With rising of the running speed of the train, the variation of pantograph-catenary contact force (PCCF) signal increases and the current collection quality between pantograph and catenary becomes worse. In order to explore the ways to optimize the PCCF signal, localization analysis of the value and the change of PCCF signal at the dropper-point are carried out using the method of simulation research in this paper. First, the continuous wavelet transform is adopted, and the variation of the PCCF signal of each dropper-point at the critical frequency is analyzed based on the time-frequency characteristics. It is obtained that the PCCF signal at the dropper-point is characterized by the amplitudes of the wavelength of dropper-spacing and span, in which the contribution degrees are different. Second, the methods of wavelet ridge and the Lipschitz exponents are adopted to analyze the change rate of PCCF signal based on the singularity. It is obtained that the declining rate of PCCF signal on the right side at the dropper-point is greater than the rising rate on the left side when the pantograph runs from the left of the dropper to the right. Finally, the relationship between the amplitude and the change rate of the PCCF signal and the catenary tension is discussed. The results show that increasing the contact wire tension and decreasing the messenger wire tension can reduce the value and the change rate of the PCCF signal at the dropper-points so that the current collection quality between pantograph and catenary is improved.
To improve the current collection quality between pantograph and catenary, model of catenary‐pantograph is established with the finite element simulation software MSC. Marc to calculate contact force between pantograph and catenary. Changes of contact force are discussed when the design parameters of catenary are changed. Interrelation between design parameter variation and contact force is analysed by introducing the method of Spearman rank correlation coefficient. Then, the sensitivity of the design parameters of catenary on contact force is analysed by introducing the method of Sobol sensitivity. Then, the variation of optimisation direction of design parameters of catenary and the influence of design parameters on contact force are analysed under different speeds. The results show the interrelation between design parameter variation and the contact force, and the sensitivity of parameter is different when the pantograph runs at the different speeds. Finally, the optimisation method of catenary parameters is proposed, and the current collection quality between pantograph and catenary is obviously improved by increasing the contact wire tension, reducing the contact wire linear density and messenger wire tension when the speed is 500 km/h.
30 April 2016 in Plasma Chemistry and Plasma Processing
Plasma surface modification plays a significant role in the field of surface treatment, and the dielectric barrier discharge in air is an important method to generate plasma. With the widespread use of photovoltaic (PV) power generation, the impact of PV panel dust deposition had on power generation efficiency could not be ignored. The traditional method of cleaning PV panel is a waste of water and not environmental, which makes it urgent to find a simple and effective cleaning method. Based on the specific scene of PV generation and the structure of PV panel, a special uneven electrode was designed to discharge and generate plasma to treat the PV panel. Meanwhile, to treat the PV panel with stubborn dusts adhering on the surface for a long time, a method that discharges in wet condition was proposed. The simulation in wet condition confirms the enhancement of electric field strength and the experiment verified its treatment effect. The treatment on clean PV panels made it the property of preventing dust from adhering; the treatment in wet condition removed most of the dusts; eventually, the experiment under sunshine proved that the electrodes designed had little impacts on PV panels' generation.