Mahmoud Shahbazi

Dr. Mahmoud Shahbazi

Department of Engineering, Durham University, Durham, UK

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MSMahmoud Shahbazi
Mahmoud Shahbazi
EJEhsan Jamshidpour
Ehsan Jamshidpour
PPPhilippe Poure
Philippe Poure
SSShahrokh Saadate
Shahrokh Saadate
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
Fault detection (FD) in power electronic converters is necessary in embedded and safety critical applications to prevent further damage. Fast FD is a mandatory step in order to make a suitable response to a fault in one of the semiconductor devices. The aim of this study is to present a fast yet robust method for fault diagnosis in nonisolated dc-dc converters. FD is based on time and current criteria which observe the slope of the inductor current over the time. It is realized by using a hybrid structure via coordinated operation of two FD subsystems that work in parallel. No additional sensors, which increase system cost and reduce reliability, are required for this detection method. For validation, computer simulations are first carried out. The proposed detection scheme is validated on a boost converter. Effects of input disturbances and the closed-loop control are also considered. In the experimental setup, a field programmable gate array digital target is used for the implementation of the proposed method, to perform a very fast switch FD. Results show that, with the presented method, FD is robust and can be done in a few microseconds.

18 May 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MSMahmoud Shahbazi
Mahmoud Shahbazi
PPPhilippe Poure
Philippe Poure
SSShahrokh Saadate
Shahrokh Saadate
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
In this paper, an FPGA-based fault-tolerant back-to-back converter without redundancy is studied. Before fault occurrence, the fault-tolerant converter operates like a conventional back-to-back six-leg converter, and after the fault, it becomes a five-leg converter. Design, implementation, and experimental verification of an FPGA-based reconfigurable control strategy for this converter are discussed. This reconfigurable control strategy allows the continuous operation of the converter with minimum affection from a fault in one of the semiconductor switches. A very fast detection scheme is used to detect and locate the fault. Implementation of the fault detection and of the fully digital control schemes on a single FPGA is realized, based on a suited methodology for rapid prototyping. FPGA in loop and also experimental tests are carried out, and the results are presented. These results confirm the capability of the proposed reconfigurable control and fault-tolerant structure.

1 August 2019 in Renewable Energy
Verified
Journal Article
Open access
GGGolara Ghasemi
Golara Ghasemi
Younes NoorollahiYounes Noorollahi
Younes Noorollahi
HAHamed Alavi
Hamed Alavi
MMMousa Marzband
Mousa Marzband
MSMahmoud Shahbazi
Mahmoud Shahbazi

22 November 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SOSaeed Ouni
Saeed Ouni
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
MKMasih Khodabandeh
Masih Khodabandeh
MSMahmoud Shahbazi
Mahmoud Shahbazi
Jose RodriguezJose Rodriguez
Jose Rodriguez
ASAndres Ulloa Schmeisser
Andres Ulloa Schmeisser
This paper is focused on improving the post-fault performance of cascaded H-bridge multilevel inverters by decreasing the common-mode voltage. First, an algorithm is proposed to determine the optimal post-fault state among all possible states, which have the same maximum available voltage. Furthermore, a modified technique is proposed to calculate the references of inverter phase voltages under faulty conditions. This technique leads to a decrease in the common-mode voltage when the required output voltage is less than its maximum value. These solutions are mutually employed in the post-fault control system. Simulation and experimental results confirm the effectiveness of the proposed solutions in comparison with the existing methods in different cases.

20 July 2012 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
MSMahmoud Shahbazi
Mahmoud Shahbazi
PPPhilippe Poure
Philippe Poure
SSShahrokh Saadate
Shahrokh Saadate
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
Fast fault detection (FD) and reconfiguration is necessary for fault tolerant power electronic converters in safety critical applications to prevent further damage and to make the continuity of service possible. The aim of this study is to minimize the number of the used additional voltage sensors in a fault tolerant three-phase converter. In this paper, first a practical implementation of a very fast FD scheme with reduced sensor number is discussed. Then, an optimization in this scheme is also presented to decrease the detection time. For FD, special time and voltage criterion are applied to observe the error in the estimated phase-to-phase voltages for a specific period of time. The proposed optimization is based on the fact that following a detectable fault, two line-to-line voltages will deviate from their respective estimated values. Fault detection is studied for a three-leg two-level fault tolerant converter. Control and FD systems are implemented on a single field-programmable gate array. First, hardware in the loop experiments are carried out to evaluate the implemented schemes. Then, fully experimental tests are performed. The results confirm good performance of the proposed detection schemes, the digital controller and the fault tolerant structure. It is shown that such methods can detect and locate a fault in a few tens of microseconds. In certain cases the optimized scheme can be faster up to 50%, and in the other cases they have the same detection time.

22 March 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MSMahmoud Shahbazi
Mahmoud Shahbazi
PPPhilippe Poure
Philippe Poure
SSShahrokh Saadate
Shahrokh Saadate
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
Fast fault detection and reconfiguration of power converters is necessary in electrical drives to prevent further damage and to make the continuity of service possible. On the other hand, component minimized converters may provide the benefits of higher reliability and less volume and cost. In this paper, a new fault-tolerant converter topology is studied. This converter has five legs before the fault occurrence, and after fault detection the converter continues to function with four legs. A very fast fault detection and reconfiguration scheme is presented and studied. Simulations and experimental tests are performed to evaluate the structure requirements, the digital reconfigurable controller, and fault detection scheme. For experimental tests, the control and the fault detection and reconfiguration schemes are implemented on a single field-programmable gate array (FPGA) chip. Experimental and simulation results show the effectiveness of the proposed fault-tolerant topology and its FPGA-based control.