George Darikas

Dr. George Darikas

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2025 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
GDGeorge Darikas
George Darikas
MDMatthieu Dubarry
Matthieu Dubarry
ABAnup Barai
Anup Barai
MAMark Amor-Segan
Mark Amor-Segan
DGDavid Greenwood
David Greenwood
The growing demand for high-energy-density lithium-ion batteries in portable electronics, electric vehicles, and grid storage has accelerated the introduction of silicon-graphite blended electrodes in commercially available lithium-ion cells. Despite their commercial adoption and higher energy density, the widespread deployment of silicon-graphite (Si-Gr) composites is hindered by rapid degradation phenomena which limit both their calendar and cycle life. In this work, a novel diagnostic framework that enables the quantification and separation of silicon and graphite active material losses in blended electrodes is presented, based on differential voltage and incremental capacity analysis. Expanding upon the established methods for graphite electrodes, a novel silicon-specific IC diagnostic marker is proposed for the detection of silicon active material loss. The proposed method was validated using synthetic datasets generated from the alawa mechanistic modelling toolbox, simulating a broad range of degradation mode combinations and cell architectures. The results of this work underscore the potential of diagnostic decoupling in composite anode electrodes using derivative analysis and lay the groundwork for scalable health-monitoring strategies in next-generation high-energy lithium-ion batteries.

8 January 2026 in Batteries
Verified
Journal Article
Open access
PDF file
GDGeorge Darikas
George Darikas
MKMehmet Cagin Kirca
Mehmet Cagin Kirca
NSNessa Fereshteh Saniee
Nessa Fereshteh Saniee
MRMuhammad Rashid
Muhammad Rashid
IMIhsan Mert Muhaddisoglu
Ihsan Mert Muhaddisoglu
Andrew McGordonAndrew McGordon
Andrew McGordon
This work investigated the impact of vehicle-to-grid (V2G) cycling on the service life of lithium-ion cells, using real-world V2G data from commercial electric vehicle (EV) battery chargers. Commercially available cylindrical lithium-ion cells were subjected to long-term storage and V2G cycling under varying state of charge (SOC), depth of discharge (DOD), and temperature conditions. The ageing results demonstrate that elevated temperature (40 °C) is the dominant factor accelerating degradation, particularly at a high storage SOC (>80% SOC) and increased cycle depths (30–80% SOC, 30–95% SOC). A comparison between V2G cycling and calendar ageing over a similar storage period revealed that shallow V2G cycling (30–50% SOC) leads to comparable capacity fade to storage at a high SOC (≥80% SOC). The comparative analysis indicated that 62% of a full equivalent cycle (FEC) of V2G cycling can be achieved daily, without compromising the cell’s lifetime, demonstrating the viability of V2G adoption during EV idle/charging periods, which can offer potential operational benefits in terms of cost reduction and emissions savings. Furthermore, this work introduced the concept of a V2X capability metric as a novel cell-level specification, along with a corresponding experimental evaluation method.

