Vsevolod Belousov

Vsevolod Belousov

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Cell Metabolism
Verified
Journal Article
Closed access
VPValeriy V. Pak
Valeriy V. Pak
DEDaria Ezeriņa
Daria Ezeriņa
OLOlga Lyublinskaya
Olga Lyublinskaya
BPBrandán Pedre
Brandán Pedre
Pyotr Tyurin-KuzminPyotr Tyurin-Kuzmin
Pyotr Tyurin-Kuzmin
VBVsevolod Belousov
Vsevolod Belousov

7 January 2013 in ACS Chemical Biology
Verified
Journal Article
Closed access
DBDmitry Bilan
Dmitry Bilan
LPLuke Pase
Luke Pase
LJLinda Joosen
Linda Joosen
AGAndrey Yu. Gorokhovatsky
Andrey Yu. Gorokhovatsky
YEYulia Ermakova
Yulia Ermakova
VBVsevolod Belousov
Vsevolod Belousov

21 October 2014 in Nature Communications
Verified
Journal Article
Open access
PDF file
YEYulia Ermakova
Yulia Ermakova
DBDmitry Bilan
Dmitry Bilan
MMMikhail E. Matlashov
Mikhail E. Matlashov
NMNatalia M. Mishina
Natalia M. Mishina
KMKsenia N. Markvicheva
Ksenia N. Markvicheva
VBVsevolod Belousov
Vsevolod Belousov
Reactive oxygen species (ROS) are conserved regulators of numerous cellular functions, and overproduction of ROS is a hallmark of various pathological processes. Genetically encoded fluorescent probes are unique tools to study ROS production in living systems of different scale and complexity. However, the currently available recombinant redox sensors have green emission, which overlaps with the spectra of many other probes. Expanding the spectral range of recombinant in vivo ROS probes would enable multiparametric in vivo ROS detection. Here we present the first genetically encoded red fluorescent sensor for hydrogen peroxide detection, HyPerRed. The performance of this sensor is similar to its green analogues. We demonstrate the utility of the sensor by tracing low concentrations of H2O2 produced in the cytoplasm of cultured cells upon growth factor stimulation. Moreover, using HyPerRed we detect local and transient H2O2 production in the mitochondrial matrix upon inhibition of the endoplasmic reticulum Ca2+ uptake.

Verified
Journal Article
Open access
PDF file
AKAlexander Kostyuk
Alexander Kostyuk
AKAleksandra Kokova
Aleksandra Kokova
DKDaria Kotova
Daria Kotova
VBVsevolod Belousov
Vsevolod Belousov
DBDmitry Bilan
Dmitry Bilan
Genetically encoded biosensors based on fluorescent proteins (FPs) are a reliable tool for studying the various biological processes in living systems. The circular permutation of single FPs led to the development of an extensive class of biosensors that allow the monitoring of many intracellular events. In circularly permuted FPs (cpFPs), the original N- and C-termini are fused using a peptide linker, while new termini are formed near the chromophore. Such a structure imparts greater mobility to the FP than that of the native variant, allowing greater lability of the spectral characteristics. One of the common principles of creating genetically encoded biosensors is based on the integration of a cpFP into a flexible region of a sensory domain or between two interacting domains, which are selected according to certain characteristics. Conformational rearrangements of the sensory domain associated with ligand interaction or changes in the cellular parameter are transferred to the cpFP, changing the chromophore environment. In this review, we highlight the basic principles of such sensors, the history of their creation, and a complete classification of the available biosensors.

22 October 2014 in Nature
Verified
Journal Article
Open access
PDF file
MSMarkus Schwarzländer
Markus Schwarzländer
SWStephan Wagner
Stephan Wagner
YEYulia Ermakova
Yulia Ermakova
VBVsevolod Belousov
Vsevolod Belousov
RRRafael Radi
Rafael Radi
MMMichael P. Murphy
Michael P. Murphy
Arising from E.-Z. Shen et al. Nature 508, 128–132 (2014); doi:10.1038/nature1301210.1038/nature13012 Ageing and lifespan of organisms are determined by complicated interactions between their genetics and the environment, but the cellular mechanisms remain controversial; several studies suggest that cellular energy metabolism and free radical dynamics affect lifespan, implicating mitochondrial function. Recently, Shen et al.1 provided apparent mechanistic insight by reporting that mitochondrial oscillations of ‘free radical production’, called ‘mitoflashes’, in the pharynx of three-day old Caenorhabditis elegans correlated inversely with lifespan. The interpretation of mitoflashes as ‘bursts of superoxide radicals’ assumes that circularly permuted yellow fluorescent protein (cpYFP) is a reliable indicator of mitochondrial superoxide2, but this interpretation has been criticized because experiments and theoretical considerations both show that changes in cpYFP fluorescence are due to alterations in pH, not superoxide3,4,5,6,7. Here we show that purified cpYFP is completely unresponsive to superoxide, and that mitoflashes do not reflect superoxide generation or provide a link between mitochondrial free radical dynamics and lifespan. There is a Reply to this Brief Communication Arising by Cheng, H. et al. Nature 514, http://dx.doi.org/10.1038/nature13859 (2014).

1 May 2016 in Antioxidants & Redox Signaling
Verified
Journal Article
Closed access
DBDmitry Bilan
Dmitry Bilan
VBVsevolod Belousov
Vsevolod Belousov
Significance: Hydrogen peroxide (H 2 O 2 ) is not only a key mediator of oxidative stress but also one of the most important cellular second messengers. This small short-lived molecule is involved in the regulation of a wide range of different biological processes, including regulation of cellular signaling pathways. Studying the role of H 2 O 2 in living systems would be challenging without modern approaches. A genetically encoded fluorescent biosensor, HyPer, is one of the most effective tools for this purpose. Recent Advances: HyPer has been used by many investigators of redox signaling in various models of different scales: from cytoplasmic subcompartments and single cells to tissues of whole organisms. In many studies, the results obtained using HyPer have enabled a better understanding of the roles of H 2 O 2 in these biological processes. However, much remains to be learned. Critical Issues: In this review, we focus on the uses of HyPer. We provide a general description of HyPer and its improved versions. Separate chapters are devoted to the results obtained by various groups who have used this biosensor for their experiments in living cells and organisms. Future Directions: HyPer is an effective tool for H 2 O 2 imaging in living systems as indicated by the increasing numbers of publications each year since its development. However, this biosensor requires further improvements. In particular, much brighter and more pH-stable versions of HyPer are necessary for imaging in mammalian tissues. Antioxid. Redox Signal. 24, 731–751.