8 June 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
JGJohn Gamelin
John Gamelin
AMAnastasios Maurudis
Anastasios Maurudis
AAAndres Aguirre
Andres Aguirre
Fei HuangFei Huang
Fei Huang
PGPuyun Guo
Puyun Guo
QZQuing Zhu Zhu
Quing Zhu Zhu
A real-time 512-element photoacoustic tomography system for small animal imaging using a ring ultrasound array has been developed. The system, based upon a 5 MHz transducer array formed along a 50 mm circular aperture, achieves sub-200 micron lateral resolution over a 2 cm disk-shaped region. Corresponding elevation resolutions of 0.6 to 2.5 mm over the central volume enable depth-resolved 3D tomographic imaging with linear translation. Using 8:1 electronic multiplexing, imaging at up to 8 frame/sec is demonstrated for both dynamic phantoms and in vivo mouse and brain samples. The real-time, full 2D tomographic capability of the system paves the way for functional photoacoustic tomographic imaging studies in small animals with sub-second time frame.

1 October 2005 in Radiology
Verified
Journal Article
Closed access
QZQuing Zhu Zhu
Quing Zhu Zhu
ECEdward B. Cronin
Edward B. Cronin
ACAllen A. Currier
Allen A. Currier
HVHugh S. Vine
Hugh S. Vine
MHMinming Huang
Minming Huang
CXChen Xu
Chen Xu
PURPOSE To investigate prospectively the feasibility of using optical tomography with ultrasonographic (US) localization to differentiate malignant from benign breast masses and to compare optical ...

1 March 2005 in Neoplasia
Verified
Journal Article
Open access
QZQuing Zhu Zhu
Quing Zhu Zhu
SKScott H. Kurtzman
Scott H. Kurtzman
PHPoornima Hegde
Poornima Hegde
STSusan Tannenbaum
Susan Tannenbaum
MKMark Kane
Mark Kane
KZKristen Zarfos
Kristen Zarfos
Angiogenesis in advanced breast cancers is highly distorted and heterogeneous. Noninvasive imaging that can monitor angiogenesis may be invaluable initially for diagnosis and then for assessing tumor response to treatment. By combining ultrasound (US) and near-infrared (NIR) optical imaging, a reliable new technique has emerged for localizing and characterizing tumor angiogenesis within the breast. This new technique employs a commercial US transducer coupled with an array of NIR optical fibers mounted on a hand-held probe. The US image is used for lesion localization and for guiding optical imaging reconstruction. Optical sensors are used for imaging tumor total hemoglobin distribution, which is directly related to tumor angiogenesis. Six large breast carcinomas were studied and microvessel density count was then performed on tissue samples obtained from these cancers. Two patients had locally advanced breast cancers and received neoadjuvant chemotherapy for 3 months. In one patient, before chemotherapy, the total hemoglobin distribution showed a high concentration at the cancer periphery; the distribution was later confined to the core area after 3 months of treatment. In another patient, as treatment progressed, the maximum hemoglobin concentration decreased from 255.3, to 147.5, to 76.9 micromol/l with an associated reduction in spatial extension. The other four patients had cancers of 2.0 to 3.0 cm in size and were imaged either at the time of core biopsy or definitive surgery. The histologic microvessel density counts from these tumor samples correlate to hemoglobin distributions with a correlation coefficient of 0.64 (P < .05). These initial results suggest that this new imaging technique may have great potential in imaging the heterogeneous vascular distribution of larger breast cancers in vivo and in monitoring treatment-related changes in angiogenesis during chemotherapy.

