Zeynep Hale Keleş

Dr. Zeynep Hale Keleş

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2020 in Meandros Medical and Dental Journal
Verified
Journal Article
Closed access
ZKZeynep Hale Keleş
Zeynep Hale Keleş
HSHande Şar Sancaklı
Hande Şar Sancaklı

10 April 2026 in Materials
Verified
Journal Article
Open access
PDF file
ZKZeynep Hale Keleş
Zeynep Hale Keleş
VIVasfiye Isik
Vasfiye Isik
Soner SismanogluSoner Sismanoglu
Soner Sismanoglu
This in vitro study evaluated and compared the surface roughness, color stability, and gloss of two single-shade composite resins after simulated toothbrushing, and investigated the correlations among these parameters. Twenty disk-shaped specimens (n = 10 per group) were prepared from two single-shade composite resins (Material A and Group B) and subjected to simulated toothbrushing up to 15,000 cycles. Surface roughness (Ra) was measured at baseline and after 5000, 10,000, and 15,000 cycles. Color parameters (CIE Lab*) and gloss (60°) were measured at baseline and after 15,000 cycles. Color change was calculated using the CIEDE2000 formula (ΔE00). Data were analyzed using two-way mixed ANOVA, t-tests, and Pearson correlation analysis (α = 0.05). Both materials showed progressive increases in surface roughness. Material B exhibited significantly higher Ra values than Material A from 10,000 cycles onward (p < 0.01). After 15,000 cycles, Material B demonstrated significantly greater color change (ΔE00: 2.21 ± 0.18 vs. 1.48 ± 0.13; p < 0.001), exceeding the acceptability threshold (ΔE00 = 1.8), while Material A remained clinically acceptable. Material B also showed greater gloss reduction (60% vs. 35%; p < 0.001). Strong correlations were found between surface roughness and both gloss change (r = −0.919) and color change (r = 0.826). Material A demonstrated greater resistance to surface degradation and better preservation of optical properties compared to Material B. Surface roughness was identified as the common underlying factor driving both color instability and gloss reduction in single-shade composites. Clinical Significance: Not all single-shade composites perform equally under mechanical aging. Clinicians should consider the filler technology and long-term surface stability when selecting single-shade composite resins for clinical use.

2 July 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ZKZeynep Hale Keleş
Zeynep Hale Keleş
Musa Kazım ÜçüncüMusa Kazım Üçüncü
Musa Kazım Üçüncü
This study aimed to evaluate the influence of surface polishing on the reliability of microhardness ratio-based assessment of depth of cure in resin-based composites. A total of 60 composite discs (n = 10 per group) were prepared using six different resin-based composite materials. The tested materials included two conventional sculptable composites (Tetric Prime and Neo Spectra ST HV), one conventional flowable composite (Tetric EvoFlow), one bulk-fill sculptable composite (Tetric PowerFill), and two bulk-fill flowable composites (Tetric PowerFlow and SDR Plus), all prepared according to the respective manufacturers’ instructions. Prior to microhardness measurements, the bottom-to-top surface microhardness ratios were assessed using three distinct approaches: 1)unpolished bottom/unpolished top, 2) unpolished bottom/polished top, 3) polished bottom/polished top. Vickers Microhardness Numbers (VHN) were determined under a load of approximately 50 g applied for 15 s. The threshold value for acceptable depth of cure was set at 80%. Statistical analysis revealed significant differences in the depth of cure measurements of resin-based materials when evaluated using the unpolished bottom/polished top, polished bottom/top, and unpolished bottom/top approaches (p < 0.001). Among these, the lowest degree of conversion was consistently observed in the configuration where the bottom surface remained unpolished while the top surface was polished. Notably, SDR was the only material that surpassed the 80% threshold across all three evaluation methods. The unpolished bottom/polished top configuration resulted in the lowest conversion rates, primarily due to the increase in microhardness values caused by polishing the top surface. Whether or not surface finishing is applied has a substantial impact on the mechanical performance, and should therefore be thoughtfully considered when interpreting the effectiveness of polymerization.

