Frederic Van Assche

Mr. Frederic Van Assche

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FAFrederic Van Assche
Frederic Van Assche
SVSander Vanheule
Sander Vanheule
LHLuc Van Hoorebeke
Luc Van Hoorebeke
Matthieu BooneMatthieu Boone
Matthieu Boone
Photon counting X-ray imagers have found their way into the mainstream scientific community in recent years, and have become important components in many scientific setups. These camera systems are in active development, with output data rates increasing significantly with every new generation of devices. A different class of PCD (Photon Counting Detector) devices has become generally available, where camera data output is no longer a matrix of photon counts but instead direct measurements of the deposited charge per pixel in every frame, which requires significant off-camera processing. This type of PCD, called a hyperspectral X-ray camera due to its fully spectroscopic output, yet again increases the demands put on the acquisition and processing backend. Not only are bandwidth requirements increased, but the need to do extensive data processing is also introduced with these hyperspectral PCD devices. To cope with these new developments the Spectral X-ray Imaging Data Acquisition framework (SpeXIDAQ) has been developed. All aspects of the imaging pipeline are handled by the SpeXIDAQ framework: from detector control and frame grabbing, to processing, storage and live visualisation during experiments.

11 April 2022 in Advanced Science
Verified
Journal Article
Open access
Chun HuangChun Huang
Chun Huang
MWMatthew D. Wilson
Matthew D. Wilson
KSKosuke Suzuki
Kosuke Suzuki
ELEnzo Liotti
Enzo Liotti
TCThomas Connolley
Thomas Connolley
CLChu Lun Alex Leung
Chu Lun Alex Leung
The performance of Li+ ion batteries (LIBs) is hindered by steep Li+ ion concentration gradients in the electrodes. Although thick electrodes (≥300 µm) have the potential for reducing the proportion of inactive components inside LIBs and increasing battery energy density, the Li+ ion concentration gradient problem is exacerbated. Most understanding of Li+ ion diffusion in the electrodes is based on computational modeling because of the low atomic number (Z) of Li. There are few experimental methods to visualize Li+ ion concentration distribution of the electrode within a battery of typical configurations, for example, coin cells with stainless steel casing. Here, for the first time, an interrupted in situ correlative imaging technique is developed, combining novel, full‐field X‐ray Compton scattering imaging with X‐ray computed tomography that allows 3D pixel‐by‐pixel mapping of both Li+ stoichiometry and electrode microstructure of a LiNi0.8Mn0.1Co0.1O2 cathode to correlate the chemical and physical properties of the electrode inside a working coin cell battery. An electrode microstructure containing vertically oriented pore arrays and a density gradient is fabricated. It is shown how the designed electrode microstructure improves Li+ ion diffusivity, homogenizes Li+ ion concentration through the ultra‐thick electrode (1 mm), and improves utilization of electrode active materials.

1 January 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
Matthieu BooneMatthieu Boone
Matthieu Boone
FAFrederic Van Assche
Frederic Van Assche
SVSander Vanheule
Sander Vanheule
SCSilvia Cipiccia
Silvia Cipiccia
HWHongchang Wang
Hongchang Wang
LHLuc Van Hoorebeke
Luc Van Hoorebeke
Multilayer monochromator devices are commonly used at (imaging) beamlines of synchrotron facilities to shape the X-ray beam to relatively small bandwidth and high intensity. However, stripe artefacts are often observed and can deteriorate the image quality. Although the intensity distribution of these artefacts has been described in the literature, their spectral distribution is currently unknown. To assess the spatio-spectral properties of the monochromated X-ray beam, the direct beam has been measured for the first time using a hyperspectral X-ray detector. The results show a large number of spectral features with different spatial distributions for a [Ru, B4C] strip monochromator, associated primarily with the higher-order harmonics of the undulator and monochromator. It is found that their relative contributions are sufficiently low to avoid an influence on the imaging data. The [V, B4C] strip suppresses these high-order harmonics even more than the former, yet at the cost of reduced efficiency.

20 August 2018 in Materials
Verified
Journal Article
Open access
PDF file
ASAbhishek Shastry
Abhishek Shastry
PMPaolo Palacio Mancheno
Paolo Palacio Mancheno
KBKarl Braeckman
Karl Braeckman
SVSander Vanheule
Sander Vanheule
IJIvan Josipovic
Ivan Josipovic
Matthieu BooneMatthieu Boone
Matthieu Boone
Recent advances in high resolution X-ray tomography (μCT) technology have enabled in-situ dynamic μCT imaging (4D-μCT) of time-dependent processes inside 3D structures, non-destructively and non-invasively. This paper illustrates the application of 4D-μCT for visualizing the removal of fatty liquids from kitchen sponges made of polyurethane after rinsing (absorption), squeezing (desorption) and cleaning (adding detergents). For the first time, time-dependent imaging of this type of system was established with sufficiently large contrast gradient between water (with/without detergent) and olive oil (model fat) by the application of suitable fat-sensitive X-ray contrast agents. Thus, contrasted olive oil filled sponges were rinsed and squeezed in a unique laboratory loading device with a fluid flow channel designed to fit inside a rotating gantry-based X-ray μCT system. Results suggest the use of brominated vegetable oil as a preferred contrast agent over magnetite powder for enhancing the attenuation coefficient of olive oil in a multi fluid filled kitchen sponge. The contrast agent (brominated vegetable oil) and olive oil were mixed and subsequently added on to the sponge. There was no disintegration seen in the mixture of contrast agent and olive oil during the cleaning process by detergents. The application of contrast agents also helped in accurately tracking the movement and volume changes of soils in compressed open cell structures. With the in house-built cleaning device, it was quantified that almost 99% of cleaning was possible for contrasted olive oil (brominated vegetable oil with olive oil) dispersed in the sponge. This novel approach allowed for realistic mimicking of the cleaning process and provided closer evaluation of the effectiveness of cleaning by detergents to minimize bacterial growth.

1 August 2018 in Hearing Research
Verified
Journal Article
Closed access
RCRaf Claes
Raf Claes
PMPieter G.G. Muyshondt
Pieter G.G. Muyshondt
FAFrederic Van Assche
Frederic Van Assche
LHLuc Van Hoorebeke
Luc Van Hoorebeke
PAPeter Aerts
Peter Aerts
JDJoris Dirckx
Joris Dirckx

1 November 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
FAFrederic Van Assche
Frederic Van Assche
SVS. Vanheule
S. Vanheule
SCS. Cipiccia
S. Cipiccia
LVL. Vincze
L. Vincze
LHL. Van Hoorebeke
L. Van Hoorebeke
MBM.N. Boone
M.N. Boone
Hyperspectral X-ray detectors, which provide the full energy spectrum detected by each individual pixel, have become available for use in lab-based facilities. The addition of spectral information currently comes at the cost of low overall acceptable flux rates, and can introduce countrate nonlinearity at higher energies. Neither of these drawbacks are desirable for transmission imaging and tomography. In this paper a new data processing software chain is presented for the SLcam, a pnCCD-based hyperspectral camera prototype, allowing for more control over the conversion from raw frames to hyperspectral images. Complementary to the processing software, a set of live data visualisations was developed to aid in monitoring ongoing experiments and to allow for preliminary data processing on-the-fly. The combination of these software elements forms the first step towards general applicability of hyperspectral imaging at laboratory tomography setups.