Amy Roberts

Prof. Dr. Amy Roberts

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2016 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
AAA. J. Anderson
A. J. Anderson
TAT. Aramaki
T. Aramaki
MAM. Asai
M. Asai
WBW. Baker
W. Baker
SCSuperCDMS Collaboration
SuperCDMS Collaboration
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5  GeV/c2.

7 April 2017 in Physical Review D
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
AAA. J. Anderson
A. J. Anderson
TAT. Aramaki
T. Aramaki
IAI. Arnquist
I. Arnquist
WBW. Baker
W. Baker
SCSuperCDMS Collaboration
SuperCDMS Collaboration
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤10  GeV/c2) that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ∼1×10−43  cm2 for a dark matter particle mass of 1  GeV/c2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H3 and naturally occurring Si32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1  GeV/c2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5  GeV/c2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.

3 August 2018 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
TAT. Aralis
T. Aralis
TAT. Aramaki
T. Aramaki
IAI. J. Arnquist
I. J. Arnquist
EAE. Azadbakht
E. Azadbakht
XZX. Zhao
X. Zhao
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 g CDMS high-voltage device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1  MeV/c2. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 g d). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.

17 January 2018 in Physical Review D
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
AAA. J. Anderson
A. J. Anderson
TAT. Aralis
T. Aralis
TAT. Aramaki
T. Aramaki
IAI. J. Arnquist
I. J. Arnquist
SCSuperCDMS Collaboration
SuperCDMS Collaboration
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses <10  GeV/c2. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56  eVee (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ∼9  eVee at 0 keV to 101  eVee at ∼10  keVee. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10  GeV/c2. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses ≲3  GeV/c2.

1 May 2017 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
GAG. Agnolet
G. Agnolet
WBW. Baker
W. Baker
DBD. Barker
D. Barker
RBR. Beck
R. Beck
TCT.J. Carroll
T.J. Carroll
SYS.A. Yadavalli
S.A. Yadavalli

9 February 2018 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
TAT. Aramaki
T. Aramaki
IAI. J. Arnquist
I. J. Arnquist
WBW. Baker
W. Baker
DBD. Balakishiyeva
D. Balakishiyeva
SCSuperCDMS Collaboration
SuperCDMS Collaboration
We report the result of a blinded search for weakly interacting massive particles (WIMPs) using the majority of the SuperCDMS Soudan data set. With an exposure of 1690 kg d, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP–nucleon cross section of 1.4×10−44 (1.0×10−44)  cm2 at 46  GeV/c2. These results set the strongest limits for WIMP–germanium-nucleus interactions for masses >12  GeV/c2.