Accessibility of diagnostic screening and treatment monitoring devices for respiratory diseases is critical in promoting healthcare and reducing sudden complications and mortality. Spirometry is the standard for diagnosing and monitoring several lung diseases. However, it lacks regional assessment capabilities necessary for detecting subtle regional changes in certain diseases. It also requires challenging breathing maneuvers difficult for elderlies, children, and diseased patients. Here, we actualized an affordable, portable, and self-administrable electrical impedance tomography (EIT) system for home-based lung function assessment and telemedicine. Through simultaneous EIT-spirometry trials on healthy subjects, we demonstrated that our device can predict spirometry indicators over a wide range and can provide regional mapping of these indicators. We further developed a close-to-effortless breathing paradigm and tested it by longitudinally monitoring a COVID-19 discharged subject and two healthy controls with results suggesting the paradigm can detect initial deterioration followed by recovery. Overall, the EIT system can be widely applicable for lung function screening and monitoring both at homes and clinics.
4 August 2017 in IEEE Transactions on Medical Imaging
Plane-wave-based ultrafast imaging has become the prevalent technique for non-conventional ultrasound imaging. The image quality, especially in terms of the suppression of artifacts, is generally compromised by reducing the number of transmissions for a higher frame rate. We hereby propose a new ultrafast imaging framework that reduces not only the side lobe artifacts but also the axial lobe artifacts using combined transmissions with a new coherence-based factor. The results from simulations, in vitro wire phantoms, the ex vivo porcine artery, and the in vivo porcine heart show that our proposed methodology greatly reduced the axial lobe artifact by 25±5 dB compared with coherent plane-wave compounding (CPWC), which was considered as the ultrafast imaging standard, and suppressed side lobe artifacts by 15 ± 5 dB compared with CPWC and coherent spherical-wave compounding. The reduction of artifacts in our proposed ultrafast imaging framework led to a better boundary delineation of soft tissues than CPWC.
26 June 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
The heart is an organ with highly dynamic complexity, including cyclic fast electrical activation, muscle kinematics, and blood dynamics. Although ultrafast cardiac imaging techniques based on pulsed-wave ultrasound (PUS) have rapidly emerged to permit mapping of heart dynamics, they suffer from limited sonographic signal-to-noise ratio (SNR) and penetration due to insufficient energy delivery and inevitable attenuation through the chest wall. We hereby propose ultrafast cascaded-wave ultrasound (uCUS) imaging to depict heart dynamics in higher SNR and larger penetration than conventional ultrafast PUS. To solve the known tradeoff between the length of transmitted ultrasound signals and spatial resolution while achieving ultrafast frame rates (>1000 Hz), we develop a cascaded synthetic aperture (CaSA) imaging method. In CaSA, an array probe is divided into subapertures; each subaperture transmits a train of diverging waves. These diverging waves are weighted in both the aperture (i.e., spatial) and range (i.e., temporal) directions with a coding matrix containing only +1 and -1 polarity coefficients. A corresponding spatiotemporal decoding matrix is designed to recover backscattered signals. The decoded signals are thereafter beamformed and coherently compounded to obtain one high-SNR beamformed image frame. For CaSA with $M$ subapertures and $N$ cascaded diverging waves, sonographic SNR is increased by $10\times $ log$_{10}\,\,(N \times M)$ (dB) compared with conventional synthetic aperture (SA) imaging. The proposed uCUS with CaSA was evaluated with conventional SA and Hadamard-encoded SA (H-SA) methods in a calibration phantom for B-mode image quality and an $in\,\, vivo$ human heart in a transthoracic setting for the quality assessment of anatomical, myocardial motion, and chamber blood power Doppler images. Our results demonstrated that the proposed uCUS with CaSA (4 subapertures, 32 cascaded waves) improved SNR (+20.46 dB versus SA, +14.83 dB versus H-SA) and contrast ratio (+8.44 dB versus SA, +7.81 dB versus H-SA) with comparable spatial resolutions to and at the same frame rates as benchmarks.
The geometry and stiffness of a vessel are pertinent to blood dynamics and vessel wall mechanical behavior and may alter in diseased conditions. Ultrasound-based ultrafast Doppler (uDoppler) imaging and shear wave imaging (SWI) techniques have been extensively exploited for the assessment of vascular hemodynamics and mechanics. Their performance is conventionally validated on vessel-mimicking phantoms (VMPs) prior to their clinical use. Compared with commercial ones, customized VMPs are favored for research use because of their wider range of material properties, more complex lumen geometries, or wall structures. Fused deposition modeling (FDM) 3D printing technique with plastic filaments is a promising method for making VMPs with a complex vessel lumen. However, it may require a toxic solvent or a long dissolution time currently. In this paper, we present a safe, efficient and geometrically flexible method where FDM 3D printing with a water-soluble polyvinyl alcohol (PVA) filament is exploited to fabricate a walled three-branch VMP (VMP-I). As a key step in fabrication, to avoid dissolution of the PVA-printed vessel core by the solution of the tissue-mimicking material, paraffin wax was used for isolation. Paraffin wax is easy to coat (i.e. without any special equipment), of satisfactory thickness (∼0.1 mm), chemically stable, and easy to remove after fabrication, thus making the proposed method practicable for ultrasound imaging studies. VMP-I was examined by B-mode imaging and power Doppler imaging (PDI) to verify complete dissolution of PVA-printed vessel core in its lumen, confirming good fabrication quality. The flow velocities in VMP-I were estimated by uDoppler imaging with a −0.8% difference, and the shear wave propagation speeds for the same phantom were estimated by SWI with a −6.03% difference when compared with fluid-structure interaction (FSI) simulation results. A wall-less VMP of a scaled and simplified coronary arterial network (VMP-II) was additionally fabricated and examined to test the capability of the proposed method for a complex lumen geometry. The proposed fabrication method for customized VMPs is foreseen to facilitate the development of ultrasound imaging techniques for blood vessels.
Objective. A phased or a curvilinear array produces ultrasound (US) images with a sector field of view, which inherently exhibits spatially-varying image resolution with inferior quality in the far zone and towards the two sides azimuthally. Sector US images with improved spatial resolutions are favorable for accurate quantitative analysis of large and dynamic organs, such as the heart. Therefore, this study aims to translate US images with spatially-varying resolution to ones with less spatially-varying resolution. CycleGAN has been a prominent choice for unpaired medical image translation; however, it neither guarantees structural consistency nor preserves backscattering patterns between input and generated images for unpaired US images. Approach. To circumvent this limitation, we propose a constrained CycleGAN (CCycleGAN), which directly performs US image generation with unpaired images acquired by different ultrasound array probes. In addition to conventional adversarial and cycle-consistency losses of CycleGAN, CCycleGAN introduces an identical loss and a correlation coefficient loss based on intrinsic US backscattered signal properties to constrain structural consistency and backscattering patterns, respectively. Instead of post-processed B-mode images, CCycleGAN uses envelope data directly obtained from beamformed radio-frequency signals without any other nonlinear postprocessing. Main results . In vitro phantom results demonstrate that CCycleGAN successfully generates images with improved spatial resolution as well as higher peak signal-to-noise ratio and structural similarity compared with benchmarks. Significance . CCycleGAN-generated US images of the in vivo human beating heart further facilitate higher quality heart wall motion estimation than benchmarks-generated ones, particularly in deep regions. The codes are available at https://github.com/xfsun99/CCycleGAN-TF2