blurred boundaries of pediatric lesions, this module replaces static interpolation with dynamic point sampling, effectively sharpening edge details that are typically smoothed out by standard upsamplers; (2) SAC2f (Cross-Dimensional Attention): To counteract background interference, this module enforces a symmetrical interaction between spatial and channel dimensions, allowing the model to suppress structural noise (e.g., rib overlaps) in low-contrast X-rays; (3) SDFM (Adaptive Gated Fusion): To resolve the extreme scale disparity, this unit employs a gated mechanism that symmetrically balances deep semantic features (crucial for large bacterial shapes) and shallow textural features (crucial for viral textures). Extensive experiments on a curated subset of 2611 images derived from the Chest X-ray Pneumonia Dataset demonstrate that YOLO-SMD achieves competitive performance with a focus on high sensitivity, attaining a Recall of 86.1% and an mAP@0.5 of 84.3%, thereby outperforming the state-of-the-art YOLOv12n by 2.4% in Recall under identical experimental conditions. The results validate that incorporating symmetry principles into feature modulation significantly enhances detection robustness in primary healthcare settings.