Shelishiyah Raymond

Dr. Shelishiyah Raymond

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MVMozhi Vendhan V
Mozhi Vendhan V
SASiva Sailesh Appuswamy
Siva Sailesh Appuswamy
MAMohammed Shakeel Haneef Asfer
Mohammed Shakeel Haneef Asfer
PTPrakash Thiruvengadam
Prakash Thiruvengadam
SKSamyuktha Dinesh Kumar
Samyuktha Dinesh Kumar
SRShelishiyah Raymond
Shelishiyah Raymond
Individuals with visual impairments face major challenges in navigation, obstacle recognition, and social interaction. This paper presents the design, development, and testing of a pair of glass-mounted smart vision glasses (SVG) intended to assist visually impaired users through real-time environmental sensing and feedback. The wearable device is built around an Arduino Nano microcontroller together with a Grove Ultrasonic Sensor, an active buzzer, and a vibration motor, providing combined auditory and haptic obstacle alerts. The ultrasonic sensor detects obstacles by emitting ultrasonic pulses and measuring the backscattered echo signal; whenever an obstacle is found within a predefined range, the buzzer and vibration motor are triggered simultaneously to warn the user, helping to prevent collisions. The complete device weighs approximately 100 g and is powered by a rechargeable battery fitted with a boost converter. The prototype was benchmarked over obstacle distances of 20 mm to 80 mm to evaluate its accuracy, response time, and reliability. Results show a response time of 0.33 s to 0.53 s, a percentage error of 0.7% to 1.4%, and an overall accuracy of 98.6% to 99.3%, with the best accuracy obtained at the 20 mm distance. These results indicate that the proposed smart glasses can provide an effective, reliable, and affordable navigation aid that meaningfully improves the quality of life of visually impaired users.

7 November 2025 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SGSudarsun G
Sudarsun G
GNGlen Nitish
Glen Nitish
DFDANIEL FORD
DANIEL FORD
DTDeepa Beeta Thiyam
Deepa Beeta Thiyam
SRShelishiyah Raymond
Shelishiyah Raymond
In pharmaceutical and biomedical industries, manual handling of dangerous chemicals is a leading cause of hazardous exposure to chemicals, toxic burning, and chemical contamination. To counteract these risks, we proposed a gesture-controlled bionic hand system to mimic human finger movements for safe and contactless chemical handling. This innovation system uses an ESP32 microcontroller to decode the hand gestures that are detected by the system using computer vision via an integrated camera. A PWM servo driver converts these movements to motor commands such that accurate movements of the fingers can be achieved. Teflon and other corrosion-proof materials are utilized in the 3D printing of the bionic hand in order to withstand corrosive conditions. This new, low-cost, and non-surgical approach replaces the EMG sensors, gives real-time control, and enhances industrial and laboratory process safety. The project is a major milestone in the application of robotics and AI for automation and risk reduction in dangerous environments.

26 October 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
APALVIN PAUL
ALVIN PAUL
KRKashinath Raj
Kashinath Raj
SRShelishiyah Raymond
Shelishiyah Raymond
Assessing how well-hydrated the outer layer of skin is has really become crucial. This paper proposes a compact, wearable device that monitors surface hydration in real-time by using the Galvanic Skin Response as the main electrical signal, with a flex sensor that supports the mechanical stretchability of the skin. An AD620 instrumentation amplifier boosts the raw GSR signal before it is digitized through the ESP32’s 12-bit ADC. Based on ADC values, which are calibrated experimentally across different skin conditions, the device classifies into three sections—dry, normal and highly hydrated. An alert system is incorporated in the system when dry skin is detected.