The determination of the relationship between skin blood flow and skin temperature dynamics is the main problem in thermography-based blood flow imaging. Oscillations in skin blood flow are the source of thermal waves propagating from micro-vessels toward the skin’s surface, as assumed in this study. This hypothesis allows us to use equations for the attenuation and dispersion of thermal waves for converting the temperature signal into the blood flow signal, and vice versa. We developed a spectral filtering approach (SFA), which is a new technique for thermography-based blood flow imaging. In contrast to other processing techniques, the SFA implies calculations in the spectral domain rather than in the time domain. Therefore, it eliminates the need to solve differential equations. The developed technique was verified within 0.005–0.1 Hz, including the endothelial, neurogenic and myogenic frequency bands of blood flow oscillations. The algorithm for an inverse conversion of the blood flow signal into the skin temperature signal is addressed. The examples of blood flow imaging of hands during cuff occlusion and feet during heating of the back are illustrated. The processing of infrared (IR) thermograms using the SFA allowed us to restore the blood flow signals and achieve correlations of about 0.8 with a waveform of a photoplethysmographic signal. The prospective applications of the thermography-based blood flow imaging technique include non-contact monitoring of the blood supply during engraftment of skin flaps and burns healing, as well the use of contact temperature sensors to monitor low-frequency oscillations of peripheral blood flow.
It is well established that skin temperature oscillations in fingertips coexist with blood flow oscillations and there is a certain correlation between them. At the same time, the reasons for differences in waveform and the delay between the blood flow and temperature oscillations are far from being fully understood. In this study we determine the relationships between spectral components of the blood flow and temperature oscillations in fingertips, and we ascertain the frequency dependences of amplitude attenuation and delay time for the temperature oscillations. The blood flow oscillations were considered as a source of thermal waves propagating from micro-vessels towards the skin surface and manifesting as temperature oscillations. The finger temperature was measured by infrared thermography and blood flow was assessed by photoplethysmography for ten healthy subjects. The time-frequency analysis of oscillations was based on the Morlet wavelet transform. The frequency dependences of delay time and amplitude attenuation in temperature compared with blood flow oscillations have been determined in endothelial (0.005-0.02 Hz) and neurogenic (0.02-0.05 Hz) frequency bands using the wavelet spectra. We approximated the experimental frequency dependences by equations describing thermal wave propagation through the medium and taking into account the thermal properties and thickness of a tissue. Results of analysis show that with the increase of frequency f the delay time of temperature oscillations decreases inversely proportional to f(1/2), and the attenuation of the amplitude increases directly proportional to exp f(1/2). Using these relationships allows us to increase correlation between the processed temperature oscillations and blood flow oscillations from 0.2 to 0.7 within the frequency interval 0.005-0.05 Hz. The established experimental and theoretical relationships clarify an understanding of interrelation between the dynamics of blood flow and skin temperature, and define possibilities and limitations of temperature measurements as a method of blood flow assessment in extremities.
13 May 2019 in Computer Methods in Biomechanics and Biomedical Engineering
Monitoring of skin blood flow oscillations related with mechanical activity of vessels is a very useful modality during diagnosis of peripheral hemodynamic disorders. In this study, we developed a new model and technique for real-time conversion of skin temperature into skin blood flow oscillations, and vice versa. The technique is based on the analogy between the thermal properties of the human skin and electrical properties of the special low-pass filter. Analytical and approximated impulse response functions for the low- and high-pass filters are presented. The general algorithm for the reversible conversion of temperature into blood flow is described. The proposed technique was verified using simulated or experimental data of cold stress, deep inspiratory gasp, and post-occlusive reactive hyperaemia tests. The implementation of the described technique will enable to turn a temperature sensor into a blood flow sensor.
Interrelation of skin temperature and blood flow oscillations of fingers under normal conditions in healthy subjects has been investigated. Oscillations of a blood flow were measured by means of photoplethysmography; oscillations of a temperature were registered by means of thermal imaging camera. The method of blood flow reconstruction by temperature oscillations with the use of the Pennes bioheat transfer equation and a definition of delay time of a temperature in relation to blood flow signal has been described. Temperature oscillations have a lag in relation to blood flow oscillations of approximately 10-20 seconds. Delay time of temperature waves can be used for the definition of an effective thickness of a tissue layer separating blood vessels and skin surface. Use of the described technique of comparison of finger blood flow and temperature oscillations allows to raise correlation coefficient of the signals from 0.35 to 0.63 on average, which testifies of high degree of conditionality of temperature oscillations by blood flow oscillations. The considered method of non-contact restoration of blood flow oscillations by means of temperature oscillation measurements might find practical application in skin thermal lesions research, research of influence of physical and chemical factors on a skin microcirculation.
The review of recent papers devoted to actively developing methods of photoplethysmographic imaging (the PPGI) of blood volume pulsations in vessels and non-contact two-dimensional oximetry on the surface of a human body has been carried out. The physical fundamentals and technical aspects of the PPGI and oximetry have been considered. The manifold of the physiological parameters available for the analysis by the PPGI method has been shown. The prospects of the PPGI technology have been discussed. The possibilities of non-contact determination of blood oxygen saturation SpO2 (pulse saturation O2) have been described. The relevance of remote determination of the level of oxygenation in connection with the spread of a new coronavirus infection SARS-CoV-2 (COVID-19) has been emphasized. Most of the works under consideration cover the period 2010–2021.