Liqing Kang

Prof. Dr. Liqing Kang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
JLJunzhong Liu
Junzhong Liu
XWXinhua Wang
Xinhua Wang
YWYongming Wang
Yongming Wang
MSMinfeng Sun
Minfeng Sun
CLChangsheng Liang
Changsheng Liang
LKLiqing Kang
Liqing Kang
Objective: To compare two kinds of metal markers for preoperative localization of ground glass nodules (GGNs). Methods: We retrospectively investigated data from 198 cases of GGN localization and compared the success rate and complications of both approaches. Results: In the hook wire and coil groups, the success rates of CT-guided localization for GGNs were 99.2 and 98.7%, respectively (p = 1.000). The success rates of video-assisted thoracoscopic surgery in both groups were 100% without transthoracic surgery. The post-localization complication rates in the hook wire group and coil group were 36.9 and 32.9% (p = 0.568), and the postoperative complication rates in the hook wire and coil groups were 13.9 and 11.8%, respectively (p = 0.672). Conclusions: Preoperative localization of GGNs with both hook wire and coil methods proved to be useful and effective. Both methods have acceptable preoperative and postoperative complication rates, but the localization and operation times were shorter for the hook wire group than the coil group. Advances in knowledge: Most of previous articles studied a single preoperative localization method. Few studies have compared the preoperative and postoperative methods for metal markers. This paper compared two preoperative localization methods for GGNs to provide clinical guidance.

27 July 2020 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
YZYing Zhang
Ying Zhang
SYShujing Yu
Shujing Yu
LZLi Zhang
Li Zhang
LKLiqing Kang
Liqing Kang
Background: Kimura disease may be easily misdiagnosed as malignant tumors such as lymph node metastases based on imaging and clinical symptoms. The aim of this article is to investigate whether the radiomic features and the model based on the features on venous-phase contrast-enhanced CT (CECT) images can distinguish Kimura disease from lymph node metastases in the head and neck. Methods: A retrospective analysis of 14 patients of head and neck Kimura disease (a total of 38 enlarged lymph nodes) and 39 patients with head and neck lymph node metastases (a total of 39 enlarged lymph nodes), confirmed by biopsy or surgery resection, was conducted. All patients accepted CECT within 10 days before biopsy or surgery resection. Radiomic features based on venous-phase CECT were generated automatically from Artificial-Intelligence Kit (AK) software. All lymph nodes were randomly divided into the training set (n = 54) and testing set (n = 23) in a ratio of 7:3. ANOVA + Mann–Whitney, Spearman correlation, least absolute shrinkage and selection operator, and Gradient Descent were introduced for the reduction of the highly redundant features. Binary logistic regression model was constructed based on the selected features. Receiver operating characteristic was used to evaluate the diagnostic performance of the features and the model. Finally, a nomogram was established for model application. Results: Seven features were screened out at the end. Significant difference was found between the two groups for all the features with area under the curves (AUCs) ranging from 0.759 to 0.915. The AUC of the model's identification performance was 0.970 in the training group and 0.977 in the testing group. The disease discrimination efficiency of the model was better than that of any single feature. Conclusions: The radiomic features and the model based on these features on venous-phase CECT images had very good performance for the discrimination between Kimura disease and lymph node metastases in the head and neck.

18 May 2022 in Disease Markers
Verified
Journal Article
Open access
PDF file
CWChao Wang
Chao Wang
QWQirong Wang
Qirong Wang
XZXuemei Zhao
Xuemei Zhao
XWXia Wang
Xia Wang
WZWenji Zhou
Wenji Zhou
LKLiqing Kang
Liqing Kang
Objective. To evaluate the effects of different delivery modes on pelvic floor function in parturients 6–8 weeks after delivery using transperineal four-dimensional ultrasound. Methods. Pelvic floor function 6–8 weeks after delivery in 40 vaginal delivery parturients between November 2018 and December 2020 was assessed by four-dimensional ultrasound, with 40 selective cesarean section delivery parturients as a control group. The imaging results of the two groups were compared. Results. The levels of clinical indexes such as UVJ-M, , , θ, , , and ARJ-VDv in the selective cesarean section group were significantly lower than those in the vaginal delivery group 6–8 weeks after delivery ( ). However, no significant difference in CV-VD was observed under Valsalva action and at rest between the two groups ( ). No significant difference in ARJ-VD was found at rest between the two groups ( ). The incidence of pelvic organ prolapse in the selective cesarean section group (40.0%) was significantly lower than that in the vaginal delivery group (62.5%) ( ). No significant difference in the parameters of pelvic diaphragm hiatus at rest was observed between the two groups ( ). The parameters of pelvic diaphragm hiatus under maximum Valsalva action in the vaginal delivery group were significantly higher than those in the selective cesarean section group ( ). Whether the patient was complicated with diabetes had no significant effect on the functional injury of pelvic floor muscle ( ). Conclusion. The pelvic floor function 6–8 weeks after delivery was significantly more affected in vaginal delivery than in selective cesarean section. Selective cesarean section had certain but limited protective effect on maternal pelvic floor tissue.

