Shifeng Yu

Dr. Shifeng Yu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Shuyu WangShuyu Wang
Shuyu Wang
SZSun Zhaojia
Sun Zhaojia
SDshuaiyang duan
shuaiyang duan
YZYuliang Zhao
Yuliang Zhao
XSXiaopeng Sha
Xiaopeng Sha
LZLei Zuo
Lei Zuo
Soft robots made of hydrogels are suited for underwater exploration due to their biocompatibility and compliancy. Yet, reaching high dexterity and actuation force for hydrogel-based actuators is challenging. Meanwhile, real-time proprioception is critical for feedback control. Moreover, sensor integration to mimic living organisms remains problematic. To address these challenges, we introduce a hydrogel actuator driven by hydraulic force with a fast response (time constant 0.83 s). The highly stretchable and conductive hydrogel (1400% strain) is molded into the PneuNet shape, and two of them are further assembled symmetrically to actuate bi-directionally. Then, we demonstrate its bionic application for underwater swimming, showing 2 cm/s (0.19 BL/s) speed. Inspired by biological neuromuscular systems’ sensory motion, which unifies the sensing and actuation in a single unit, we explore the hydrogel actuator’s self-sensing capacity utilizing strain-induced resistance change. The results show that the soft actuator’s proprioception can monitor the undulation in real-time with a sensitivity of 0.2%/degree. Furthermore, we take a finite-element method and first-order differential equations to model the actuator’s bending in response to pressure. We show that such a model can precisely predict the robot’s bending response over a range of pressures. With the self-sensing actuator and the proposed model, we expect the new approach can lead to future soft robots for underwater exploration with feedback control, and the underlying mechanism of the undulation control might offer significant insights for biomimetic research.

16 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SYShifeng Yu
Shifeng Yu
Yongjia WuYongjia Wu
Yongjia Wu
Shuyu WangShuyu Wang
Shuyu Wang
MSMichael Siedler
Michael Siedler
PIPeter M. Ihnat
Peter M. Ihnat
LZLei Zuo
Lei Zuo
Calorimeters, which can be used for rapid thermal characterization of biomolecules, are getting intense attention in drug development. This paper presents a novel MEMS-based differential scanning calorimeter (DSC) for direct thermal characterization of protein samples. The DSC consisted of a pair of temperature sensors made by vanadium oxide (VOx) film with a temperature coefficient of resistivity of −0.025/K at 300 K, a microfluidic device with high thermal insulation (2.8 K/mW), and a Peltier heater for linear temperature scanning. The DSC exhibited high sensitivity (6.1 µV/µW), low noise (0.4 µW), high scanning rate (45 K/min), and low sample consumption volume (0.63 µL). The MEMS DSC was verified by measuring the temperature-induced denaturation of lysozyme at different pH, and then used to study the thermal stability of a monoclonal antibody (mAb), an antigen-binding fragment (Fab), and a dual variable domain immunoglobulin (DVD-Ig) at pH = 6. The results showed that lysozyme is a stable protein in the pH range of 4.0–8.0. The protein stability study revealed that the transition temperatures of the intact Fab fragment, mAb, and DVD proteins were comparable with conformational stability results obtained using conventional commercial DSC. These studies demonstrated that the MEMS DSC is an effective tool for directly understanding the thermal stability of antibodies in a high-throughput and low-cost manner compared to conventional calorimeters.

22 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
WDWenting Dai
Wenting Dai
Ziran WangZiran Wang
Ziran Wang
SYShifeng Yu
Shifeng Yu
KWKechun Wen
Kechun Wen
YYYucheng Yang
Yucheng Yang
QLQiao Lin
Qiao Lin
This paper presents the optimization of surface modification for aptameric graphene nanosensors for the measurement of biomarkers in undiluted physiological media. In these sensors, graphene transduces the binding between an aptamer and the intended target biomarker into a measurable signal while being coated with a polyethylene glycol (PEG) nanolayer to minimize nonspecific adsorption of matrix molecules. We perform a systematic study of the aptamer and PEG attachment schemes and parameters, including the impact of the serial or parallel PEG–aptamer attachment scheme, PEG molecular weight and surface density, and aptamer surface density on the sensor behavior, such as the responsivity to biomarker concentration changes, and importantly, they are used for operation in physiological media and have the ability to reject nonspecific binding to interfering molecules. We then use the understanding from this parametric study to identify graphene nanosensor designs that are optimally functionalized with PEG and aptamers to be strongly responsive to target biomarkers and effectively reduce nonspecific adsorption of interferents, thereby enabling sensitive and specific biomarker measurements in undiluted physiological media. The experimental results show that nanosensors that were optimized via serial modification with 5000 Da PEG at 15 mM and a 94 nt DNA aptamer at 500 nM allowed specific measurement of C-reactive protein (CRP) in undiluted human serum with a limit of detection (LOD) down to 27 pM, representing an up to 1000-fold improvement compared to previously reported CRP measurements.