The formation process of membrane fouling is complex and diverse, which is an important problem that needs to be overcome in membrane applications. In this paper, three foulant systems consisting of humic acid, humic acid plus Ca2+ and humic acid plus Ca2+ plus yeast were selected to compare membrane fouling processes with different aeration intensities. The aim was to establish the quantitative relationship between membrane fouling rate and shear stress, respectively, in a large-scale flat sheet MBR (FSMBR). The shear stress values at different aeration intensities were obtained using computational fluid dynamics (CFD). The membrane fouling rate during the filtration of different substances was measured by performing experiments. The comparison results showed that the membrane fouling rate varied greatly during the filtration of different substances. With the help of particle size distribution, the effect of different shear forces on floc size was further explored. Using the dual control of fouling rate and floc size, the recommended aeration intensity was 6~8 L/(m2·min).
A new concept of dynamic phase change material (PCM) wall structure in building envelope is proposed to enhance the passive solar energy utilization, in which PCM wall position could be exchanged with insulation layer. The thermal performance of phase change materials in buildings is related to many factors. To ensure that the novel dynamic PCM wall structure could reach its full potential, the thermal performance of the structure was numerically simulated and optimized based on different climatic conditions, room sizes and the position of PCM layer in the wall. The results indicated that the suitable PCM was different when using the novel dynamic PCM wall in different climates. Among the four cities of Harbin, Tianjin, Jinan and Guangzhou, northern cities, like Tianjin, were more suitable for using PCM A16 than southern cities. In terms of room size design, when the volume of the room remained identical, the room size design formed a certain correlation with the indoor temperature. In addition, results showed that the location of the novel PCM wall system in the wall would cause a great difference in indoor temperature, which was related to heat dissipation at different locations.
16 December 2024 in Industrial & Engineering Chemistry Research
This study proposes an innovative spacer design for use in spiral-wound membrane filtration systems as a high-performance alternative to conventional woven spacers. By eliminating interwoven filaments, this structure fundamentally reshapes flow patterns while maintaining mechanical support. A novel aspect of this methodology is the inaugural application of coupled computational fluid dynamics (CFD) and the discrete phase model (DPM) for modeling microbial particle transport and deposition dynamics, which has been a critical gap in prior studies that focused solely on hydrodynamic analysis without addressing biocolloid dynamics. Numerical simulations demonstrated that the novel design reduces stagnant zones by a significant amount compared to standard woven spacers and achieves a greater velocity uniformity. For all eight configurations of the novel design, the DPM-derived microbial distribution maps revealed a reduction of circa 65% in particle colonization density on the spacer surface, and this reaches a 77% reduction for the optimal design. These measurements directly linking structural geometry to antifouling efficacy provide mechanistic insight unattainable through conventional velocity field analysis alone. Experimental validation using optical coherence tomography (OCT) revealed a 40% reduction in TOC deposition, while confocal laser scanning microscopy (CLSM) quantified a 54% decrease in biofilm viability through adenosine triphosphate (ATP) measurements. The incorporation of the optimal spacer in the plate-and-frame test module demonstrated that the lower degree of fouling caused both a 23% increase in permeation flux together with 76% lower energy consumption compared to the commercial design.
27 June 2025 in ACS Applied Materials & Interfaces