Hervé Carrier

Prof. Hervé Carrier


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

12 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
MCMaxime Cachia
Maxime Cachia
HCHervé Carrier
Hervé Carrier
Brice BouyssiereBrice Bouyssiere
Brice Bouyssiere
Philippe Le CoustumerPhilippe Le Coustumer
Philippe Le Coustumer
PCPierre Chiquet
Pierre Chiquet
IHIsabelle Le Hécho
Isabelle Le Hécho
This paper aims to provide the elemental composition of particles found in natural gas. Particle sampling is performed on cellulose filters obtained from an industrial gas storage facility, and the qualitative particle composition is determined by scanning electron microscopy and energy dispersive X-ray spectroscopy. Our results establish that natural gas may contain solid particles, with sizes ranging from less than 1 μm to more than 50 μm. The observed particles are composed of numerous elements, such as aluminum (Al), silica (Si), sulphur (S), chloride (Cl), chromium (Cr), zinc (Zn), sodium (Na), manganese (Mg), calcium (Ca), iron (Fe), titanium (Ti), nickel (Ni), vanadium (V), potassium (K), copper (Cu), manganese (Mn), silver (Ag), cobalt (Co), iodine (I), and barium (Ba), with relative occurrences ranging from 1 to 85%. Moreover, metallic elements enable the formation of larger particles as a result of the agglomeration of smaller particles.

25 March 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
ALAurore Lecharlier
Aurore Lecharlier
HCHervé Carrier
Hervé Carrier
Brice BouyssiereBrice Bouyssiere
Brice Bouyssiere
GCGuilhem Caumette
Guilhem Caumette
PCPierre Chiquet
Pierre Chiquet
IHIsabelle Le Hécho
Isabelle Le Hécho
In Europe, renewable energy gases such as biomethane are aimed at substituting natural gas provided their stringent compliance to natural gas quality standards stipulating maximal levels of several chemical trace compounds (TC). Preconcentration is generally required to detect TC and inasmuch as biomethane is compressed for injection in the natural gas grid, preconcentration is commonly either done by collecting the bulk pressurized gas in a high-pressure cylinder or by first depressurizing it to collect a bulk volume in e.g. a gas sampling bag. Such whole gas samples are then transported to the lab and transferred to a preconcentration unit, entailing contamination and TC loss risks. Therefore, here a novel handy field-portable device for the direct in situ high-pressure preconcentration of TC is presented, enabling to sample gases at pressures up to 200 bara through a self-assembled Tenax®TA + Carbopack™X multibed adsorbent tube. The effect of the gas sampling pressure on the preconcentration of TC on adsorbent tubes was evaluated using a synthetic gas mixture containing 41 halogenated volatile organic compounds each at 1 ppmmol in N2. At given normalized sampled volumes and in the pressure range 5–100 bara handled in French gas transport grids, the pressure had no influence on the preconcentration when the gas circulates through the adsorbent tubes and as long as the adsorbents are not saturated. Next, for the first time, a real biomethane stream was sampled using the novel direct high-pressure preconcentration method on Tenax®TA + Carbopack™X multibed adsorbent tubes, allowing to preconcentrate, in a single sampling run, a wide range of volatile organic TC. More than 26 distinct TC were detected, belonging to seven chemical families: alkenes, aromatics, alkanes (linear, cyclic and polycyclic), sulphur-compounds and terpenes, with linear alkanes (pentane, heptane, octane) and terpenes predominating. Semi-quantification indicated pentane, dimethylcyclopropane, hexane, heptane, octane, α-pinene and camphene are present at a ≤1 ppmmol concentration threshold in the biomethane.

18 April 2017 in The European Physical Journal Special Topics
Verified
Journal Article
Closed access
PDF file
EOEzequiel Orlandi
Ezequiel Orlandi
JDJean-Luc Daridon
Jean-Luc Daridon
HCHervé Carrier
Hervé Carrier

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
ALAurore Lecharlier
Aurore Lecharlier
HCHervé Carrier
Hervé Carrier
Brice BouyssiereBrice Bouyssiere
Brice Bouyssiere
GCGuilhem Caumette
Guilhem Caumette
PCPierre Chiquet
Pierre Chiquet
IHIsabelle Le Hécho
Isabelle Le Hécho
In Europe, renewable energy gases such as biomethane are aimed at substituting natural gas provided their stringent compliance to natural gas quality standards stipulating maximal levels of several chemical trace compounds. Preconcentration is generally required to detect trace compounds and inasmuch as biomethane is usually compressed for injection in the natural gas grid, preconcentration is commonly either done by collecting the bulk pressurized gas in a high-pressure cylinder or by first depressurizing it to collect a bulk volume in e.g. a gas sampling bag. Such whole gas samples must then be transported to the lab and transferred to a preconcentration unit, entailing contamination and trace compounds loss risks. Therefore, here a novel device for direct in situ high-pressure preconcentration is presented, enabling to sample gas at pressures up to 200 bar a through a self-assembled Tenax ® TA + Carbopack TM multibed adsorbent tube. The effect of the gas sampling pressure on the preconcentration of trace compounds on adsorbent tubes was evaluated using a synthetic gas mixture containing 41 halogenated volatile organic compounds each at 1 ppm mol in N 2 . At given normalized sampled volumes and in the pressure range 5 – 100 bar a , the pressure had no influence on the preconcentration when the gas circulates through the adsorbent tubes and as long as the adsorbents are not saturated. The high-pressure preconcentration is non-selective towards trace compounds and is equally efficient independently from the gas sampling pressure. Next, for the first time, a real biomethane stream was sampled using the novel direct high-pressure preconcentration method on Tenax ® TA + Carbopack TM multibed adsorbent tubes, allowing to preconcentrate, in a single sampling run, a wide range of volatile organic trace compounds. More than 26 distinct trace compounds were detected, belonging to seven chemical families: alkenes, aromatics, cyclo-alkanes, linear alkanes, polycyclic alkanes, Sulphur compounds and terpenes, with linear alkanes (pentane, heptane, octane) and terpenes predominating.

17 June 2025 in Ébullition(s) : le cahier illustré de la recherche
Verified
Journal Article
Closed access
IHIsabelle Le Hécho
Isabelle Le Hécho
Brice BouyssiereBrice Bouyssiere
Brice Bouyssiere
ALAurore Lecharlier
Aurore Lecharlier
HCHervé Carrier
Hervé Carrier
GCGuilhem Caumette
Guilhem Caumette
BDBapstiste Daspet
Bapstiste Daspet
Le biométhane, obtenu par purification du biogaz, est une alternative renouvelable au gaz naturel. Les recherches menées à l’UPPA avec Teréga se concentrent sur les composés traces présents dans le biogaz et le biométhane. Des méthodes innovantes de prélèvement et de préconcentration ont été développées pour piéger et analyser ces composés facilitant les contrôles de la qualité en amont ou en aval d’unités de traitement ou au niveau de l’injection du biométhane dans le réseau afin de garantir l’adéquation de sa qualité par rapport aux usages et à l’environnement.