Wanlin Cao

Dr. Wanlin Cao


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Engineering Structures
Verified
Journal Article
Closed access
HDHongying Dong
Hongying Dong
YLYanna Li
Yanna Li
WCWanlin Cao
Wanlin Cao
QQQiyun Qiao
Qiyun Qiao
RLRuijian Li
Ruijian Li

1 July 2019 in Construction and Building Materials
Verified
Journal Article
Closed access
HDHongying Dong
Hongying Dong
YSYu Song
Yu Song
WCWanlin Cao
Wanlin Cao
WSWenjuan Sun
Wenjuan Sun
JZJianwei Zhang
Jianwei Zhang

8 December 2014 in Materials
Verified
Journal Article
Open access
PDF file
HDHongying Dong
Hongying Dong
WCWanlin Cao
Wanlin Cao
JBJianhui Bian
Jianhui Bian
JZJianwei Zhang
Jianwei Zhang
In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete’s compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength.

9 March 2017 in Materials
Verified
Journal Article
Open access
PDF file
WLWenchao Liu
Wenchao Liu
WCWanlin Cao
Wanlin Cao
JZJianwei Zhang
Jianwei Zhang
RWRuwei Wang
Ruwei Wang
LRLele Ren
Lele Ren
Recycled aggregate concrete (RAC) is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST) columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens were subjected to axial compression tests at room temperature and the other six specimens were subjected to axial compression tests after a fire exposure. The main parameters of the specimens include the wall thickness of the steel tube (steel content) and the type of concrete materials. Several parameters as obtained from the experimental results were compared and analyzed, including the load-bearing capacity, deformation capacity, and failure characteristics of the specimens. Meanwhile, rate of loss of bearing capacity of specimens exposed to fire were calculated based on the standards EC4 and CECS28:90. The results show that concrete material has a large influence on the rate of loss of bearing capacity in the case of a relatively lower steel ratio. While steel content has little effect on the rate of loss of bearing capacity of concrete-filled steel tube (CFST) columns after fire, it has a relatively large influence on the loss rate of bearing capacity of the RACFST columns. The loss of bearing capacity of the specimens from the experiment is more serious than that from the calculation. As the calculated values are less conservative, particular attention should be given to the application of recycled aggregate concrete in actual structures.

31 May 2014 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
JZJianwei Zhang
Jianwei Zhang
WCWanlin Cao
Wanlin Cao
SMShaobin Meng
Shaobin Meng
CYCheng Yu
Cheng Yu
HDHongying Dong
Hongying Dong

1 December 2011 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
WCWanlin Cao
Wanlin Cao
JZJianwei Zhang
Jianwei Zhang
HDHongying Dong
Hongying Dong
MWMin Wang
Min Wang