Aneta Hałka-Grysińska

Dr. Aneta Hałka-Grysińska


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Journal of Chromatography A
Verified
Journal Article
Closed access
AHAneta Hałka-Grysińska
Aneta Hałka-Grysińska
KSKamila Skop
Kamila Skop
AKAnna Klimek-Turek
Anna Klimek-Turek
MGMarta Gorzkowska
Marta Gorzkowska
TDTadeusz H. Dzido
Tadeusz H. Dzido

5 March 2013 in Chromatographia
Verified
Journal Article
Open access
PDF file
AHAneta Hałka-Grysińska
Aneta Hałka-Grysińska
PŚPiotr Ślązak
Piotr Ślązak
ATAndrzej Torbicz
Andrzej Torbicz
MSMietek Mieczysław Sajewicz
Mietek Mieczysław Sajewicz
TDTadeusz H. Dzido
Tadeusz H. Dzido
Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liquid chromatography, especially thin layer chromatography (planar chromatography, TLC), are features of this technique. Constructional methodological challenges to PPEC are obstacles to its development and application in laboratory practice. In this article, an attempt to overcome the challenges related to device construction and sample application/injection is described. The introduced device enables both prewetting of the adsorbent layer and electrochromatogram development with a single PPEC device. It also enables simultaneous application/injection of six samples on a chromatographic plate in a stream of the mobile phase (on-line application/injection). In addition, the PPEC chamber was equipped with a thermostat. The device is characterized by an impressive throughput in comparison to the other planar technique, TLC/HPTLC. Although the developed device still needs improvement, it is, in our opinion, a considerable step toward possible automation of this planar separation technique.

1 January 2020 in Journal of Chromatography A
Verified
Journal Article
Closed access
AHAneta Hałka-Grysińska
Aneta Hałka-Grysińska
ACAnna Cyrta
Anna Cyrta
TDTadeusz Henryk Dzido
Tadeusz Henryk Dzido

16 July 2013 in Journal of Liquid Chromatography & Related Technologies
Verified
Journal Article
Closed access
AHAneta Hałka-Grysińska
Aneta Hałka-Grysińska
PPPaweł W. Płocharz
Paweł W. Płocharz
RSRobert Szczap
Robert Szczap
TDTadeusz H. Dzido
Tadeusz H. Dzido
Pressurized planar electrochromatography (PPEC) is a separating technique, in which an electric field is applied to force movement of the mobile phase through a porous media (electroosmotic effect). High separation efficiency, fast separation, and changes in separation selectivity in comparison to liquid chromatography, especially to thin-layer chromatography (planar chromatography, TLC) are features of this technique. Our group has recently introduced the prototype device, which enables simultaneous on-line injection of six samples on chromatographic plate in a stream of the mobile phase. In this paper influence of some operating variables of on-line injection mode on efficiency of PPEC separation system is shown and discussed.

1 June 2014 in Chromatographia
Verified
Journal Article
Open access
PDF file
AHAneta Hałka-Grysińska
Aneta Hałka-Grysińska
PPPaweł W. Płocharz
Paweł W. Płocharz
ATAndrzej Torbicz
Andrzej Torbicz
Ewa SkwarekEwa Skwarek
Ewa Skwarek
WJWładysław Janusz
Władysław Janusz
TDTadeusz H. Dzido
Tadeusz H. Dzido
The aim of this work was to find a relationship between electroosmotic flow (EOF) velocity of the mobile phase in pressurized planar electrochromatography (PPEC) and physicochemical properties like zeta potential, dielectric constant, and viscosity of the mobile phase as well as its composition. The study included different types of organic modifiers (acetonitrile, methanol, ethanol, acetone, formamide, N-methylformamide and N,N-dimethylformamide) in the full concentration range. In all experiments, chromatographic glass plates HPTLC RP-18 W from Merck (Darmstadt) were used as a stationary phase. During the study we found that there is no linear correlation between EOF velocity of the mobile phase and single variables such as zeta potential or dielectric constant or viscosity. However, there is quite strong linear correlation between EOF velocity of the mobile phase and variable obtained by multiplying zeta potential of the stationary phase–mobile phase interface, by dielectric constant of the mobile phase solution and dividing by viscosity of the mobile phase. Therefore, it could be concluded that the PPEC system fulfilled the Helmholtz–Smoluchowski equation.

1 July 2021 in Journal of Chromatography A
Verified
Journal Article
Closed access
AHAneta Hałka-Grysińska
Aneta Hałka-Grysińska
ASAdrian Szczyrba
Adrian Szczyrba
TDTadeusz H. Dzido
Tadeusz H. Dzido
RKRoman Kaliszan
Roman Kaliszan