9 October 2022 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
GDGeorge Darikas
George Darikas
ABAnup Barai
Anup Barai
MSMuhammad Sheikh
Muhammad Sheikh
PMPeter Miller
Peter Miller
MAMark Amor-Segan
Mark Amor-Segan
DGDavid Greenwood
David Greenwood
As lithium-ion batteries are becoming the energy storage technology of choice for transport electrification, the accurate estimation and prediction of their service life remains a critical aspect for their successful adoption and integration. The established methods of lifetime estimation employ battery degradation models along with accelerated ageing test data. Although accelerated methods have been widely used in the literature over the last decade, there are still some discrepancies regarding the testing methodology and parameters. Specifically, in cycle ageing experiments, the relaxation time between cycles is chosen arbitrarily and is typically kept short to enable higher cycle throughput. Although this parameter is considered to have minimal influence on the test results1, its impact on the ageing rate and cell cycle life has not been thoroughly investigated. Furthermore, previous studies demonstrated significant capacity recovery after prolonged rest periods (≥2 days)2, however, their contribution is usually considered only at the end of the cycling ageing test3. In this work, the impact of cycling relaxation and rest periods in cycling ageing tests is systematically investigated. Commercially available cylindrical lithium-ion cells were subjected to long-term cycling at 10ºC with different discharge relaxation times. During cycling, three rest periods, i.e., 1min, 10min and 60min were investigated for the discharge relaxation steps, while the charge relaxation time was kept constant for all the cells at 1min. The cells were cycled in the manufacturer’s full voltage window with 0.3C/1C charge/discharge current respectively, and three cells were used in each test case to ensure the reproducibility of the results. At regular intervals, reference performance tests (RPT) were performed at 25°C for cell characterisation. After 6 months of ageing, a rest period of 2 weeks was incorporated into the ageing test, in order to investigate the influence of reversible losses in the course of accelerated cycling. During the rest period the cells were fully discharged and remained stored in open-circuit condition at 10°C. An RPT was conducted prior to the start as well as at the end of this period, before the cycling ageing regime was restarted. The relative capacity fade and resistance increase for the different relaxation times after approximately 8 months of ageing are presented in Figure 1. As illustrated, there is a clear increasing trend between cell degradation and relaxation time, i.e., cells that are rested for 60min after discharge are exhibiting the fastest rate of capacity fade and resistance increase. This result is counter-intuitive, since the longer the relaxation period the less cycles are performed between successive RPTs. Furthermore, the rest period is spent at low SOC, minimising the calendar ageing contributions, which are already expected to be comparatively small, due to the sub-ambient test temperature (10ºC). This behaviour was investigated further through differential voltage analysis (DVA), which revealed that the degradation modes across the three test cases exhibited minor differences, with higher losses of active material observed for the cells cycled with 60min relaxation and higher degrees of lithium inhomogeneity observed for the cells cycled with short relaxation (1min, 10min). The intermediate rest period led to significant capacity recovery for all cells, which reached up to >10% of the apparent capacity fade measured prior to the cycling break in the short relaxation test cases. The resistance values however were not affected, remaining almost constant before and after the rest period. The reversible losses were attributed to the anode overhang, due to the very low storage SOC, and to the increase in homogeneity of lithium distribution due to the increase in the peak intensity of the DVA curves. The capacity recovered through these mechanisms was effectively utilised once the ageing cycles were restarted and the ageing rates of each test case remained consistent, indicating that the cycling break did not affect the cell ageing trajectory. The results of this work demonstrate the strong influence of relaxation time on the cycle life of lithium-ion cells, which are cycled in otherwise similar conditions. This issue, which has not been reported before, needs to be considered in the design and interpretation of accelerated ageing tests. Similarly, reversible capacity losses need to be accounted and quantified in order to avoid the underestimation of cell cycle life. M. Reichert, D. Andre, A. Rösmann, P. Janssen, H. G. Bremes, D. U. Sauer, S. Passerini, and M. Winter, Journal of Power Sources, 239 45-53 (2013). B. Epding, B. Rumberg, H. Jahnke, I. Stradtmann, and A. Kwade, Journal of Energy Storage, 22 249-256 (2019). M. Lewerenz, P. Dechent, and D. U. Sauer, Journal of Energy Storage, 21 680-690 (2019). Figure 1

