Sharda Yadav

Dr. Sharda Yadav

Queensland- Micro and Nanotechnology Centre, Griffith University, West Creek Road, Nathan, Queensland 4111, Australia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
AMAhmed Munaz
Ahmed Munaz
HMHajar Moghadas
Hajar Moghadas
Sharda YadavSharda Yadav
Sharda Yadav
MUMuhammad Umer
Muhammad Umer
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
Dermal interstitial fluid (ISF) is a novel source of biomarkers that can be considered as an alternative to blood sampling for disease diagnosis and treatment. Nevertheless, in vivo extraction and analysis of ISF are challenging. On the other hand, microneedle (MN) technology can address most of the challenges associated with dermal ISF extraction and is well suited for long-term, continuous ISF monitoring as well as in situ detection. In this review, we first briefly summarise the different dermal ISF collection methods and compare them with MN methods. Next, we elaborate on the design considerations and biocompatibility of MNs. Subsequently, the fabrication technologies of various MNs used for dermal ISF extraction, including solid MNs, hollow MNs, porous MNs, and hydrogel MNs, are thoroughly explained. In addition, different sensing mechanisms of ISF detection are discussed in detail. Subsequently, we identify the challenges and propose the possible solutions associated with ISF extraction. A detailed investigation is provided for the transport and sampling mechanism of ISF in vivo. Also, the current in vitro skin model integrated with the MN arrays is discussed. Finally, future directions to develop a point-of-care (POC) device to sample ISF are proposed.

28 July 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Sharda YadavSharda Yadav
Sharda Yadav
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
Liver cancer, especially hepatocellular carcinoma (HCC), is an aggressive disease with an extremely high mortality rate. Unfortunately, no promising markers are currently available for the early diagnosis of this disease. Thus, a reliable biomarker reflecting the early behaviour of the tumour will be valuable for diagnosis and treatment. The Ras homologous (Rho) GTPases, which belong to the small guanosine triphosphate (GTP) binding proteins, have been reported to play an important role in mediating liver cancer based on their important function in cytoskeletal reorganisation. These proteins can be either oncogenic or tumour suppressors. They are also associated with the acquirement of malignant features by cancer cells. The overexpression of RhoA and Rac1, members of the Rho GTPases, have been linked with carcinogenesis and the progression of different types of cancer. In the quest of elucidating the role of mechanical stimulation in the mechanobiology of liver cancer cells, this paper evaluates the effect of stretching on the expression levels of RhoA and Rac1 in different types of liver cancers. It is shown that that stretching liver cancer cells significantly increases the expression levels of RhoA and Rac1 in HCC and cholangiocarcinoma cell lines. We hypothesise that this relatively simple and sensitive method could be helpful for screening biological features and provide suitable treatment guidance for liver cancer patients.

10 August 2024 in Technologies
Verified
Journal Article
Open access
PDF file
HVHoang Huy Vu
Hoang Huy Vu
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
Sharda YadavSharda Yadav
Sharda Yadav
TNThi Thanh Ha Nguyen
Thi Thanh Ha Nguyen
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Microstructured surfaces are renowned for their unique properties, such as waterproofing and low adhesion, making them highly applicable in the biomedical field. These surfaces play a crucial role in influencing cell response by mimicking the native microenvironment of biological tissues. In this study, we engineered a series of biomimetic micropatterned surfaces using polydimethylsiloxane (PDMS) to explore their effects on primary breast cancer cell lines, contrasting these effects with those observed on conventional flat surfaces. The surface topography was varied to direct cells’ attachment, growth, and morphology. Our findings elucidate that surface-free energy is not merely a background factor but plays a decisive role in cell dynamics, strongly correlating with the spreading behaviour of breast cancer cells. Notably, on micropillar surfaces with high surface-free energy, an increase in the population of cancer cells was observed. Conversely, surfaces characterised by lower surface-free energies noted a reduction in cell viability. Moreover, the structural parameters, such as the gaps and diameters of the pillars, were found to critically influence cellular dispersion and adherence, underscoring the importance of the microstructures’ topography in biomedical applications. These insights pave the way for designing advanced microstructured surfaces tailored to specific cellular responses, opening new avenues for targeted cancer therapies and tissue engineering.