1 September 2003 in Neoplasia
Verified
Journal Article
Open access
QZQuing Zhu Zhu
Quing Zhu Zhu
MHMinming Huang
Minming Huang
NCNanGuang Chen
NanGuang Chen
KZKristen Zarfos
Kristen Zarfos
BJBipin Jagjivan
Bipin Jagjivan
SKScott H. Kurtzman
Scott H. Kurtzman
The diagnosis of solid benign and malignant tumors presents a unique challenge to all noninvasive imaging modalities. Ultrasound is used in conjunction with mammography to differentiate simple cysts from solid lesions. However, the overlapping appearances of benign and malignant lesions make ultrasound less useful in differentiating solid lesions, resulting in a large number of benign biopsies. Optical tomography using near-infrared diffused light has great potential for imaging functional parameters of 1) tumor hemoglobin concentration, 2) oxygen saturation, and 3) metabolism, as well as other tumor distinguishing characteristics. These parameters can differentiate benign from malignant lesions. However, optical tomography, when used alone, suffers from low spatial resolution and target localization uncertainty due to intensive light scattering. Our aim is to combine diffused light imaging with ultrasound in a novel way for the detection and diagnosis of solid lesions. Initial findings of two early-stage invasive carcinomas, one combined fibroadenoma and fibrocystic change with scattered foci of lobular neoplasia/lobular carcinoma in situ, and 16 benign lesions are reported in this paper. The invasive cancer cases reveal about two-fold greater total hemoglobin concentration (mean 119 micromol) than benign cases (mean 67 micromol), and suggest that the discrimination of benign and malignant breast lesions might be enhanced by this type of achievable optical quantification with ultrasound localization. Furthermore, the small invasive cancers are well localized and have wavelength-dependent appearance in optical absorption maps, whereas the benign lesions appear diffused and relatively wavelength-independent.

1 January 2010 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CLChanghui Li
Changhui Li
AAAndres Aguirre
Andres Aguirre
JGJohn K. Gamelin
John K. Gamelin
AMAnastasios Maurudis
Anastasios Maurudis
QZQuing Zhu Zhu
Quing Zhu Zhu
LWLihong V. Wang
Lihong V. Wang
For the first time, the hemodynamics within the entire cerebral cortex of a mouse were studied by using photoacoustic tomography (PAT) in real time. The PAT system, based on a 512-element full-ring ultrasound array, received photoacoustic signals primarily from a slice of 2-mm thickness. This system can provide high-resolution brain vasculature images. We also monitored the fast wash-in process of a photoacoustic contrast agent in the mouse brain. Our results demonstrated that PAT is a powerful imaging modality that can be potentially used to study small animal neurofunctional activities. Li, Aguirre, Gamelin, Maurudis, Zhu, and Wang: Real-time photoacoustic tomography of cortical hemodynamics in small animals Photoacoustic tomography (PAT) images embedded targets that absorb electromagnetic (EM) waves. Unlike other pure optical and microwave imaging methods, PAT uses an EM wave as the illumination source but detects the ultrasound waves generated from the photoacoustic (PA) effect.1, 2, 3 The mechanism of the PA effect is based on the thermal expansion associated with the heating process after EM absorption by the target. Images are formed by acquiring PA signals from multiple positions over the tissue surface. This imaging modality combines the advantages of optical and ultrasound imaging modalities: high optical contrast as well as scalable ultrasound resolution and imaging depth. Moreover, PAT is noninvasive, is nonionizing, and can image tissues in vivo. Over the past decade, it has been successfully applied in imaging both animal and human tissues.4, 5, 6 One of the most successful applications of PAT is to image small animal brains noninvasively. Compared with other noninvasive pure optical imaging methods, such as the recently developed optical microangiography,7 PAT not only images deeper, but also measures functions. Various PAT systems have been developed, including mechanically scanning with a single ultrasonic transducer8, 9, 10 or a linear ultrasound array,11 and optical scanning based on a Fabry-Pérot interferometer.12 However, the temporal resolution was poor in most previous PAT systems, where minutes or longer were normally