Ryszard Krawczyk Krawczyk

Prof. Dr. Ryszard Krawczyk Krawczyk


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2024 in Materials
Verified
Journal Article
Open access
PDF file
ŁRŁukasz Rawicki
Łukasz Rawicki
RKRyszard Krawczyk Krawczyk
Ryszard Krawczyk Krawczyk
JSJacek Słania
Jacek Słania
GPGrzegorz Peruń
Grzegorz Peruń
Grzegorz GolańskiGrzegorz Golański
Grzegorz Golański
KŁKatarzyna Łuczak
Katarzyna Łuczak
The purpose of the presented research was to determine the suitability of using ultrasonic testing (UT) to inspect heterogeneous, from a material point of view, welded joints on the example of the joints of a ferritic steel element with elements made of an austenitic steel. The echo technique with transverse (SEK) and longitudinal wave heads (SEL) addressed this issue. Due to the widespread use of 13CrMo4-5 and X2CrNiMo17-12-2 steel grades in the energy industry, they were selected as the test materials for the study. The objects of the presented research were welded joint specimens with thicknesses of 8, 12, and 16 mm and dimensions of 300 × 300 mm, made using the 135 metal active gas (MAG) process with the use of the Lincoln 309LSi wire—a ferritic–austenitic filler material. The stages of the research task were (1) making distance–amplitude curve (DAC) patterns from the test materials; (2) preparation of specimens of welded joints with artificial discontinuities in the form of through-holes; (3) performing UT tests on welded joints with artificial discontinuities using heads with 60° and 70° angles for the transverse wave and angle heads for longitudinal waves with similar beam insertion angles; (4) selection, by radiographic testing (RT), of welded joint specimens with natural discontinuities in the form of a lack of sidewall fusion; (5) performing UT tests on welded joints with natural discontinuities, using heads as welded joints with artificial discontinuities. It was found that (1) the highest sensitivity of discontinuity detection was obtained by performing tests on the ferritic steel side, which is due to the lower attenuation of the ultrasonic wave propagating in ferritic steel compared to austenitic steel; (2) the best detection of discontinuities could be obtained using a longitudinal ultrasonic wave; (3) there is a relationship between the thickness of the welded elements, the angle of the ultrasonic beam introduction, and the effectiveness of discontinuity detection.

13 January 2026 in Materials
Verified
Journal Article
Open access
PDF file
Jarosław MichałekJarosław Michałek
Jarosław Michałek
RKRyszard Krawczyk Krawczyk
Ryszard Krawczyk Krawczyk
Steel and prestressed concrete traction poles can be fixed to reinforced concrete pile foundations using typical bolted connections. The stainless steel fastening screw is connected to the ordinary steel foundation pile reinforcement by friction welding under specific friction welding process parameters. From the perspective of the structural strength of the connection between the traction pole and the foundation pile, regarding the transfer of tensile and shear forces through a single anchor bolt, the yield strength of stainless steel bolts should be Re,min ≥ 345 MPa for M30 anchors, Re,min ≥ 310 MPa for M36 anchors and Re,min ≥ 300 MPa for M42 anchors. This requirement is reliably met by martensitic stainless steels, while other stainless steels have yield strengths below the required minimum. What truly determines the foundation pile’s load capacity is not the satisfactory mechanical strength of the stainless steel (here, the parameters are met), but the quality of the friction-welded end connection between the reinforcement and the threaded bars. Incorrect selection of the type of prestressing steel in the analyzed connection can have enormous consequences for foundation pile manufacturers. Annual production of foundation piles amounts to thousands of units, and an incorrect decision made by the pile designer at the design stage can result in significant financial losses and a high risk to human life. This article presents the results of studies on friction-welded connections of M30, M36, and M42 threaded bars made of austenitic 1.4301 (AISI 304) and martensitic 1.4021 (AISI 420) stainless steel with B500SP reinforcement bars. The tests yielded negative results for 1.4021 (AISI 420) steel, despite its yield strength exceeding Re ≥ 360 MPa.