31 July 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Sharda YadavSharda Yadav
Sharda Yadav
PSPradip Singha
Pradip Singha
NNNhat-Khuong Nguyen
Nhat-Khuong Nguyen
Chin Hong OoiChin Hong Ooi
Chin Hong Ooi
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
Cellular response to mechanical stimuli is a crucial factor for maintaining cell homeostasis. The interaction between the extracellular matrix and mechanical stress plays a significant role in organizing the cytoskeleton and aligning cells. Tools that apply mechanical forces to cells and tissues, as well as those capable of measuring the mechanical properties of biological cells, have greatly contributed to our understanding of fundamental mechanobiology. These tools have been extensively employed to unveil the substantial influence of mechanical cues on the development and progression of various diseases. In this report, we present an economical and high-performance uniaxial cell stretching device. This paper reports the detailed operation concept of the device, experimental design, and characterization. The device was tested with MDA-MB-231 breast cancer cells. The experimental results agree well with previously documented morphological changes resulting from stretching forces on cancer cells. Remarkably, our new device demonstrates comparable cellular changes within 30 min compared with the previous 2 h stretching duration. This third-generation device significantly improved the stretching capabilities compared with its previous counterparts, resulting in a remarkable reduction in stretching time and a substantial increase in overall efficiency. Moreover, the device design incorporates an open-source software interface, facilitating convenient parameter adjustments such as strain, stretching speed, frequency, and duration. Its versatility enables seamless integration with various optical microscopes, thereby yielding novel insights into the realm of mechanobiology.

18 June 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
HVHoang Huy Vu
Hoang Huy Vu
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
Sharda YadavSharda Yadav
Sharda Yadav
TNThi Thanh Ha Nguyen
Thi Thanh Ha Nguyen
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Microstructured surfaces are renowned for their unique properties, such as waterproofing and low adhesion, making them highly applicable in the biomedical field. These surfaces play a crucial role in influencing cell response by mimicking the native microenvironment of biological tissues. In this study, we engineered a series of biomimetic micropatterned surfaces using polydimethylsiloxane (PDMS) to explore their effects on primary breast cancer cell lines, contrasting these effects with those observed on conventional flat surfaces. The surface topography was varied to direct cells’ attachment, growth, and morphology. Our findings elucidate that surface-free energy is not merely a background factor but plays a decisive role in cell dynamics, strongly correlating with the spreading behaviour of breast cancer cells. Notably, on micropillar surfaces with high surface-free energy, an increase in the population of cancer cells was observed. Conversely, surfaces characterised by lower surface-free energies noted a reduction in cell viability. Moreover, the structural parameters, such as the gaps and diameters of the pillars, were found to critically influence cellular dispersion and adherence, underscoring the importance of the microstructures’ topography in biomedical applications. These insights pave the way for designing advanced microstructured surfaces tailored to specific cellular responses, opening new avenues for targeted cancer therapies and tissue engineering.

5 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Sharda YadavSharda Yadav
Sharda Yadav
PSPradip Singha
Pradip Singha
NNNhat-Khuong Nguyen
Nhat-Khuong Nguyen
Chin Hong OoiChin Hong Ooi
Chin Hong Ooi
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
Cellular response to mechanical stimuli is a crucial factor for maintaining cell homeostasis. The interaction between extracellular matrix and mechanical stress plays a significant role in organ-izing the cytoskeleton and aligning cells. Tools that apply mechanical forces to cells and tissues, as well as those capable of measuring the mechanical properties of biological cells, have greatly contributed to our understanding of fundamental mechanobiology. These tools have been exten-sively employed to unveil the substantial influence of mechanical cues on the development and progression of various diseases. In this report, we present an economical and high-performance uniaxial cell stretching device. This paper reports the detailed operation concept of the device, ex-perimental design, and characterization. The device was tested with MDA-MB-231 breast cancer cells. Experimental results agree well with previously documented morphological changes re-sulting from stretching forces on cancer cells. Remarkably, our new device demonstrates compa-rable cellular changes within a 30-minute compared to the previous 2-hour stretching duration. Moreover, the device design incorporates an open-source software interface, facilitating conven-ient parameter adjustments such as strain, stretching speed, frequency, and duration. Its versatil-ity enables seamless integration with various optical microscopes, thereby yielding novel insights into the realm of mechanobiology.