Tugberk Ozmen

Dr. Tugberk Ozmen

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Pamukkale University Journal of Engineering Sciences
Verified
Journal Article
Closed access
TOTugberk Ozmen
Tugberk Ozmen
ÜKÜzeyir Kuzu
Üzeyir Kuzu
YKYücel Koçyiğit
Yücel Koçyiğit
HSHaldun Sarnel
Haldun Sarnel
Pamukkale University Journal of Engineering Sciences

30 April 2021 in Balkan Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
TOTugberk Ozmen
Tugberk Ozmen
NONevzat Onat
Nevzat Onat
Permanent magnet synchronous generator is one of the generator types used in electrical energy production. In this study, a 1.5 kW inner rotor, surface located permanent magnet synchronous generator is used as a reference. The computer model of this generator has been prepared using Maxwell Rmxprt software. Rmxprt analysis of the generator has been performed and results were obtained for no-load and nominal load operating conditions. Parameters such as cogging torque which is an important parameter especially for permanent magnet synchronous generators used in wind turbines and efficiency were examined. The effects of changing in magnetic circuit as the permanent magnet pole arc to pole pitch ratio, magnet thickness and magnet material parameters on the generator performance were analyzed comparatively.

28 April 2022 in Akıllı Ulaşım Sistemleri ve Uygulamaları Dergisi
Verified
Journal Article
Open access
TOTugberk Ozmen
Tugberk Ozmen
EÖEce Özmen
Ece Özmen
STSezai Taskin
Sezai Taskin
SBSerdinç Bulut
Serdinç Bulut
Dünya ve ülkemiz kentlerinde nüfus artışına bağlı olarak ortaya çıkan talep ve ihtiyaçların karşılanması için çevre, enerji, toplum, yönetim, ulaşım gibi bileşenlerin teknolojik altyapı ile entegre edilmesi sayesinde akıllı şehir çözümleri geliştirilmektedir. Nüfus artışının gelecekte de devam edeceği öngörüsünden hareketle akıllı şehir çözümleriyle ilgili ulusal ve uluslararası düzeyde hayata geçirilen birçok proje ve hazırlanan mevzuat bulunmaktadır. Bu çalışmanın amacı, Manisa ili için akıllı şehir bileşenlerden biri olan akıllı ulaşım sistemlerine yönelik çözümlere dayalı öneri uygulamalar ve eylemlerin sunulmasıdır. Bu çalışmada Manisa Büyükşehir Belediyesi(Manisa BB) ulaşım planları ile uluslararası ve ulusal mevzuatlar kapsamında yapılan çalışmalar incelenmiştir. Elde edilen veriler analiz edilerek öneri uygulama ve eylemler tanımlanmışolup bunların uluslararası standartlar ve ulusal planlar ile uyumluluğu kıyaslanmıştır. Manisa kent merkezindeki ulaşım sorunlarının akıllı ulaşım yöntemleriyle çözülebilmesine yönelik bu çalışma kapsamında önerilen uygulama ve eylemlerin Ulusal kalkınma planını ve Manisa BB stratejik planını desteklediği, aynı zamanda ISO 37122 standardında yer alan akıllı şehirlerdeki on dört akıllı ulaşım göstergesinden yedisini sağladığı sonucuna ulaşılmıştır. Bu çalışmanın literatürde yapılan mevcut çalışmalardan farkı, yerel yönetimin yaptığı çalışmaların göz önünde bulundurulması, ülkemiz ve dünyadaki örnek uygulamaların incelenmesi yanı sıra ulusal hedefler ile uluslararası standartların sağlanabilmesi için uygulama önerilerinin sunulmasıdır.

