Bing Zhang

Dr. Bing Zhang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PSPeng Su
Peng Su
XZXiaoyi zhu
Xiaoyi zhu
YCYanjiang Chen
Yanjiang Chen
BXBing Xue
Bing Xue
BZBing Zhang
Bing Zhang
To study the influence of near-fault and far-field (FF) ground motions on a curved girder bridge, a 1:10 scale curved bridge shaking table test model was constructed. Three types of ground motions, namely, near-fault pulse (NP), near-fault non-pulse (NN), and FF ground motions, were selected and employed in the test model. The test results indicated that the seismic response of the curved bridge in the excitation of NP ground motion is significantly higher than that in the excitation of NN and FF ground motions, and is destructive to the curved bridge. The displacement of the curved bridge has spatial characteristics in the excitation of NP ground motions. The rotation generated by the curved bridge is easy to cause bearing shedding or girder falling at the low pier. The amplification of pier height increases the displacement response at the high pier.

28 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
GGGao Gao
Gao Gao
YZYi Xiao Zhu
Yi Xiao Zhu
XZXiao-feng Zhang
Xiao-feng Zhang
BXBing Xue
Bing Xue
JXJilou Xi
Jilou Xi
XWXu Wu
Xu Wu
In the field of space gravitational wave detection, high-precision temperature measurement with a resolution at the micro-Kelvin level in the milli-Hertz frequency range is required to mitigate the interference caused by temperature fluctuations around the core components. This is a very challenging task due to resistance thermal noise and the inherent 1/f noise of electronic components. To overcome this problem, this paper proposes a low-noise, high-resolution temperature measurement method based on an inductive voltage divider and an alternating-current (AC) bridge. The proposed method has the following three characteristics: (1) it employs an AC excitation signal to drive the temperature measuring bridge to overcome the influence of 1/f noise in electronic components; (2) it uses as few resistance components as possible in the AC bridge and signal detection circuit to reduce the impact of resistance thermal noise on the measurement results; (3) it adopts a frequency-domain data processing algorithm based on discrete Fourier transform to improve the accuracy of the temperature measuring result. Using this method, a circuit board is designed and tested. The results show that the noise floor level of the designed temperature measurement circuit is below 7×10−6 K/Hz in a frequency range of 0.005~1 Hz. This demonstrates that our proposed method is able to detect extremely weak temperature change signals and meets the temperature measurement requirements of space gravitational wave detection.