Bryan James Black

Bryan James Black


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2017 in The Journal of Neuroscience
Verified
Journal Article
Closed access
PDF file
JMJamie K. Moy
Jamie K. Moy
AKArkady Khoutorsky
Arkady Khoutorsky
MAMarina N. Asiedu
Marina N. Asiedu
BBBryan James Black
Bryan James Black
JKJasper L. Kuhn
Jasper L. Kuhn
TPTheodore J. Price
Theodore J. Price
Injury-induced sensitization of nociceptors contributes to pain states and the development of chronic pain. Inhibiting activity-dependent mRNA translation through mechanistic target of rapamycin and mitogen-activated protein kinase (MAPK) pathways blocks the development of nociceptor sensitization. These pathways convergently signal to the eukaryotic translation initiation factor (eIF) 4F complex to regulate the sensitization of nociceptors, but the details of this process are ill defined. Here we investigated the hypothesis that phosphorylation of the 5′ cap-binding protein eIF4E by its specific kinase MAPK interacting kinases (MNKs) 1/2 is a key factor in nociceptor sensitization and the development of chronic pain. Phosphorylation of ser209 on eIF4E regulates the translation of a subset of mRNAs. We show that pronociceptive and inflammatory factors, such as nerve growth factor (NGF), interleukin-6 (IL-6), and carrageenan, produce decreased mechanical and thermal hypersensitivity, decreased affective pain behaviors, and strongly reduced hyperalgesic priming in mice lacking eIF4E phosphorylation (eIF4ES209A). Tests were done in both sexes, and no sex differences were found. Moreover, in patch-clamp electrophysiology and Ca2+ imaging experiments on dorsal root ganglion neurons, NGF- and IL-6-induced increases in excitability were attenuated in neurons from eIF4ES209A mice. These effects were recapitulated in Mnk1/2−/− mice and with the MNK1/2 inhibitor cercosporamide. We also find that cold hypersensitivity induced by peripheral nerve injury is reduced in eIF4ES209A and Mnk1/2−/− mice and following cercosporamide treatment. Our findings demonstrate that the MNK1/2–eIF4E signaling axis is an important contributing factor to mechanisms of nociceptor plasticity and the development of chronic pain. SIGNIFICANCE STATEMENT Chronic pain is a debilitating disease affecting approximately one in three Americans. Chronic pain is thought to be driven by changes in the excitability of peripheral nociceptive neurons, but the precise mechanisms controlling these changes are not elucidated. Emerging evidence demonstrates that mRNA translation regulation pathways are key factors in changes in nociceptor excitability. Our work demonstrates that a single phosphorylation site on the 5′ cap-binding protein eIF4E is a critical mechanism for changes in nociceptor excitability that drive the development of chronic pain. We reveal a new mechanistic target for the development of a chronic pain state and propose that targeting the upstream kinase, MAPK interacting kinase 1/2, could be used as a therapeutic approach for chronic pain.

10 July 2019 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
AJAlexandra Joshi-Imre
Alexandra Joshi-Imre
BBBryan James Black
Bryan James Black
JAJustin Abbott
Justin Abbott
AKAswini Kanneganti
Aswini Kanneganti
RRRashed Rihani
Rashed Rihani
SCStuart F Cogan
Stuart F Cogan
Objective . Clinical applications of implantable microelectrode arrays are currently limited by device failure due to, in part, mechanical and electrochemical failure modes. To overcome this challenge, there is significant research interest in the exploration of novel array architectures and encapsulation materials. Amorphous silicon carbide (a-SiC) is biocompatible and corrosion resistant, and has recently been employed as a coating on biomedical devices including planar microelectrode arrays. However, to date, the three-dimensional Utah electrode array (UEA) is the only array architecture which has been approved by the food and drug administration (FDA) for long-term human trials. Approach . Here, we demonstrate, for the first time, that UEAs can be fabricated with a-SiC encapsulation and sputtered iridium oxide film (SIROF) electrode coatings, and that such arrays are capable of single-unit recordings over a 30 week implantation period in rat motor cortex. Over the same period, we carried out electrochemical measurements, including voltage transients, cyclic voltammetry, and electrochemical impedance spectroscopy (EIS), to evaluate potential failure modes. Furthermore, we evaluated chronic foreign body response via fluorescence immunohistochemistry following device explantation. Main results . During the indwelling period, we observed a reduction in active electrode yield percentage from 94.6 ± 5.4 (week 1) to 16.4 ± 11.5% (week 30). While the average active electrode yield showed a steady reduction, it is noteworthy that 3 out of 8 UEAs recorded greater than 60% active electrode yield at all times through 24 weeks and 1 out of 8 UEAs recorded greater than 60% active electrode yield at all times through the whole implantation period. Significance . In total, these findings further suggest that a-SiC may serve as a mechanically and electrochemically stable device encapsulation alternative to polymeric coatings such as Parylene-C.

