The presence of natural organic matter (NOM) in water does not present direct risk to the human body or to the environment. However, its presence along with other pollutants can lead to countless issues and damage human health and the environment. The hydrodynamic cavitation (HC) phenomenon started being used in the early 21st century as a process capable of treating supply-water and wastewater based on pollutant and pathogen degradation. Process effectiveness increases when it is combined to chemical agents, creating an advanced oxidation process (AOP). Although several studies have presented broaden applications for the HC process, its use for NOM removal from supply-water was not yet assessed; therefore, it remains a gap in scientific knowledge. The aim of the current study is to assess HC potential in NOM removal. In order to do so, the experiments were carried out in bench scale hydrodynamic cavitation system operated at batch model within 15-min duration period-of-time. In addition, decantation experiments (24-h period-of-time) were performed in order to check HC influence on molecules found in reaction medium after the exposure of NOM to the phenomenon. NOM was produced by a synthetic humic acid (HA) matrix at fixed concentration of 100 ppm. In total, 16 experiments were carried out; each experiment was featured by the following pair: pH (2.6, 3.0, 3.5 and 5.5) and hydrogen peroxide (0, 1, 5 and 30 mL). The best removal efficiencies (34%-36%) were observed in the most acidic pH ranges (2.6-3.0) at H2O2 concentration of 15mL. Results have presented high NOM removal efficiency (approximately 90%) after decantation at the most acidic pH ranges, as well. It can be explained by the fact that hydrodynamic cavitation in acid solution can break molecular structures suspended in the liquid medium, which favors decantation. Based on the present study, hydrodynamic cavitation with hydrogen peroxide addition can remove NOM from water; moreover, pH control is an essential factor for process development.
4 December 2020 in Revista Eletrônica em Gestão, Educação e Tecnologia Ambiental
Hydrodynamic cavitation has been extensively studied for its potential to remove emerging pollutants. Despite the advance of the experimental studies involving this phenomenon, computational studies that evaluate the influence of the geometry of the cavitation devices on the flow parameters are still necessary. The purpose of this article was to evaluate the influence of the change in the geometry of a Venturi device on the volume of cavities formed in its divergent section using Computational Fluid Dynamics (CFD). The geometric parameters modified in the Venturi were: the diffuser angle and the relation between the height and the width of the throat (h/w). The volume of cavities is an important parameter because it influences the cavitation intensity. A cavitational bench system was constructed in order to obtain input data for simulation. The results showed that the increase in the diffuser angle from 6.5° to 18.5° gradually reduced the volume of cavities from 93 mm3 to 10 mm3. Between the relations h/w = 0.05 and h/w = 0.45 was observed the formation of cavities between 106 mm3 and 77 mm3, however between h/w = 0.45 and h/w = 1.0 there was the formation of 213 mm3. Therefore, Venturi’s with diffuser angle less than 6.5º and relation h/w greater than 0.45 produce greater volume of cavities. The greater volume of cavities will not necessarily produce greater cavitational intensity, since cavitation clouds can be formed and reduce the implosion intensity of the cavitation bubbles.
Humic substances (HSs) pose a significant challenge to safe drinking-water production due to their ubiquity, limited removal by conventional methods, and their role in forming toxic disinfection by-products, reinforcing the need for more efficient, energy-favorable, and scalable treatment technologies. This study developed and evaluated a compact hydrodynamic cavitation (HC) system that simultaneously induces coagulation and generates microbubbles for flotation-based HS removal. For the first time, HC is explored as a multifunctional unit capable of integrating rapid mixing, coagulant destabilization, and flotation within a single device. Optimal coagulation conditions were established at pH 5.0 and 9.5 mg L−1 of ferric chloride. Process optimization using a Rotated Central Composite Design demonstrated that inlet pressure, flotation time, and initial HS concentration were the dominant operational factors, enabling the HC system to achieve a maximum removal efficiency of 81.9%. Five Venturi geometries with divergent angles of 4°, 8°, 11°, 14°, and 90° were investigated, with the 8° Venturi exhibiting superior performance due to stable microbubble formation and effective coagulant dispersion, as confirmed by CFD analyses. Comparative tests with a conventional Flotest unit showed that achieving similar efficiencies required at least 30% saturated water. In contrast, the HC system delivered equivalent removal in continuous flow without external air saturation. These findings demonstrate the potential of HC as an integrated coagulation–flotation core and highlight its promise as a compact, energy-efficient, and scalable technology for natural organic matter removal in water treatment.
Atualmente, os resíduos sólidos produzidos e gerados trazem à tona a discussão e preocupação quanto à sua destinação e disposição final adequada. Res...