required to acquire one high-quality image of the entire cortex. Recently, a new full-ring array PAT system was developed to specifically address this challenge.13 Both phantom and animal experiments have demonstrated that this full-ring array system can provide high-quality images in much less time. Using this system, we report our studies of real-time functional imaging of the entire cortical region of a mouse in vivo. We briefly introduce the imaging system and the contrast agent. Then, we describe the experiment of imaging the cortex of a mouse in vivo, discuss the results, and reach several conclusions. The primary part of the PA imaging system is a 512-element full-ring array. The diameter of the ring is 5cm , and the center frequency of each element is about 5MHz . In addition, each array element is cylindrically focused, forming an imaging slice of about 2-mm thickness. Although all 512 channels were equipped with preamplifiers for optimizing signal-to-noise ratio (SNR) at the front end and received PA signals in parallel, the secondary stage amplifiers and analog-to-digital converters have only 64 channels. Thus, for each laser shot, one-eighth of detection channels were recorded, and a complete 2-D scan requires eight laser shots. Figure 1 shows the top and side views of the array system. This system can also provide 3-D photoacoustic images by vertically scanning samples. More technical details of the system are described in Ref. 13. <!-- named anchor --> Fig. 1 Full-ring array PAT system. (a) Top view of the full-ring array and the animal head. (b) Side view of the array system and the position of the animal. The illumination source is a tunable pulsed laser system based on an optical parametric oscillator (OPO; Vibrant HE 315I, Opotek, Inc.). The laser pulse has a repetition rate of 10Hz and a pulse width of 5ns . Two wavelengths, 532nm and 620nm , were used to image the animal. After collimation, the laser beam was homogenized by passing it through a ground glass before it reached the tissue surface. The fluence of every laser pulse on the tissue was well below 20mJ∕cm2 , the American National Standards Institute (ANSI) safety standard. This system required a temporal interval greater than 0.125s between two successive data acquisitions, which is greater than the laser pulse interval (0.1s) . Thus, only every other laser shot was actually used in data acquisition, reducing the frame rate to 0.625Hz without averaging. (As mentioned, eight shots are required for a complete scan.) The contrast agent used in the following in vivo animal experiment was Evans blue, a dye that tightly binds to serum albumin in the vasculature. This dye has been used to determine blood volume and also to study the blood-brain barrier, since albumin cannot diffuse to the cerebrospinal fluid. We chose this dye because its absorption spectrum has a peak around 620nm (Ref. 14), where the blood absorption is relatively low. Moreover, the fast uptake of the Evans blue makes it a good model to demonstrate the in vivo imaging speed advantage of the system. The cerebral cortex of a Swiss Webster mouse (Harlan Sprague Dawley, Inc., Indianapolis, ∼23g ) was imaged in vivo. Before the experiment, the hair on the mouse head was gently depilated by using a hair removal lotion, as shown in Fig. 1, and a layer of ultrasound gelatin was applied. Then the mouse was fixed in a homemade animal holder, with its head covered by a thin transparent plastic membrane, and protruding into the imaging plane. To keep the animal motionless, oxygen was supplied with 1% isoflurane via a homemade breathing mask during the experiment. All experimental animal procedures conformed to the National Institutes of Health (NIH) guidelines and were in compliance with the Washington University Institutional Animal Care and Use Committee (IACUC). Before the administration of the contrast agent, the cortical vascular structure was imaged noninvasively at 532-nm wavelength, as shown in Fig. 2 . For comparison, an open-scalp anatomical photograph of the cortex vasculature was taken [Fig. 2] after the experiment and mouse euthanasia. Since blood has strong absorption at this wavelength, the blood vessels in the reconstructed image have a high contrast. Cortical vascular structures in mice are not anatomically identical. For instance, Figs. 2 and 2 present the PA image of another mouse (weight 19.7g ) and the anatomical photograph. <!