Ziqiang Yuan

Dr. Ziqiang Yuan

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ZYZiqiang Yuan
Ziqiang Yuan
CWChen Wang
Chen Wang
YXYanzhang Xie
Yanzhang Xie
YZYingzi Zhang
Yingzi Zhang
WLWenYi Liu
WenYi Liu
Vector magnetometer arrays are essential for ferromagnetic target detection and MGT measurement, but their performance is limited by proportional factor errors, triaxial non-orthogonality, soft/hard iron interference, and inconsistent array orientations. Traditional rotation-based scalar calibration requires magnetic-free turntables or manual multi-orientation operations, introducing mechanical noise, orientation perturbations, and poor repeatability. This paper proposes an in situ rapid calibration method for MGT systems using triaxial Helmholtz coils. By generating three-dimensional magnetic field sequences of constant magnitude and random directions while keeping the sensors stationary, the method replaces conventional rotational excitation. A two-stage rapid calibration algorithm is developed to achieve individual sensor error modeling and array relative calibration. Experimental results show substantial improvements. The tensor invariant CT decreased from 6287.84 nT/m to 7.57 nT/m, with variance reduced from 1.46 × 106 to 13.47 nT2/m2; inter-sensor output differences were suppressed to 1–3 nT; and the magnetic field magnitude error dropped from ~940 nT to 3 × 10−4 nT, achieving a 5–6-order-of-magnitude enhancement. These results verify the method’s effectiveness in eliminating rotational errors, improving array consistency, and enabling high-precision in situ calibration with strong engineering value.

19 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CWChen Wang
Chen Wang
ZYZiqiang Yuan
Ziqiang Yuan
GLGaigai Liu
Gaigai Liu
YZYingzi Zhang
Yingzi Zhang
WLWenYi Liu
WenYi Liu
Accurate calibration is essential for ensuring the performance of magnetic gradient tensor (MGT) arrays. Existing calibration methods generally rely on mechanical rotation to obtain magnetic responses under multiple orientations. However, for large-scale cubic MGT arrays, rotating the entire array using a high-precision non-magnetic turntable is often costly and impractical, while manual rotation is difficult to control and may introduce array-center offsets. To address these limitations, this paper proposes a rotation-free scalar calibration framework for cubic MGT arrays, in which a tri-axial Helmholtz coil system generates constant-magnitude magnetic fields with randomized orientations while compensating for ambient magnetic drifts. Based on the acquired data, a hierarchical calibration algorithm is developed to estimate sensor-level intrinsic errors and array-level misalignment errors. Experimental results show that the proposed method reduces the joint tensor invariant CT from 9.07×103 nT/m to 11.51 nT/m, corresponding to a 99.87% reduction. In addition, compared with a conventional rotation-based fast calibration method, the proposed framework further decreases the mean and RMS of the joint CT by 62.7% and 63.1%, respectively. These results demonstrate that the proposed framework improves the spatial consistency of the MGT array and provides a practical calibration solution for large-scale MGT array systems.