Serkan Duyuler

Prof. Dr. Serkan Duyuler

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2017 in Journal of Clinical Laboratory Analysis
Verified
Journal Article
Closed access
PDF file
AKAhmet Korkmaz
Ahmet Korkmaz
AYAbdulkadir Yıldız
Abdulkadir Yıldız
PDPınar Türker Duyuler
Pınar Türker Duyuler
SDSerkan Duyuler
Serkan Duyuler
SYSamet Yılmaz
Samet Yılmaz
MIMehmet Ileri
Mehmet Ileri

6 December 2021 in Acta Cardiologica
Verified
Journal Article
Closed access
PDPınar Turker Duyuler
Pınar Turker Duyuler
SDSerkan Duyuler
Serkan Duyuler
BDBekir Demirtaş
Bekir Demirtaş
VÇVelihan Çayhan
Velihan Çayhan
To investigate the association between epicardial and pericoronary adipose tissue thicknesses measured with computed tomography (CT) and severity of COVID-19 infection.We recruited 504 patients adm...

1 June 2013 in Acta Cardiologica
Verified
Journal Article
Closed access
AKAhmet Korkmaz
Ahmet Korkmaz
SDSerkan Duyuler
Serkan Duyuler
SKSüleyman Kalayci
Süleyman Kalayci
PTPɪnar Türker
Pɪnar Türker
E¸Ekrem ¸sAhan
Ekrem ¸sAhan
MSMehmet Timur Selçuk
Mehmet Timur Selçuk
Objective Iatrogenic femoral pseudoaneurysm is a well-known vascular access site complication. Many invasive and noninvasive techniques have been proposed for the management of this relatively common complication. In this study, we aimed to evaluate effi ciency and safety of stethoscopeguided compression as a novel noninvasive technique in the femoral pseudoaneurysm treatment. Methods and results We prospectively included 29 consecutive patients with the diagnosis of femoral pseudoaneurysm who underwent coronary angiography. Patients with a clinical suspicion of femoral pseudoaneurysm were referred to colour Doppler ultrasound evaluation. The adult (large) side of the stethoscope was used to determine the location where the bruit was best heard. Then compression with the paediatric (small) side of the stethoscope was applied until the bruit could no longer be heard and compression was maintained for at least two sessions. Once the bruit disappeared, a 12-hour bed rest with external elastic compression was advised to the patients, in order to prevent disintegration of newly formed thrombosis. Mean pseudoaneurysm size was 1.7 ± 0.4 cm × 3.0 ± 0.9 cm and the mean duration of compression was 36.2 ± 8.5 minutes. Twenty-six (89.6%) of these 29 patients were successfully treated with stethoscope-guided compression. In 18 patients (62%), the pseuodoaneurysms were successfully closed after 2 sessions of 15-minute compression. No severe complication was observed. Conclusion Stethoscope-guided compression of femoral pseudoaneurysms is a safe and eff ective novel technique which requires less equipment and expertise than other contemporary methods.

1 January 2018 in Coronary Artery Disease
Verified
Journal Article
Closed access
PDF file
PDPinar Türker Duyuler
Pinar Türker Duyuler
SDSerkan Duyuler
Serkan Duyuler
MGMurat Gök
Murat Gök
HKHarun Kundi
Harun Kundi
CTCanan Topçuoğlu
Canan Topçuoğlu
ÜGÜmit Güray
Ümit Güray
ObjectivesElucidation of the underlying mechanisms of angiogenesis and arteriogenesis in coronary collateral formation is necessary for new therapies. Pleiotrophin is a secreted multifunctional cytokine and associated with the formation of functional cardiovascular neovascularization in a series of experimental animal models. We aimed to evaluate the serum levels of pleiotrophin in patients with chronic total coronary artery occlusion and poor or good collateral development.MethodsWe included 88 consecutive patients (mean age of the entire population: 63.712.1 years, 68 male patients) with stable angina pectoris who underwent coronary angiography and had chronic total occlusion in at least one major coronary artery. Collateral grading was performed according to the Rentrop classification. After grading, patients were divided into poor collateral circulation (Rentrop grade 0 and 1) and good collateral circulation (Rentrop grades 2 and 3) groups. Serum pleiotrophin levels were measured using a commercial human ELISA kit.ResultsFifty-eight patients had good and 30 patients had poor coronary collaterals. The good collateral group had higher serum pleiotrophin levels than the poor collateral group (690.1 +/- 187.9 vs. 415.3 +/- 165.9ng/ml, P<0.001). Pleiotrophin levels were higher with higher Rentrop grade (P<0.001). In multivariate analysis, increased pleiotrophin was associated independently with good collateral development (odds ratio: 1.007; confidence interval: 1.003-1.012; P=0.002).ConclusionThis study showed that increased serum pleiotrophin levels are associated with better developed coronary collateral circulation. Further studies are needed to better understand the relationship.

1 December 2017 in Blood Pressure Monitoring
Verified
Journal Article
Closed access
PDPinar Türker Duyuler
Pinar Türker Duyuler
SDSerkan Duyuler
Serkan Duyuler
MDMevlüt Demir
Mevlüt Demir
ÖEÖzgül Uçar Elalmiş
Özgül Uçar Elalmiş
ÜGÜmit Güray
Ümit Güray
MIMehmet İlEri
Mehmet İlEri
Objective Exaggerated blood pressure response to exercise is a risk factor for the development of future hypertension. In this study, we aimed to investigate the association between homocysteine, epicardial fat thickness, nonalcoholic hepatic steatosis, and exaggerated blood pressure response to exercise. Participants and methods We included 44 normotensive and 40 patients with exaggerated blood pressure response to exercise who have normal resting blood pressure and without a previous diagnosis of hypertension. All patients underwent treadmill exercise test and clinical, ultrasonographic, and echocardiographic evaluation. Exaggerated blood pressure response to exercise is defined as peak exercise systolic blood pressure of at least 210 mmHg in men and at least 190 mmHg in women. Homocysteine and other biochemical parameters were determined with standardized automated laboratory tests. Results Mean age of all participants is 47.9±8.5 years, and 36 of 84 participants were female. The frequency of diabetes mellitus in both groups was similar (P=0.250). Homeostasis model assessment index–insulin resistance had a statistically insignificant trend to be higher in a patient with exercise hypertension (P=0.058). The nonalcoholic fatty liver was more frequent in patients with exercise hypertension (13.6 vs. 47.5%, P=0.002). Epicardial fat thickness was increased in patients with exercise hypertension (5.5±1.5 vs. 7.3±1.1 mm; P=0.001). However, homocysteine levels did not significantly differ between normotensive and exercise hypertensive patients [12.3 μmol/l (5.7–16.9 μmol/l) vs. 13 μmol/l (5.9–28.3 μmol/l); P=0.883]. Conclusion In our study, homocysteine levels were not associated with exaggerated blood pressure response to exercise; however, fatty liver and epicardial fat thickness as visceral adiposity-related cardiometabolic risk factors were significantly related with exaggerated blood pressure response to exercise in patients without a previous diagnosis of hypertension.

25 April 2022 in International Journal of Obesity
Verified
Journal Article
Closed access
PDF file
SDSerkan Duyuler
Serkan Duyuler
PDPınar Türker Duyuler
Pınar Türker Duyuler