Fatih Oluş

Dr. Fatih Oluş

orcid

Research Focus & Metrics

Representative Publications

View All Publications
1 February 2026 in Digital Health
Verified
Journal Article
Open access
FOFatih Oluş
Fatih Oluş
HBHüseyin Babun
Hüseyin Babun
Objective: Artificial intelligence (AI) chatbots are increasingly used by patients seeking medical information. However, the accuracy and educational quality of such tools in the context of anesthesia remain unclear. This study aimed to evaluate and compare the appropriateness of responses generated by three widely accessible AI platforms—ChatGPT, Gemini, and Copilot—regarding frequently asked questions about general anesthesia. Methods: Fifty anesthesia-related questions were developed by two anesthesiologists and categorized into four domains: General Information and Process, Safety and Risks, Pain, Comfort, and Recovery, and Preoperative Preparation. Each question was entered in English into the free, publicly available versions of ChatGPT, Gemini, and Copilot. Ten blinded anesthesiologists rated the responses using a 5-point Likert scale (1 = very inappropriate to 5 = very appropriate). Mean scores were compared using one-way ANOVA with Tukey’s post-hoc tests, and inter-rater reliability was assessed using Cronbach’s α. Results: ChatGPT achieved the highest overall mean score (4.68 ± 0.50), followed by Gemini (4.22 ± 0.63) and Copilot (3.28 ± 0.50), with significant differences among all platforms (p < 0.001). ChatGPT consistently outperformed the others across all four domains. Qualitative observations from evaluator comments suggested that ChatGPT’s concise summaries improved readability, Gemini provided more structured responses with more scholarly-style references, and Copilot was clear but often less detailed. Inter-rater reliability was high (Cronbach’s α = 0.89). Conclusion: Among free-access AI chatbots, ChatGPT provided the most accurate and comprehensive explanations regarding general anesthesia. While Gemini and Copilot offered partial value, professional oversight remains essential to ensure safe and contextually accurate patient education in preoperative care.

8 May 2026 in Frontiers in Health Services
Verified
Journal Article
Open access
PDF file
HBHüseyin Babun
Hüseyin Babun
FOFatih Oluş
Fatih Oluş
Introduction: Artificial intelligence–based chatbots are increasingly used by patients to obtain medical information before healthcare encounters. However, the reliability and safety of chatbot-generated responses remain uncertain, particularly for topics involving procedural sedation. Methods: This study evaluated the quality, safety, and confabulation risk of responses generated by ChatGPT, Gemini, and Copilot to common patient questions about procedural sedation. A set of standardized patient-oriented questions was submitted to each chatbot, and responses were independently evaluated by clinical experts using predefined criteria assessing informational quality, clinical safety, and the presence of confabulated or misleading content. Results: The results demonstrated variability in response quality across chatbots, with several answers containing incomplete information, safety omissions, or potentially misleading statements. Although many responses provided generally understandable explanations, important clinical details relevant to patient safety were inconsistently addressed. Discussion: These findings suggest that while AI chatbots may support patient education, their responses regarding procedural sedation may contain safety gaps and confabulated content that limit their reliability as standalone sources of medical information. Careful oversight and clinician-guided use of AI-generated health information may therefore be necessary to ensure safe and accurate patient communication.

