Evan Nicolai

Mr. Evan Nicolai


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
ENEvan Nicolai
Evan Nicolai
NMNicholas J. Michelson
Nicholas J. Michelson
MSMegan L. Settell
Megan L. Settell
SHSeth Hara
Seth Hara
JTJames Trevathan
James Trevathan
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
Implantable devices to measure neurochemical or electrical activity from the brain are mainstays of neuroscience research and have become increasingly utilized as enabling components of clinical therapies. In order to increase the number of recording channels on these devices while minimizing the immune response, flexible electrodes under 10 µm in diameter have been proposed as ideal next-generation neural interfaces. However, the representation of motion artifact during neurochemical or electrophysiological recordings using ultra-small, flexible electrodes remains unexplored. In this short communication, we characterize motion artifact generated by the movement of 7 µm diameter carbon fiber electrodes during electrophysiological recordings and fast-scan cyclic voltammetry (FSCV) measurements of electroactive neurochemicals. Through in vitro and in vivo experiments, we demonstrate that artifact induced by motion can be problematic to distinguish from the characteristic signals associated with recorded action potentials or neurochemical measurements. These results underscore that new electrode materials and recording paradigms can alter the representation of common sources of artifact in vivo and therefore must be carefully characterized.

2 November 2018 in bioRxiv
Verified
Preprint
Open access
PDF file
JTJames Trevathan
James Trevathan
AAAnders J Asp
Anders J Asp
ENEvan Nicolai
Evan Nicolai
JTJ. M. Trevathan
J. M. Trevathan
NKN.A. Kremer
N.A. Kremer
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
After decades of study in humans and animal models, there remains a lack of consensus regarding how the action of electrical stimulation on neuronal and non-neuronal elements – e.g. neuropil, cell bodies, glial cells, etc. – leads to the therapeutic effects of neuromodulation therapies. To further our understanding of neuromodulation therapies, there is a critical need for novel methodological approaches using state-of-the-art neuroscience tools to study neuromodulation therapy in preclinical models of disease. In this manuscript we outline one such approach combining chronic behaving single-photon microendoscope recordings in a pathological mouse model with electrical stimulation of a common deep brain stimulation (DBS) target. We describe in detail the steps necessary to realize this approach, as well as discuss key considerations for extending this experimental paradigm to other DBS targets for different therapeutic indications. Additionally, we make recommendations from our experience on implementing and validating the required combination of procedures that includes: the induction of a pathological model (6-OHDA model of Parkinson’s disease) through an injection procedure, the injection of the viral vector to induce GCaMP expression, the implantation of the GRIN lens and stimulation electrode, and the installation of a baseplate for mounting the microendoscope. We proactively identify unique data analysis confounds occurring due to the combination of electrical stimulation and optical recordings and outline an approach to address these confounds. In order to validate the technical feasibility of this unique combination of experimental methods, we present data to demonstrate that 1) despite the complex multifaceted surgical procedures, chronic optical recordings of hundreds of cells combined with stimulation is achievable over week long periods 2) this approach enables measurement of differences in DBS evoked neural activity between anesthetized and awake conditions and 3) this combination of techniques can be used to measure electrical stimulation induced changes in neural activity during behavior in a pathological mouse model. These findings are presented to underscore the feasibility and potential utility of minimally constrained optical recordings to elucidate the mechanisms of DBS therapies in animal models of disease.

13 February 2020 in Annals of Global Health
Verified
Journal Article
Open access
PDF file
AAAnders J. Asp
Anders J. Asp
CWChristina M. Webber
Christina M. Webber
ENEvan Nicolai
Evan Nicolai
GMGabriel Martínez-Gálvez
Gabriel Martínez-Gálvez
VMVictoria S. Marks
Victoria S. Marks
Luis LujanLuis Lujan
Luis Lujan
A clean and functional microscope is necessary for accurate diagnosis of infectious diseases. In tropical climates, high humidity levels and improper storage conditions allow for the accumulation of debris and fungus on the optical components of diagnostic equipment, such as microscopes. Our objective was to develop and implement a low-cost, sustainable, easy to manage, low-maintenance, passive humidity control chamber to both reduce debris accumulation and microbial growth onto the optical components of microscopes. Constructed from easily-sourced and locally available materials, the cost of each humidity control chamber is approximately $2.35 USD. Relative humidity levels were recorded every 30 minutes over a period of 10 weeks from two chambers deployed at the Belize Vector and Ecology Center and the University of Belize. The humidity control chamber deployed at the University of Belize maintained internal relative humidity at an average of 35.3% (SD = 4.2%) over 10 weeks, while the average external relative humidity was 86.4% (SD = 12.4%). The humidity control chamber deployed at the Belize Vector and Ecology Center effectively maintained internal relative humidity to an average of 54.5% (SD = 9.4%) over 10 weeks, while the average external relative humidity was 86.9% (SD = 12.9%). Control of relative humidity is paramount for the sustainability of medical equipment in tropical climates. The humidity control chambers reduced relative humidity to levels that were not conducive for fungal growth while reducing microscope contamination from external sources. This will likely extend the service life of the microscopes while taking advantage of low-cost, locally sourced components.