CHIRANJIB KOLEY

CHIRANJIB KOLEY

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2022 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
SKSubashis Karmakar
Subashis Karmakar
SKSupreeti Kamilya
Supreeti Kamilya
PDPrasenjit Dey
Prasenjit Dey
PGParag K. Guhathakurta
Parag K. Guhathakurta
MDMamata Dalui
Mamata Dalui
ABAnupam Basu
Anupam Basu

12 September 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BSBadal Sarkar
Badal Sarkar
DMDipak Kumar Mishra
Dipak Kumar Mishra
CKCHIRANJIB KOLEY
CHIRANJIB KOLEY
NRNirmal Kumar Roy
Nirmal Kumar Roy
PBPalas Biswas
Palas Biswas
The detection of partial discharges (PDs), inside high-voltage (HV) power apparatus, such as transformers, busing, switchgear, and so on, is important as it provides most early indication of failure. This paper presents a novel fiber Bragg grating (FBG)-based intensity-modulated fiber-optic PD sensor. The proposed sensor has been designed to be placed inside the HV equipment, and can detect high-frequency acoustic wave, as emitted due to the occurrence of PDs. For sensing, two pairs of FBGs with partial overlapping spectrum have been placed in full-bridge combination, on the opposite sides of a suitable designed elastic element of a high dielectric constant material. The proposed full-bridge combination modulates the intensity of the reflected light due to vibration of the elastic element. Thus, the proposed sensor does not require either a fiber Bragg grating analyzer or a narrowband tunable laser source, which is conventionally used in FBG-based sensors. Moreover, the proposed sensor also inherently eliminates the error due to large variation in the temperature of the HV equipment, operating at different parts of the world. The fundamental design equations and experimental results are presented in this paper. From this paper, it has been found that the proposed sensor has reasonable good dynamic responses, signal-to-noise ratio, and sensitivity.

22 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SMSukanya Mitra
Sukanya Mitra
CKCHIRANJIB KOLEY
CHIRANJIB KOLEY
Faults in bearings interrupt the operation of three-phase induction motors (IMs) and disturb factory production. Vibration signal analysis, feature extraction, and incorporation of artificial intelligence can enhance the ability of fault detection in bearings. However, implementing these techniques is challenging in industries due to harsh environmental conditions and massive computational power. Prioritizing the issue, this article presents a fusion method considering the time-frequency contents of vibration signals via the super-resolution property of wavelets and a two-dimensional convolutional neural network (2-D-CNN). First, a laboratory-based real-time process is considered with Variable Frequency Drive (VFD) driven IM which is also exposed to environmental vibration. In the present work, a piezoelectric sensor is used to collect the vibration of IM during operation. Then the collected time-series signals are stored in a computer through a Data Acquisition System (DAS). Further, signals are segmented in small windows to extract respective feature images using Continuous Wavelet Transform (CWT), Stockwell Transform (ST), and Adaptive Superlet Transform (ASLT). Thereafter, the image resolution is optimally resized and fed to a 2-D-CNN model for multi-label classification of the bearings. It is observed that ASLT-2-D-CNN with 32×32×3 resolution outperforms the other two fusion methods as it reports high accuracy and reduces runtime (training and testing) along with memory usage. The robustness of ASLT-2-D-CNN is also validated with two open-source bearing datasets. Thus, the result indicates that the proposed method for bearing fault detection can be deployed in the field to make IMs safe which reduces the maintenance cost of the industry.

23 December 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SDSourav Dhara
Sourav Dhara
CKCHIRANJIB KOLEY
CHIRANJIB KOLEY
SCSivaji Chakravorti
Sivaji Chakravorti
A Partial Discharge (PD) monitoring system for Air Insulated Substations (AIS) has been developed for monitoring of partial discharge activities of various insulators and insulating media that are distributed over an electrical substation. The proposed system utilizes four UHF (ultra-high frequency) sensors, which are to be placed around the area of interest so that any impulsive UHF signal originated from PD activity can be captured and subsequently processed for detection and localization of multiple PD sources. To improve the localization accuracy and to improve the detection specificity, i.e., to eliminate false impulsive UHF signals originated from other sources, two novel approaches, namely, Nearest-Neighbour and Probabilistic Grid-Search are proposed, which utilize the physical layout of the AIS to identify most probable PD source locations. The proposed algorithm can accurately find the PD source locations even in the presence of high time-delay-of-arrival (TDOA) estimation error by making necessary corrections in the PD source location estimation. The proposed algorithm has been field trialed in a medium-size distribution substation. A detailed comparative study with the conventionally used PD source localization approach in different extreme situations has been performed with the help of simulation, laboratory as well as field-based testing. The obtained results are worthwhile for supporting the widespread implementation of the proposed method.

6 August 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ABAnitha Bhukya
Anitha Bhukya
CKCHIRANJIB KOLEY
CHIRANJIB KOLEY
Partial discharge (PD) monitoring of electrical substations could provide early warning of insulation failures. Among the various technologies, Radio Frequency (RF) based PD monitoring system could be a promising solution. The RF-based monitoring system detects PD sources in the substation and can also localise the PD sources. The time difference of arrival (TDOA) based PD localisation system primarily require arrival time (AT) of the impulsive RF signal. Though many localisation algorithms have been proposed in the recent past to overcome the TDOA estimation errors, less attention has been given to the accurate estimation of RF PD signal arrival time. This paper presents the AT's automatic labelling in the RF PD signal using Bi-Long Short-Term Memory (Bi-LSTM) network applied on the continuous wavelet transformed (CWT) signal. Further, it also shows PD signal augmentation to overcome the problem of limited representative training data set. The behavior of the radiated RF signals is influenced by many factors and has almost stochastic characteristics. The proposed system has been validated with laboratory-based experimental signals and the data set obtained from different electrical substations. The results show that the improved performance is obtained from the combination of a multilayer Bi-LSTM model and an augmented training set.

23 December 2023 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
SMSukanya Mitra
Sukanya Mitra
CKCHIRANJIB KOLEY
CHIRANJIB KOLEY