14 June 2022 in Akdeniz Medical Journal
Verified
Journal Article
Closed access
FOFatih Oluş
Fatih Oluş
EGEmel Gündüz
Emel Gündüz
AAAyşe Gülbin ARICI
Ayşe Gülbin ARICI
Objective: Postoperative delirium (POD) is a common postoperative complication. This study aimed to diagnose POD early primarily in patients who underwent General Surgery. Material and Method: Data of 303 patients at the age of 18 and above who were operated by General Surgery Clinic between March 2018 and May 2018,who received general anesthesia were included in the study. Patients’ demographic data, occupation, educational status, income level, additional diseases, ASA (American Society of Anesthesia) score, previous surgeries, history of a psychiatric or neurological disease, history of alcohol, cigarette, or drug use, and memory problems were recorded. Mini Mental State Examination (MMSE) was used to identify preoperative mental levels of the patients. Diagnosis of the patient, name, duration and features of the surgery to be performed, whether the surgery was urgent or elective, drugs used, type of catheterization recorded. The diagnosis of POD in patients was evaluated with Confusion Assessment Method (CAM). Results: POD developed in 2-6% (8 patients) of the patients. Results showed that the risk of delirium decreased as the education levels of the patients increased. A significant relationship was recorded between delirium and only midazolam among anesthetic agents used. Conclusion: Diagnosing POD with CAM in an early postoperative period was advantageous. The treatment planning of the patients for POD could be done in the early period. By doing this, increase in mortality, morbidity and cost as a result of missing the diagnosis of POD was prevented. Key Words: Postoperative Delirium, General Surgery, Cognitive Disorders

4 March 2026 in Akdeniz Medical Journal
Verified
Journal Article
Closed access
FOFatih Oluş
Fatih Oluş
HBHüseyin Babun
Hüseyin Babun
ObjectiveLow and Minimal-flow Anesthesia, despite its advantages, including cost and pollution reduction and less heat/moisture loss, has limited prevalence due to concerns of complications and the need for closer monitoring. The objective of this study was to assess the benefits and risks of low- and minimal-flow anesthesia in patients undergoing oral and maxillofacial surgery.Material and MethodsConducted at Akdeniz University, 149 ASA 1-2 class patients were categorized into four Fresh Gas Flow (FGF) groups post-anesthesia induction. Data collected included vital signs, complications, operation and awakening times, and gas use.ResultsThere were no significant differences in demographics or ASA classification. However, variations in oxygen, air and sevoflurane use across the various FGF groups were identified (p

15 March 2026 in European Journal of Dental Education
Verified
Journal Article
Open access
PDF file
FOFatih Oluş
Fatih Oluş
HBHüseyin Babun
Hüseyin Babun
Introduction: The “Code Blue” system is a standardised emergency response protocol designed to ensure rapid intervention in critical medical situations, particularly cardiopulmonary arrest. Although mandatory in Türkiye since 2011, inappropriate activations still occur, often due to limited awareness among healthcare staff, including dental students. This pilot project aimed to assess dental students' knowledge and awareness regarding Code Blue and to examine whether these outcomes differ according to the level of clinical training. Materials and Methods: A cross‐sectional survey was conducted among 186 dental students at Akdeniz University, including 3rd‐year (preclinical) and 5th‐year (clinical) students. A structured 10‐item multiple‐choice questionnaire was used to evaluate participants' knowledge of Code Blue indications, activation procedures, and response expectations. Descriptive and comparative statistical analyses were performed. Results: Of the 186 students analysed, 53.2% were female and 46.8% were male. The most recognised emergency code was Code White (82.26%), followed by Code Blue (70.43%). Code Blue awareness was significantly higher among fifth‐year students (77.3%) than third‐year students (62.9%) ( p < 0.05). Fifth‐year students also demonstrated greater knowledge of Code Blue indications and were less likely to choose “don't know.” However, common misinterpretations were observed: 70.49% incorrectly identified vasovagal syncope as a Code Blue condition, and only 7.38% correctly rejected all non‐indicated scenarios. Knowledge of basic life support (BLS) content did not significantly differ between groups ( p = 0.8153). Conclusions: Code Blue knowledge and awareness were higher among students with greater clinical exposure; however, overall awareness remained limited. These findings support earlier and more structured integration of institutional emergency code training, simulation‐based reinforcement, and practical emergency preparedness training within the dental curriculum. Further multi‐center studies are recommended to enhance generalizability and guide educational interventions.

2 September 2026 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
HBHüseyin Babun
Hüseyin Babun
FOFatih Oluş
Fatih Oluş
Airway management in adults with special healthcare needs undergoing dental treatment under general anesthesia may be challenging because of limited cooper