Zekun Pang

Mr. Zekun Pang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2024 in Medicine
Verified
Journal Article
Open access
FZFukai Mm Zhao
Fukai Mm Zhao
YCYue Mm Chen
Yue Mm Chen
JZJiaming Me Zhao
Jiaming Me Zhao
ZPZekun Pang
Zekun Pang
JWJiao Wang
Jiao Wang
JLJianming Li
Jianming Li
The influence of computed tomography attenuation correction (CTAC) on the accuracy of diagnosing viable myocardium using Tc-99m-MIBI dedicated cardiac cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) combined with F-18-FDG Positron Emission Tomography/Computed Tomography (PET/CT) metabolic imaging, compared with conventional SPECT MPI, remains to be fully elucidated. To evaluate the impact of CTAC on the accuracy of diagnosing viable myocardium using Tc-99m-MIBI dedicated cardiac CZT SPECT MPI combined with F-18-FDG PET/CT, compared to conventional SPECT MPI. 193 patients underwent CZT SPECT and F-18-FDG PET/CT imaging, while 39 patients underwent conventional SPECT and F-18-FDG PET/CT imaging, with both groups utilizing CT for attenuation correction. The injured myocardium (hibernating and scarring) was quantified using the Q.PET software. After CTAC, both groups showed significant improvements in perfusion of the injured myocardial areas, particularly in the inferior wall (INF). The reduction in perfusion was more notable in the CZT SPECT group than that in the conventional group, particularly in the inferior and lateral walls. Among patients with large cardiac chambers, those undergoing MPI with CZT, with normal weights, or males, hibernating myocardium (HM) and scar post-CTAC reductions were particularly significant in the INF. If HM ≥ 10% is considered an indicator for recommended revascularization, among the 87 patients without prior cardiac bypass, 25 (28.7%) might not require revascularization treatment. Dedicated cardiac CZT SPECT and conventional SPECT MPI combined with F-18-FDG PET/CT significantly influenced the assessment of viable myocardium. The impact of CTAC was more profound in dedicated cardiac CZT SPECT, particularly in the INF region. CTAC significantly enhances the accuracy of viable myocardial assessment and may influence clinical decisions regarding revascularization therapy. Therefore, CTAC should be routinely used in dedicated cardiac CZT SPECT MPI combined with F-18-FDG PET/CT for myocardial viability diagnosis.


27 September 2024 in Medicine
Verified
Journal Article
Open access
YCYue Chen
Yue Chen
ZPZekun Pang
Zekun Pang
JWJiao Wang
Jiao Wang
XYXuewen Yang
Xuewen Yang
JLJianming Li
Jianming Li
We compared and analyzed the consistency and repeatability of left and right ventricular ((LV/RV) functions obtained by gated-equilibrium radionuclide ventriculography (ERNV) with cadmium–zinc–telluride single-photon emission computed tomography (CZT-SPECT) and conventional SPECT (C-SPECT) with sodium iodide crystal detectors. Seventy-seven patients were included in the retrospective study. Both C-SPECT and CZT-SPECT imaging were performed on the same day. Correlations and differences in LV/RV ejection fraction (LVEF and RVEF), peak ejection rate (PER), and peak filling rate (PFR) were compared between the 2 models. Cardiac magnetic resonance (CMR) was partially used as the gold standard, and ultrasound results were included for comparative analysis. Interobserver reproducibility of each parameter obtained by the 2 cameras was compared. Between the 2 cameras, there were no significant difference in LVEF, LVPER, LVPFR, and RVPER (P > .05) and there were in RVEF and RVPFR (P < .05 or .001). The correlations (R value) were 0.831 (LVEF, excellent), 0.619 (RVEF, good), 0.672 (LVPER, good), 0.700 (LVPFR, good), 0.463 (RVPER, normal), and 0.253 (RVPFR, poor). There were no significant difference between CMR and CZT-SPECT in LVEF (P > .05) while there were between CMR and both C-SPECT and ultrasound (P < .05). The correlations were all good (R = 0.660, 0.658, and 0.695). There were no significant difference between CMR and both C-SPECT and CZT-SPET in RVEF (P > .05) and the correlations were good (R = 0.771 and 0.745). For repeatability, the intraclass correlation coefficient of RVPFR by C-SPECT was good (intraclass correlation coefficient = 0.698) and excellent for the rest of the groups (0.823–0.989). The repeatability of LVEF and RVEF was better for CZT-SPECT than for C-SPECT. The repeatability of PER was better for both cameras than PFR. CZT-SPECT tomographic ERNV correlated well with C-SPECT planar ERNV in evaluation of biventricular systolic function and LV diastolic function. Compared with the “gold standard” CMR, both models had good correlation in measuring LV/RVEF. CZT-SPECT had better inter-group reproducibility than C-SPECT. The accuracy of RV diastolic function need further study. CZT-SPECT tomographic ERNV will play an important and unique role in the clinical application of accurate evaluation of biventricular function in the future.