22 November 2024 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
GDGeorge Darikas
George Darikas
PNPuritut Nakhanivej
Puritut Nakhanivej
ABAnup Barai
Anup Barai
MLMelanie J Loveridge
Melanie J Loveridge
PMPeter Miller
Peter Miller
DGDavid Greenwood
David Greenwood
The conventional approaches of estimating the lifecycle of lithium-ion batteries utilize battery ageing models combined with data from accelerated ageing tests. Despite the prevalent use of these accelerated techniques in battery research over the years, there still exists a lack of consistency in the testing parameters and methodology. Particularly in cycle ageing tests, the rest period between cycles is typically selected without a standard criterion and is generally minimised to facilitate higher cycle throughput. Although this parameter has been considered to have minimal influence on the test results1, a recent study2 has demonstrated that cycle-to-cycle relaxation may have a significant impact on the cell cycle life, even though the investigated cells were cycled in otherwise identical conditions. This work aims to expand on the findings presented in2, by investigating the underlying mechanism of this behaviour, using X-ray CT imaging, forensic and post-mortem analysis. In this study, commercially available cylindrical lithium-ion cells were subjected to prolonged cycling with different rest periods between cycles. For the relaxation time after discharge, three time constants were selected, namely 1min, 10min and 60min, while the relaxation period after charge was kept constant at 1min. The cells were cycled at 10°C between the charge/discharge voltage cut-off limits specified by the manufacturer, with 0.3C/1C current rate for charge/discharge respectively. A clear correlation between relaxation time and cell degradation was observed in the cycling results, as the cells cycled with longer rest periods exhibited higher capacity fade (Fig.1(a)). Non-invasive diagnostic analysis conducted with differential voltage (DVA) and incremental capacity (ICA) revealed increased losses of lithium inventory and active material in the longer relaxation test cases. As the main relaxation time was after discharge, when the cells were at a low SOC and in sub-ambient temperature (10°C), calendar ageing effects are expected to be negligible, which indicates the presence of a different underlying mechanism responsible for the observed degradation pattern. At the end of the cycle ageing test, X-ray computed tomography (XCT) scans were obtained for all the tested cells, and one cell per test case was selected to be dismantled for autopsy and visual inspection. The XCT images revealed severe deformations in the jelly roll of all tested cells, in the form of kinks located in the innermost layers, between the cell's hollow core and the positive current collector tab (Fig.1(b)). Furthermore, the cell structural integrity appears to deteriorate as the relaxation period increases, since more jelly roll layers appear to be affected in the 10min and 60min test cases (Fig.1(b)). Upon dismantling, significant electrode delamination was observed in the innermost electrode areas for all test cases (Fig.1(c)-(e)), which was inherently linked to the jelly roll deformation. For the cells cycled with 60min relaxation, a bright coloured passivation layer was detected in the mid to outer layers of the negative electrode (Fig.1(e)-(f)), implying the potential occurrence of lithium plating3. Furthermore, the opposing parts of the cathode electrode corresponding to the location of the passivation layer in the anode exhibited a unique wave-like deformation pattern (Fig.1(f)), which indicates that these jelly roll regions where subjected to high mechanical stresses during cycling. The autopsy results support the preliminary diagnostic conclusions, as the presence of the covering layer and the morphological changes in the electrodes can lead to loss of active lithium and active material, due to local passivation and particle cracking. Overall, this study demonstrates that longer cycle-to-cycle relaxation periods cause higher mechanical and electrochemical stresses within the tested lithium-ion cells, which can even lead to the formation of local passivation layers, affecting their electrochemical performance and structural integrity. This effect, which has not been previously reported, does not appear to be present in all cells, as a preliminary investigation conducted with three different commercial cells of similar format did not exhibit the same trend. Although the underlying mechanisms responsible for the results presented in this study needs to be investigated further, the potential influence of relaxation on the cycling behaviour of lithium-ion cells needs to be considered in the design and interpretation of accelerated ageing tests. Reichert, D. Andre, A. Rösmann, P. Janssen, H. G. Bremes, D. U. Sauer, S. Passerini, and M. Winter, Journal of Power Sources, 239 45-53 (2013). G. Darikas, A. Barai, M. Sheikh, P. Miller, M. Amor-Segan, and D. Greenwood, in "Electrochemical Society Meeting Abstracts 242", p. 2590-2590. The Electrochemical Society, Inc., 2022. A. J. Smith, Y. Fang, A. Mikheenkova, H. Ekström, P. Svens, I. Ahmed, M. J. Lacey, G. Lindbergh, I. Furó, and R. W. Lindström, Journal of Power Sources, 573 233118 (2023). Figure 1