-- named anchor --> Fig. 2 Noninvasive cortical vascular structural imaging of two mice. (a) and (c): The PA images obtained at 532-nm wavelength. (b and d): Photographs of the cortexes corresponding to (a) and (c). The photographs were taken with the scalps removed after the mouse was euthanized. To monitor the wash-in process of the contrast dye, about 0.1ml of Evans blue dye at 3% concentration was administered through tail vein injection. The entire cortical region was continuously imaged at a fixed position at 620-nm wavelength. The adminstration started at approximately 10s after the experiment began and took about 70s . PA images were reconstructed offline. At 620-nm wavelength, the control image obtained before the injection, as shown in Fig. 3 , missed many fine structures due to much lower optical absorption compared with Fig. 2. With the increase in the optical absorption by Evans blue at this wavelength, more vascular structures appeared, as shown in Fig. 3. The contrast agent wash-in dynamics are shown in Figs. 3, 3, 3, which plot the differences between the pixel values in the subsequent images and the control image at three different times. In addition, we calculated the integral of the pixel values within a square area of 1mm2 , as marked in Fig. 3, and normalized the result by the value of the control image [Fig. 3]. All PA images were obtained without averaging. <!-- named anchor --> Fig. 3 Noninvasive imaging of the wash-in process of Evans blue in cortical vasculature. (a) and (b): The PA images obtained before and after the dye injection. (c), (d), (e): PA image differences relative to (a) at time 32s , 56s , and 80s , respectively. All these images were obtained at 620-nm wavelength. (f) The normalized value of the integral of the pixel values within the marked square area in (a) versus time. (Color online only.) The Evans blue dye in the blood vessels helped to recover fine vascular structures in the PA image at 620-nm wavelength, as shown in Fig. 3. The increase in the PA image values in both the hemispherical and the cerebellar vasculature is plotted in Figs. 3, 3, 3, demonstrating the increase in the dye concentration within the cortex blood vessels. Figure 3 demonstrated a more than 100% increase in the pixel values in the selected sample region. More vascular structures could be recovered by increasing the amount or the concentration of Evans blue. The fluctuation in Fig. 3 is possibly due to breathing motion and motion stimulated by the injection, as both can alter the mouse’s position and thus affect the reconstructed images. Although only several sample PA images were provided, the images were continuously acquired at 1.6s /frame. The image reconstruction is based on the solid-angle-weighted reconstruction algorithm.15 Due to the limited-view scanning geometry and the finite bandwidth of the system response, some of the reconstructed image pixels have nonphysical negative values, which were removed in the image processing. The changes in the PA value, as in Figs. 3, 3, 3, denote the relative variances in the initial PA pressure, which are proportional to the changes in the optical absorption. For the first time, we obtained real-time PA functional imaging of the hemodynamics of the entire mouse cortex in vivo. We imaged the wash-in process of Evans blue contrast dye in the cortex vasculature. The temporal resolution of 1.6s can be further improved to about 1s by using a laser source with a more appropriate repetition rate. Substantial improvement in the imaging speed could be achieved by adding more parallel data acquisition channels or using an iterative reconstruction algorithm with fewer required data acquisitions, such as the compressed-sensing method.16 Our results demonstrated that array-based PAT can be a powerful candidate for studying various neurofunctional activities, such as epilepsy, which induce changes in the vasculature system. <!-- named anchor --> Acknowledgments We thank Yu Wang and Junjie Yao for helpful discussions. This work has been supported in part by National Institutes of Health Grant Nos. R01 EB000712, R01 EB008085, and U54 CA136398 (Network for Translational Research). L.W. has a financial interest in Microphotoacoustics, Inc., and Endra, Inc. which, however, did not support this work. <!-- named anchor --> <!-- named anchor --> References <!-- named anchor --> 1. <!