Zhiqiang Yan

Mr. Zhiqiang Yan

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
ZYZhiqiang Yan
Zhiqiang Yan
HZHaoqing Zhang
Haoqing Zhang
XWXinlu Wang
Xinlu Wang
MGMartina Gaňová
Martina Gaňová
TLTomáš Lednický
Tomáš Lednický
PNPavel Neuzil
Pavel Neuzil
We developed an image-to-answer algorithm available for chip-based dPCR systems with single fluorescence image capture and known image-related error removal. It automatically corrects the chip structure damage and non-uniformity of light intensity.

12 January 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
MGMartina Gaňová
Martina Gaňová
XWXinlu Wang
Xinlu Wang
ZYZhiqiang Yan
Zhiqiang Yan
HZHaoqing Zhang
Haoqing Zhang
TLTomáš Lednický
Tomáš Lednický
PNPavel Neuzil
Pavel Neuzil
A microfluidic-based digital polymerase chain reaction (dPCR) chip requires precise temperature control as well as uniform temperature distribution to ensure PCR efficiency. However, measuring local temperature and its distribution over thousands of μL/nL-volume samples with minimum disturbance is challenging. Here, we present a method of non-contact localized temperature measurement for determination of the non-uniformity of temperature distribution over a dPCR chip. We filled the dPCR chip with a PCR solution containing amplified DNA fragments with a known melting temperature (TM). We then captured fluorescent images of the chip when it was heated from 70 to 99 °C, plotted the fluorescence intensity of each partition as a function of temperature, and calculated measured TM values from each partition. Finally, we created a 3-D map of the dPCR chip with the measured TM as the parameter. Even when the actual TM of the PCR solution was constant, the measured TM value varied between locations due to temperature non-uniformity in the dPCR chip. The method described here thereby characterized the distribution of temperature non-uniformity using a PCR solution with known TM as a temperature sensor. Among the non-contact temperature measurement methods, the proposed TM-based method can determine the temperature distribution within the chip, instead of only at the chip surface. The method also does not suffer from the undesirable photobleaching effect of fluorescein-based temperature measurement method. Temperature determination over the dPCR chip based on TM allowed us to calibrate the temperature sensor and improve the dPCR configuration and precision. This method is also suitable for determining the temperature uniformity of other microarray systems where there is no physical access to the system and thus direct temperature measurement is not possible.

15 April 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XLXiaocheng Liu
Xiaocheng Liu
XWXinlu Wang
Xinlu Wang
HZHaoqing Zhang
Haoqing Zhang
ZYZhiqiang Yan
Zhiqiang Yan
MGMartina Gaňová
Martina Gaňová
PNPavel Neuzil
Pavel Neuzil

6 November 2025 in RSC Advances
Verified
Journal Article
Open access
PDF file
ZYZhiqiang Yan
Zhiqiang Yan
YRYulin Ren
Yulin Ren
JJJaromír Jarušek
Jaromír Jarušek
JBJan Brodský
Jan Brodský
IGImrich Gablech
Imrich Gablech
PNPavel Neuzil
Pavel Neuzil
Fluorescence imaging underpins digital PCR (dPCR), microarrays, and microfluidic biosensors, yet precise image integration remains a technical bottleneck when the sample area exceeds the microscope field of view.

7 August 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
HZHaoqing Zhang
Haoqing Zhang
SLSoňa Laššáková
Soňa Laššáková
ZYZhiqiang Yan
Zhiqiang Yan
XWXinlu Wang
Xinlu Wang
PŠPavel Šenkyřík
Pavel Šenkyřík
PNPavel Neuzil
Pavel Neuzil

20 June 2026 in Ocean Engineering
Verified
Journal Article
Closed access
LXLiwei Xuan
Liwei Xuan
MLMingyong Liu
Mingyong Liu
GHGuoyuan He
Guoyuan He
ZYZhiqiang Yan
Zhiqiang Yan