1 June 2020 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
RARahul Atmaramani
Rahul Atmaramani
JPJoseph J. Pancrazio
Joseph J. Pancrazio
BBBryan James Black
Bryan James Black

1 February 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
BBBryan James Black
Bryan James Black
RARahul Atmaramani
Rahul Atmaramani
SPSarah Plagens
Sarah Plagens
ZCZachary T. Campbell
Zachary T. Campbell
GDGregory Dussor
Gregory Dussor
Joseph  PancrazioJoseph Pancrazio
Joseph Pancrazio

25 March 2019 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
AKAnil Koklu
Anil Koklu
RARahul Atmaramani
Rahul Atmaramani
AHAudrey Hammack
Audrey Hammack
ABAli Beskok
Ali Beskok
JPJoseph J Pancrazio
Joseph J Pancrazio
BBBryan James Black
Bryan James Black
An ideal microelectrode array (MEA) design should include materials and structures which exhibit biocompatibility, low electrode polarization, low impedance/noise, and structural durability. Here, the fabrication of MEAs with indium tin oxide (ITO) electrodes deposited with self-similar gold nanostructures (GNS) is described. We show that fern leaf fractal-like GNS deposited on ITO electrodes are conducive for neural cell attachment and viability while reducing the interfacial impedance more than two orders of magnitude at low frequencies (100–1000 Hz) versus bare ITO. GNS MEAs, with low interfacial impedance, allowed the detection of extracellular action potentials with excellent signal-to-noise ratios (SNR, 20.26 ± 2.14). Additionally, the modified electrodes demonstrated electrochemical and mechanical stability over 29 d in vitro .

1 October 2019 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
JUJoshua Usoro
Joshua Usoro
ESEllen Shih
Ellen Shih
BBBryan James Black
Bryan James Black
RRRashed T Rihani
Rashed T Rihani
JAJustin Abbott
Justin Abbott
SCStuart F Cogan
Stuart F Cogan
Utah electrode arrays (UEAs) enable the recording of neuronal activity that informs the understanding of cortical connectivity and function, and can be used to control brain-machine/computer interfaces. However, UEAs have shown a reduced ability to resolve single unit activity (SUA) over time, prompting efforts such as the use of alternative insulation materials and reliance of local field potentials (LFPs) to improve device robustness and stability of neuroprosthetic control signals, respectively. The effect of different electrode insulation materials on LFP stability, particularly with UEAs, has not been extensively investigated, especially in rats, which provide a well-studied model for behavior and motor cortex injury. Here, we report the chronic stability of LFPs from both Parylene-C- and amorphous silicon carbide-encapsulated UEAs implanted in the rat motor cortex. We observed a decrease in bandpower in anesthetized rats for both array types that converged to the same magnitude at 30 weeks. In awake, freely-behaving rats however, there was relatively stable bandpower in both array types across individual frequency bands. In total, our results are consistent with studies performed in non-human primates, suggesting that chronic LFP stability trends are similar across both animal models.