The combustion diagnostics of rotating detonation engines (RDE) based on excited-state hydroxyl radical (OH*) chemiluminescence imaging is an important method used to characterize combustion flow fields. Overcoming the limitations of imaging devices to achieve nanosecond-scale temporal resolution is crucial for observing the propagation of high-frequency detonation waves. In this work, a nanosecond-scale imaging system with an ultra-high spatiotemporal resolution was designed and constructed. The system employs four near ultraviolet (NUV)-visible ICMOS, equipped with a high-gain, dual-microchannel plate (MCP) architecture fabricated using a new atomic layer deposition (ALD) process. The system has a maximum electronic gain of 107, a minimum integration time of 3 ns, a minimum interval time 4 ns, and an imaging resolution of 1608 × 1104 pixels. Using this system, high-spatiotemporal-resolution visualization experiments were conducted on RDE, fueled by H2–oxygen-enriched air and NH3–H2–oxygen-enriched air. The results enable the observation of the detonation wave structure, the cellular structure, and the propagation velocity. In combination with optical flow analysis, the images reveal vortex structures embedded within the cellular structure. For NH3-H2 mixed fuel, the results indicate that detonation wave propagation is more unstable than in H2 combustion, with a larger bright gray area covering both the detonation wave and the product region. The experimental results demonstrate that high spatiotemporal OH* imaging enables non-contact, full-field measurements, providing valuable data for elucidating RDE combustion mechanisms, guiding model design, and supporting NH3 combustion applications.
Extreme combustion features strong unsteadiness, heterogeneity and multi-physics coupling, which is of great significance for advanced propulsion systems. High-performance sensing of such extreme combustion flow fields is critical to revealing physical mechanisms and capturing fine flow structures. However, it faces severe challenges: rich multi-band spectral characteristics require multi-spectral observation; ultra-transient processes demand high-frequency imaging; and high-performance photoelectric enhancement is necessary under short gate width and high frame rates. To solve these problems, this study developed a high-performance ultraviolet optical sensing system (HUOSS), which achieves megahertz-level imaging at a 1608 × 1104 full-frame resolution and provides a 107 electron gain in the ultraviolet band. The HUOSS has been applied to chemiluminescence sensing of a hydrogen/ammonia-air rotating detonation as a representative extreme combustion system. Based on the analysis of representative influencing factors (e.g., the transmission characteristic of the bandpass filter and the intensifier gate width) in the HUOSS, the filter transmission loss and its influence on the gate width settings have been revealed. From the chemiluminescence sensing images captured in the experiments, the fine structure and evolution of detonation waves have been clearly identified, verifying the high-speed imaging capability. Furthermore, simultaneous OH* and NH* multi-spectral observation has been realized, and the effects of ammonia addition have been analyzed, validating the multi-spectral diagnostic capacity of the system. This study provides an effective diagnostic method for extreme transient combustion research, and comprehensively verified the multi-spectral, extremely transient and high signal-to-noise ratio sensing capabilities of this system.