28 April 2026 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
ACAjay Kumar Chaudhary
Ajay Kumar Chaudhary
FZFukai Zhao
Fukai Zhao
ZPZekun Pang
Zekun Pang
JLJianming Li
Jianming Li
Dynamic myocardial perfusion imaging (MPI) with cadmium-zinc-telluride (CZT) cardiac-dedicated single-photon emission computed tomography (SPECT) enables t

15 May 2026 in Medicine
Verified
Journal Article
Open access
YSYudong Shi
Yudong Shi
FZFukai Zhao
Fukai Zhao
ZPZekun Pang
Zekun Pang
YCYue Chen
Yue Chen
JWJiao Wang
Jiao Wang
JLJianming Li
Jianming Li
Quantitative myocardial blood flow (MBF) assessment using cardiac-dedicated cadmium-zinc-telluride (CZT) single photon emission computed tomography (SPECT) has emerged as a promising noninvasive approach for evaluating both macrovascular and microvascular coronary function. However, the reliability and comparability of MBF measurements are substantially influenced by variations in post-processing methodologies, including the application of attenuation correction (AC) and scatter correction (SC) techniques. Despite the increasing clinical adoption of CZT-SPECT for absolute perfusion quantification, systematic evaluations comparing different post-processing strategies remain limited. This study aimed to evaluate the impact of various post-processing approaches on absolute quantitative MBF measurements obtained through CZT-SPECT, with particular focus on AC and SC methodologies. Seventy patients who underwent dynamic CZT-SPECT myocardial perfusion imaging were retrospectively included, comprising 35 Tc-99m-methoxyisobutylisonitrile patients and 35 Tc-99m-tetrofosmin patients. Each raw imaging dataset was independently reprocessed using Corridor 4DM under 3 correction strategies – no correction, attenuation correction, and attenuation + scatter correction (ACSC) – as well as using MyoFlowQ. Repeated-measures analysis of variance or Friedman tests with Holm-adjusted pairwise comparisons were used to compare the Corridor 4DM processing strategies, and agreement between Corridor 4DM with ACSC and MyoFlowQ was assessed using Bland–Altman analysis. Rest and stress MBF differed significantly across the Corridor 4DM processing strategies (both P < .001). Myocardial flow reserve (MFR) differences were tracer-dependent: no overall difference was observed in global left ventricular values in the Tc-99m-methoxyisobutylisonitrile cohort ( P = .121), whereas a significant difference was observed in the Tc-99m-tetrofosmin cohort ( P = .002). Compared with Corridor 4DM using ACSC, MyoFlowQ yielded higher stress MBF and MFR values (bias, 1.19–1.31 mL·g −1 ·min −1 ; 95% limits of agreement, –0.30 to 2.68), with moderate inter-software correlation ( r = 0.44–0.59, P < .01). Post-processing methodology significantly influenced absolute MBF quantification in CZT-SPECT imaging. Within Corridor 4DM, correction strategies affected MBF estimates, and MyoFlowQ yielded higher stress MBF and MFR values than Corridor 4DM using ACSC, indicating that these post-processing approaches are not directly interchangeable.

17 August 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ACAjay Kumar Chaudhary
Ajay Kumar Chaudhary
ZPZekun Pang
Zekun Pang
FZFukai Zhao
Fukai Zhao
JNJing Ni
Jing Ni
HGHaoran Guo
Haoran Guo
JLJianming Li
Jianming Li
Background/Objectives: The effect of cardiac motion on dynamic positron emission tomography (PET) myocardial perfusion imaging (MPI) could distort the quantitative perfusion indices during acquisition, depending on direction, magnitude, and vascular territory. This study aimed to assess the impact of motion correction (MC) and its influences on quantitative perfusion indices using a comprehensive range of established statistical methods. Method: We retrospectively analyzed 171 patients’ data who underwent 13N-ammonia dynamic PET/CT-MPI. All the rebinned listmode data were transferred to the dedicated workstation for MC and quantification, yielding paired MC and non-motion correction (NMC) datasets for both phases. Frame-by-frame post-MC vectors were used to characterize motion magnitude and direction. Paired comparisons, directional analysis, association, agreement, accuracy, precision, and clinical reclassification were performed. Results: Motion occurred during both acquisition phases, but it was more frequent, more heterogeneous, and generally greater during stress, with the most notable displacement along the Y-axis. MC had a limited impact on the rest myocardial blood flow (MBF) but showed more significant effects on stress MBF, myocardial flow reserve (MFR), and non-invasive fractional flow reserve (niFFR) -like index, especially in the left anterior descending artery (LAD). Although MC and NMC values remained strongly associated for MBF and MFR, they were not fully interchangeable. The bidirectional reclassification of MFR and niFFR-like index showed that MC responded to the direction and magnitude of motion rather than a simple increase the values. Conclusions: MC exerts a structured, bidirectional, and motion-dependent influence on quantitative dynamic PET-MPI and has an impact beyond simple numerical adjustment.