2 April 2024 in Journal of Consumer Health on the Internet
Verified
Journal Article
Closed access
ZKZeynep Hale Keleş
Zeynep Hale Keleş

1 July 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
Musa Kazım ÜçüncüMusa Kazım Üçüncü
Musa Kazım Üçüncü
MUMerve Yildirim Ucuncu
Merve Yildirim Ucuncu
ZKZeynep Hale Keleş
Zeynep Hale Keleş
Background/Objectives: This study included first- to fifth-year dental students and aimed to compare dental anxiety levels using the Musa Kazım Dental Anxiety Scale (MK-DAS) and the Modified Dental Anxiety Scale (MDAS). Methods: A cross-sectional, web-based study was conducted at Altınbaş University Faculty of Dentistry (20–31 May 2024). A total of 200 students (40 per academic year) completed the 7-item MK-DAS (cut-off ≥ 17) and the 5-item MDAS (cut-off ≥ 15), and toothbrushing frequency was recorded. Between-year differences were assessed using Kruskal–Wallis tests with effect sizes (ε2). The association between academic year and anxiety scores was further evaluated using multivariable linear regression adjusted for age and gender. Concordance between scales was assessed using Spearman’s correlation. Statistical significance was set at α = 0.05. Results: Participants were 62.5% female (n = 125), with a mean age of 22.22 ± 2.08 years; 75.5% reported brushing twice daily. Anxiety scores differed significantly across academic years (MDAS: H = 39.05, ε2 = 0.184, p < 0.001; MK-DAS: H = 43.07, ε2 = 0.200, p < 0.001). Second-year students had the highest mean scores (MDAS: 14.08 ± 4.53; MK-DAS: 18.40 ± 4.83), whereas fourth-year students had the lowest MDAS scores (8.43 ± 3.37). High anxiety prevalence was 23.0% (MDAS) and 29.0% (MK-DAS). The scales were strongly correlated (Spearman’s ρ = 0.784, p < 0.001). Gender-related differences were significant only in second-year students. The association between academic year and anxiety scores remained significant after adjustment. Conclusions: Dental anxiety demonstrated a non-linear distribution across academic years, peaking in second-year students. MK-DAS showed strong concordance with MDAS. Findings should be interpreted cautiously given the cross-sectional, web-based design.

26 April 2024 in Selcuk Dental Journal
Verified
Journal Article
Open access
PDF file
ZKZeynep Hale Keleş
Zeynep Hale Keleş
BTBerna Tarım
Berna Tarım
Background: This study aims to evaluate the effect of preheating on microhardness, degree of conversion, and depth of cure of bulk-fill composites (Tetric EvoCeram Bulk-Fill, SonicFill2) and a conventional composite (Tetric EvoCeram). Methods: Layers of Tetric EvoCeram (2 mm), Tetric EvoCeram Bulk-Fill (4 mm), and SonicFill2 (5 mm) were placed in 4-mm diameter molds and polymerized at room temperature or heated to 55oC for 10 s with a total number of 60 samples. Then, the top surfaces of samples were polished. 30 samples’ Vickers microhardness was measured from the top and bottom surfaces. The other 30 samples were pulverized into a fine powder, and the composites’ degree of conversion was measured with attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy. Obtained data were analyzed statistically with a significance level of p<0.05. Results: The degree of conversion of Tetric EvoCeram was higher than the minimum rate of clinically acceptable value, which is 55%, but the scores of Tetric EvoCeram Bulk-Fill and SonicFill2 were below the threshold. Preheating increased the degree of conversion of Tetric EvoCeram Bulk-Fill and SonicFill2. In addition, preheating did not affect depth of cure of SonicFill2 but decreased the rate of Tetric EvoCeram Bulk-Fill. Conclusion: The results showed that the effect of preheating on the degree of conversion and depth of cure varied according to the material. Keywords: Preheating, bulk-fill composite, degree of conversion, depth of cure, microhardness.