5 November 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
JLJunzhong Liu
Junzhong Liu
CLChangsheng Liang
Changsheng Liang
XWXinhua Wang
Xinhua Wang
MSMinfeng Sun
Minfeng Sun
LKLiqing Kang
Liqing Kang
Objective: To develop and validate a CT-based nomogram to predict the occurrence of loculated pneumothorax due to hook wire placement. Methods: Patients (n = 177) were divided into pneumothorax (n = 72) and non-pneumothorax (n = 105) groups. Multivariable logistic regression analysis was applied to build a clinical prediction model using significant predictors identified by univariate analysis of imaging features and clinical factors. Receiver operating characteristic (ROC) was applied to evaluate the discrimination of the nomogram, which was calibrated using calibration curve. Results: Based on the results of multivariable regression analysis, transfissure approach [odds ratio (OR): 757.94; 95% confidence interval CI (21.20–27099.30) p < 0.0001], transemphysema [OR: 116.73; 95% CI (12.34–1104.04) p < 0.0001], localization of multiple nodules [OR: 8.04; 95% CI (2.09–30.89) p = 0.002], and depth of nodule [OR: 0.77; 95% CI (0.71–0.85) p < 0.0001] were independent risk factors for pneumothorax and were included in the predictive model (p < 0.05). The area under the ROC curve value for the nomogram was 0.95 [95% CI (0.92–0.98)] and the calibration curve indicated good consistency between risk predicted using the model and actual risk. Conclusion: A CT-based nomogram combining imaging features and clinical factors can predict the probability of pneumothorax before localization of ground-glass nodules. The nomogram is a decision-making tool to prevent pneumothorax and determine whether to proceed with further treatment. Advances in knowledge: A nomogram composed of transfissure, transemphysema, multiple nodule localization, and depth of nodule has been developed to predict the probability of pneumothorax before localization of GGNs.

20 April 2022 in Research Square
Verified
Preprint
Open access
PDF file
HZHouning Zhang
Houning Zhang
JSJiaxi Sheng
Jiaxi Sheng
GLGuoce Li
Guoce Li
FLFenghai Liu
Fenghai Liu
HBHao Bian
Hao Bian
LKLiqing Kang
Liqing Kang
The purpose of this article is to investigate the value of cardiac magnetic resonance imaging (CMR) derived left ventricular strain parameters in evaluation of ischemic cardiomyopathy (ICM). Thirty-one ICM patients and nineteen non-cardiomyopathy (non-CM) patients who performed CMR examinations during the same period were selected for this retrospective study. The basic clinical data, CMR left ventricular function parameters, left ventricular strain parameters were compared among the left ventricular ejection fraction (LVEF) preserved ICM group, the LVEF impaired ICM group and the non-CM group. The differences of MyoGCS (-21.9 ± 1.9 vs -18.9 ± 2.7 P<0.001), MyoGLS (-20.8 ± 2.3 vs -17.0 ± 2.9 P<0.001) and EndoGLS (-22.2 ± 3.1 vs -17.6 ± 3.7 P 0.05). The left ventricular strain analysis can be used to assess cardiac functional and morphological alterations in ICM patients prior to changes of left ventricular function parameters, which has high clinical significance.

11 October 2025 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
BZBin Zhang
Bin Zhang
FLFenghai Liu
Fenghai Liu
GLGuoce Li
Guoce Li
JLJing Liang
Jing Liang
FYFan Yang
Fan Yang
LKLiqing Kang
Liqing Kang