-- named anchor --> A. Oraevsky and A. Karabutov, “Optoacoustic tomography,” in Biomedical Photonics Handbook, T. Vo-Dinh, Ed., Chap. 34, pp. 1–34, CRC, Boca Raton, FL (2003). Google Scholar <!-- named anchor --> 2. <!-- named anchor --> L. V. Wang and H. Wu, Biomedical Optics:Principles and Imaging, Wiley, Hoboken, NJ (2007). Google Scholar <!-- named anchor --> 3. <!-- named anchor --> Lihong V. Wang, Ed. Photoacoustic Imaging and Spectroscopy, 1st ed., CRC Press, Boca Raton, FL (2009). Google Scholar <!-- named anchor --> 4. <!-- named anchor --> M. Xu and L. V. Wang, “Photoacoustic imaging in biomedicine,” Rev. Sci. Instrum.0034-6748 77, 41101–41122 (2006). 10.1063/1.2195024 Google Scholar <!-- named anchor --> 5. <!-- named anchor --> C. Li and L. V. Wang, “Photoacoustic tomography and sensing in biomedicine,” Phys. Med. Biol.0031-9155 54, R59–R97 (2009). 10.1088/0031-9155/54/19/R01 Google Scholar <!-- named anchor --> 6. <!-- named anchor --> L. V. Wang, “Multiscale photoacoustic microscopy and computed tomography,” Nat. Photonics1749-4885 3(9), 503–509 (2009). 10.1038/nphoton.2009.157 Google Scholar <!-- named anchor --> 7. <!-- named anchor --> R. K. K. Wang and S. Hurst, “Mapping of cerebro-vascular blood perfusion in mice with skin and skull intact by optical micro-angiography at 1.3μm wavelength,” Opt. Express1094-4087 15(18), 11402–11412 (2007). 10.1364/OE.15.011402 Google Scholar <!-- named anchor --> 8. <!-- named anchor --> X. D. Wang, Y. J. Pang, G. Ku, X. Y. Xie, G. Stoica, and L. H. V. Wang, “Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain,” Nat. Biotechnol.1087-0156 21(7), 803–806 (2003). 10.1038/nbt839 Google Scholar <!-- named anchor --> 9. <!-- named anchor --> E. W. Stein, K. Maslov, and L. H. V. Wang, “Noninvasive, in vivo imaging of the mouse brain using photoacoustic microscopy,” J. Appl. Phys.0021-8979 105(10), 102027 (2009). 10.1063/1.3116134 Google Scholar <!-- named anchor --> 10. <!-- named anchor --> S. Yang, D. Xing, Q. Zhou, L. Xiang, and Y. Lao, “Functional imaging of cerebrovascular activities in small animals using high-resolution photoacoustic tomography,” Med. Phys.0094-2405 34(8), 3294–3301 (2007). 10.1118/1.2757088 Google Scholar <!-- named anchor --> 11. <!-- named anchor --> D. W. Yang, D. Xing, S. H. Yang, and L. Z. Xiang, “Fast full-view photoacoustic imaging by combined scanning with a linear transducer array,” Opt. Express1094-4087 15(23), 15566–15575 (2007). 10.1364/OE.15.015566 Google Scholar <!-- named anchor --> 12. <!-- named anchor --> J. Laufer, E. Zhang, G. Raivich, and P. Beard, “Three-dimensional noninvasive imaging of the vasculature in the mouse brain using a high-resolution photoacoustic scanner,” Int. J. Educational Telecommunications1077-9126 48, D299–D306 (2009). Google Scholar <!-- named anchor --> 13. <!-- named anchor --> J. Gamelin, A. Maurudis, A. Aguirre, F. Huang, P. Guo, L. V. Wang, and Q. Zhu, “A real-time photoacoustic tomography system for small animals,” Opt. Express1094-4087 17(13), 10489–10498 (2009). 10.1364/OE.17.010489 Google Scholar <!-- named anchor --> 14. <!-- named anchor --> C. E. Patterson, R. A. Rhoades, and J. G. N. Garcia, “Evans blue-dye as a marker of albumin clearance in cultured endothelial...

1 March 2003 in Optics Letters
Verified
Journal Article
Closed access
PDF file
QZQuing Zhu Zhu
Quing Zhu Zhu
NCNanguang Chen
Nanguang Chen
SKScott H. Kurtzman
Scott H. Kurtzman
A novel two-step reconstruction scheme using a combined near-infrared and ultrasound technique and its utility in imaging distributions of optical absorption and hemoglobin concentration of breast lesions are demonstrated. In the first-step image reconstruction, the entire tissue volume is segmented based on initial coregistered ultrasound measurements into lesion and background regions. Reconstruction is performed by use of a finer grid for lesion region and a coarse grid for the background tissue. As a result, the total number of voxels with unknown absorption can be maintained on the same order of total measurements, and the matrix with unknown total absorption distribution is appropriately scaled for inversion. In the second step, image reconstruction is refined by optimization of lesion parameters measured from ultrasound images. It is shown that detailed distributions of wavelength-dependent absorption and hemoglobin concentration of breast carcinoma can be obtained with the new reconstruction scheme.