Cheng-Shie Wuu

Dr. Cheng-Shie Wuu


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

13 January 2003 in Medical Physics
Verified
Journal Article
Closed access
CWCheng-Shie Wuu
Cheng-Shie Wuu
PSPeter Schiff
Peter Schiff
MMMarek J. Maryanski
Marek J. Maryanski
TLTian Liu
Tian Liu
SBScott Borzillary
Scott Borzillary
JWJudah Weinberger
Judah Weinberger


1 June 2000 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Open access
CWCheng-Shie Wuu
Cheng-Shie Wuu
RERonald D Ennis
Ronald D Ennis
PSPeter B Schiff
Peter B Schiff
ELEva K Lee
Eva K Lee
MZMarco Zaider
Marco Zaider
The dosimetric merit of a permanent prostate implant relies on two factors: the quality of the plan itself, and the fidelity of its implementation. The former factor depends on source type and on source strength, while the latter is a combination of skill and experience. The purpose of this study is to offer criteria by which to select a source type ((125)I or (103)Pd) and activity. Given a prescription dose and potential seed positions along needles, treatment plans were designed for a number of seed types and activities, specifically for (125)I with activities ranging from 0.3 to 0.7 mCi, and for (103)Pd with activities in the range of 0.8 to 1.6 mCi. To avoid human planner bias, an automated computerized planning system based on integer programming was used to obtain optimal seed configurations for each seed type and activity. To simulate the effect of seed-placement inaccuracies, random seed-displacement "errors" were generated for all plans. The displacement errors were assumed to be uniformly distributed within a cube with side equal to 2sigma. The resulting treatment plans were assessed using two volumetric and two dosimetric indices. For (125)I implants a coverage index (CI) of 98.5% or higher can be achieved for all activities (CI is the fraction of the target volume receiving the prescribed or larger dose). The external volume index (EI) (i.e., the amount of healthy tissue, as percentage of the target volume, receiving the prescribed or larger dose) increases from 13.9% to 20% as the activity increases from 0.3 to 0.7 mCi. For implants using (103)Pd, the external volume index increases from 10. 2% to 13.9% whenever CI exceeds 98.5%. Volumetric and dosimetric indices (coverage index, external volume index, D90, and D80) are all sensitive to seed displacement, although the activity dependence of these indices is more pronounced for (125)I than for (103)Pd implants. For both isotopes, the lower activities studied systematically result in lower EIs. If seeds can be placed within approximately 0.5 cm of their intended position (103)Pd should be preferred because its EI is lower than that of (125)I. For all activities the coverage indices and D90 are within the required range. If seed placement uncertainties are larger than 0.5 cm, (125)I provides slightly better target coverage; however, in terms of external volume (healthy tissue) covered, (103)Pd is superior to (125)I.

17 June 2011 in Radiation Measurements
Verified
Journal Article
Closed access
CWCheng-Shie Wuu
Cheng-Shie Wuu
YXY. Xu
Y. Xu

1 December 2006 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
CWCheng-Shie Wuu
Cheng-Shie Wuu
JCJing Chen
Jing Chen
Both 125I and 103Pd sources have been widely used in the permanent prostate implant. An important consideration for the choice of brachytherapy sources is the relative biological effectiveness (RBE) for the source/seed used in the implantation. As RBE is closely related to the microdosimetric parameter, it is desirable to calculate the dose mean lineal energies for both 125I and 103Pd at various radial distances to the seed surface. Monte Carlo simulation was performed for photons emitted from 125I and 103Pd. Energy depositions from photons and all their secondary electrons were tracked. Dose distributions of lineal energy, d(y), were calculated for spheres of 1 µm in diameter and at various radial distances to the seed surface. From the dose distribution of lineal energy, the dose mean lineal energy, yD, was derived. The results showed that the radiation qualities are constant in the distance range from 0.5 to 5 cm. In this distance range, the quality factor, relative to gamma rays from 60Co, is 2.2 for 125I and 2.5 for 103Pd.