Hydrogels are excellent mimetics of mammalian extracellular matrices and have found widespread use in tissue engineering. Nanoporosity of monolithic bulk hydrogels, however, limits mass transport of key biomolecules. Microgels used in 3D bioprinting achieve both custom shape and vastly improved permissivity to an array of cell functions, however spherical‐microbead‐based bioinks are challenging to upscale, are inherently isotropic, and require secondary crosslinking. Here, bioinks based on high‐aspect‐ratio hydrogel microstrands are introduced to overcome these limitations. Pre‐crosslinked, bulk hydrogels are deconstructed into microstrands by sizing through a grid with apertures of 40–100 µm. The microstrands are moldable and form a porous, entangled structure, stable in aqueous medium without further crosslinking. Entangled microstrands have rheological properties characteristic of excellent bioinks for extrusion bioprinting. Furthermore, individual microstrands align during extrusion and facilitate the alignment of myotubes. Cells can be placed either inside or outside the hydrogel phase with >90% viability. Chondrocytes co‐printed with the microstrands deposit abundant extracellular matrix, resulting in a modulus increase from 2.7 to 780.2 kPa after 6 weeks of culture. This powerful approach to deconstruct bulk hydrogels into advanced bioinks is both scalable and versatile, representing an important toolbox for 3D bioprinting of architected hydrogels.
Achieving regeneration of articular cartilage is challenging due to the low healing capacity of the tissue. Appropriate selection of cell source, hydrogel, and scaffold materials are critical to obtain good integration and long‐term stability of implants in native tissues. Specifically, biomechanical stability and in vivo integration can be improved if the rate of degradation of the scaffold material matches the stiffening of the sample by extracellular matrix secretion of the encapsulated cells. To this end, a novel 3D‐printed lactide copolymer is presented as a reinforcement scaffold for an enzymatically crosslinked hyaluronic acid hydrogel. In this system, the biodegradable properties of the reinforced scaffold are matched to the matrix deposition of articular chondrocytes embedded in the hydrogel. The lactide reinforcement provides stability to the soft hydrogel in the early stages, allowing the composite to be directly implanted in vivo with no need for a preculture period. Compared to pure cellular hydrogels, maturation and matrix secretion remain unaffected by the reinforced scaffold. Furthermore, excellent biocompatibility and production of glycosaminoglycans and collagens are observed at all timepoints. Finally, in vivo subcutaneous implantation in nude mice shows cartilage‐like tissue maturation, indicating the possibility for the use of these composite materials in one‐step surgical procedures.
27 April 2025 in Progress in Additive Manufacturing
We introduce a novel in situ quality monitoring approach for the Laser Powder Bed Fusion (PBF-LB/M) process that operates independently of prior experimental data and can be integrated into existing systems. We employ a cost-effective, high-resolution CMOS camera coupled with a bright and darkfield lighting arrangement to acquire data layer-by-layer. Using computer vision techniques, specifically the GrabCut algorithm, we automate the inspection and the virtual reconstruction of fused part geometries. Our results, compared with nominal slice data and computed tomography scan data, indicate a robust accuracy in quantifying geometric deviations (mean deviation of 15.60 $$\upmu$$ m and 15.20 $$\upmu$$ m respectively, Jaccard scores of 0.99). The proposed training-free framework, unlike traditional machine learning methods, requires no labeled datasets or prior training, offering a cost-effective and adaptable solution. This eliminates the dependency on material, scan strategy, or part geometry, which typically hinders the scalability of conventional approaches. Additionally, our method facilitates automatic defect detection such as recoater strikes, recoater hopping, and powder shortages, with balanced accuracy scores of up to 0.87. These advantages highlight the framework’s potential as a practical tool for in situ process monitoring and quality assurance in PBF-LB/M systems.
The creation of multi‐tissue auricular transplants for the treatment of microtia is a challenge due to the complex and layered structure of this anatomical tissue. A novel casting technique for the 3D biofabrication of heterogeneous, multi‐layered, and human‐scale tissue transplants using eluting agarose molds is presented. The molds are generated by casting agarose into custom 3D‐printed containers, termed metamolds, optimized to facilitate the hydrogel casting process based on geometric and topological constraints. Casting yields high resolution (50 µm) and allows for subsequent casting of further hydrogel layers on the transplant. Multi‐layered auricular constructs are fabricated on a cartilage core consisting of a hyaluronic acid‐alginate double network and an adjacent gelatin‐based dermal layer. Bonding between adjacent layers is achieved by orthogonal physical and enzymatic crosslinking of residual functional groups between each layer. Material composition and culture duration are optimized for each layer allowing for maturation into cartilaginous and pre‐vascularized dermal tissues. To demonstrate the scalability of this technique for the biofabrication of human‐sized transplants, bi‐layered human‐sized ears are cast. Overall, this novel casting technique offers a promising approach for the fabrication of complex tissue grafts, overcoming the limitations of other traditional biofabrication methods.
Hydrogels are one of the most widespread biomaterials used in tissue engineering. However, they possess weak mechanical properties and are often unstable in load‐bearing applications in vivo. A novel class of flexible Ti–6Al–4V titanium alloy lattices manufactured using laser powder bed fusion (L‐PBF) serves as a tunable reinforcement for hydrogels, providing them with additional mechanical stability and flexibility, while ensuring biocompatibility. A study on the design parameters of the structural elements of the lattices is performed to evaluate their influence on the mechanical properties of the structure. Mechanical testing of Ti–6Al–4V lattices shows a compressive modulus ranging from 38.9 to 895.5 kPa in the flexible direction. In the other two directions, the lattices are designed to have minimal flexibility. Lattices embedded in a 1% agarose hydrogel show a strain‐rate‐dependent, viscoelastic behavior given by the hydrogel component with the additional stiffness of the titanium lattice. Stress distribution upon loading is simulated using finite element analysis (FEA) and compared to experimental data using multiple regression statistical analysis. As a proof of concept, an intervertebral spinal disc implant is designed with mechanical properties matching the compressive moduli of the nucleus pulposus and anulus fibrosus reported in the literature.