21 April 2025 in Turkish Journal of Electrical Power and Energy Systems
Verified
Journal Article
Closed access
TOTugberk Ozmen
Tugberk Ozmen
TITayfun Isıkelekoglu
Tayfun Isıkelekoglu
SDSaid Tunahan Durmaz
Said Tunahan Durmaz
BEBatı Eren Ergun
Batı Eren Ergun
NONevzat Onat
Nevzat Onat
Mehmet Onur GulbahceMehmet Onur Gulbahce
Mehmet Onur Gulbahce
Flux-switching generators (FSGs) are widely used in wind turbine applications, particularly within microgrids, due to their unique structural and operational advantages. However, the salient pole structures of their stator and rotor teeth result in high torque ripple, elevated harmonic content, and increased magnetic flux density in the stator and rotor teeth. These issues necessitate optimization of the machine’s design parameters. This study investigates the effects of rotor pole skew (delta) and coil-pole pitch ratio (embrace) on the performance of a 260 W FSG operating at 1200 rpm and 200 Hz. A multi-slice skewing method was applied to the rotor to analyze its impact on average torque, torque ripple, and efficiency. The results reveal that variations in pole skew and coil-pole pitch ratio significantly affect torque, flux linkage, and induced voltage while also reducing magnetic stresses. Despite these improvements, the prominence of the second harmonic limits the effectiveness of the skewing angle on generator output parameters. Additionally, the influence of the number of rotor slices on output performance and manufacturing complexity was examined.Cite this article as: T. Ozmen, T. Isıkelekoglu, S. Tunahan Durmaz, B. Eren Ergun, and N. Onat, "Comprehensive analysis of rotor geometric parameters and skewing methods in flux-switching generators," Turk J Electr Power Energy Syst., Published online April 21, 2025. doi 10.5152/tepes.2025.25003.

24 June 2026 in Turkish Journal of Electrical Power and Energy Systems
Verified
Journal Article
Closed access
TOTugberk Ozmen
Tugberk Ozmen
HGHuseyin Engin Gulbahce
Huseyin Engin Gulbahce
ADAli Eren Dağ
Ali Eren Dağ
AAALTAY ARBAK
ALTAY ARBAK
Aliihsan KocaAliihsan Koca
Aliihsan Koca
Mehmet Onur GulbahceMehmet Onur Gulbahce
Mehmet Onur Gulbahce
Flux-switching permanent-magnet (FSPM) generators are gaining prominence in renewable energy applications due to their robust rotor structure and high-power density. However, thermal management remains a critical challenge, as excessive heat can degrade insulation and permanent magnet (PM) properties. This study presents a comprehensive thermal analysis of a 12-slot/10-pole FSPM generator using 3D Computational Fluid Dynamics (CFD) via ANSYS Icepak. Electromagnetic losses, including copper, core, and eddy-current losses, were integrated into the finite-volume formulation to solve for conduction, convection, and radiation effects. Simulation results identify the primary hotspots in the central axial region of the armature windings, reaching a peak steady-state temperature of 78 °C. The rotor and PMs exhibit strong thermal coupling, stabilizing within a range of 69 °C to 78 °C. Transient analysis confirms that all components reach thermal stability after approximately 90 minutes. The findings demonstrate that peak temperatures remain well below the critical limits for NdFeB magnets and Class F insulation, validating the thermal reliability of the proposed design for long-term operation.

29 December 2021 in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
Verified
Journal Article
Open access
PDF file
TOTugberk Ozmen
Tugberk Ozmen
NONevzat Onat
Nevzat Onat
One of the generator types used in producing electrical energy is permanent magnet synchronous generator (PMSG). In this study, a surface located permanent magnet synchronous machine with a 1.5 kW inner rotor was used as a reference generator. The finite element analysis of this generator was conducted via Maxwell Rmxprt software. As a result, phase current and voltages waveforms were measured at a rated load. The characteristics of the PMSG under loaded and unloaded working conditions were examined through the measurements on the experimental setup designed in Electrical Machines Laboratory at the Faculty of Engineering of Manisa Celal Bayar University. The values obtained from the open-circuit tests were compared with the simulation and manufacturer's catalog data. This paper also contrasted line voltages measured and simulated at 450 rpm as rated speed.