To compare the choroidal vascularity index (CVI) and choroidal thickness (CT) in smokers and healthy non-smoking subjects using spectral-domain optical coherence tomography (SD-OCT). Forty-two smok...
30 December 2022 in Indian Journal Of Ophthalmology
Purpose: To compare the anatomical, morphological, and functional outcomes of the conventional internal limiting membrane (ILM) peeling versus temporal inverted ILM flap technique for large full-thickness macular holes (FTMHs). Methods: Sixty eyes of 60 patients with a minimum base diameter >600 mm were included in this retrospective interventional study. Patients were divided into conventional ILM peeling (Group 1) and temporal inverted ILM flap (Group 2) groups. The hole closure rate, best-corrected visual acuity (BCVA), ellipsoid zone (EZ), and external limiting membrane (ELM) defects were analyzed at baseline and 6 months after surgery. Results: Hole closure was achieved in 24/32 (75.0%) cases of Group 1 and 27/28 (96.4%) cases of Group 2 (P = 0.029). The mean BCVA (logMAR) changed from 1.23 ± 0.47 to 0.70 ± 0.29 logMAR in Group 1 and from 1.03 ± 0.36 to 0.49 ± 0.24 logMAR in Group 2 at 6 months (P < 0.001 in both cases). U-shaped closure was observed in 5 (15.6%) eyes in Group 1 and 19 (67.9%) eyes in Group 2 (P < 0.001). The total restoration rates of ELM and EZ were significantly higher in the temporal inverted ILM flap group (P = 0.002, P = 0.001, respectively). Conclusion: The study results suggested that the FTMH closure rate, recovery of the outer retinal layers, and, consequently, the post-operative BCVA were better with the temporal inverted ILM flap technique than with the conventional ILM peeling for larger than 600 mm macular holes.
18 July 2021 in International Journal of Ophthalmology
AIM: To evaluate the atherogenic indices and the relationship with visual acuity and bilateral sequential involvement in patients with non-arteritic ischemic optic neuropathy (NAION). METHODS: A total of 65 patients with NAION and 48 age-sex matched healthy individuals were included in this retrospective study. The demographic characteristics and laboratory findings of the patients and control subjects were obtained from the electronic medical records. The atherogenic indices were calculated using the lipid parameters. The association between visual acuity, bilateral sequential involvement, and atherogenic indices was investigated. RESULTS: The mean age was 63.8±12.5y in the NAION group and 64.7±10.1y in control group (P=0.707). Although there were no significant differences in terms of total cholesterol (TC) and low-density lipoprotein cholesterol (LDL-c) between two groups (P=0.089, 0.091), all the non-traditional serum lipid ratios were significantly higher in NAION group (P20/200 (P=0.032, 0.025, 0.032, respectively). The values for the atherogenic indices were higher in NAION patients with bilateral sequential involvement in comparison to those with unilateral involvement (P=0.271, 0.127, 0.197, 0.128, 0.127, respectively). CONCLUSION: The study reveals a relationship between NAION and the non-traditional lipid ratios. Atherogenic indices may predict the visual loss severity and second eye involvement in patients with NAION.
7 February 2022 in European Journal of Ophthalmology
Purpose: To evaluate the acute effects of coffee on peripapillary and subfoveal choroidal structures using spectral-domain optical coherence tomography (SD-OCT). Materials and Methods: A total of 28 healthy individuals (study group) and 28 healthy controls were enrolled in this study. The peripapillary and subfoveal choroidal thickness (SFCT) was measured at baseline, 30 min, 1 h, 2 h, and 4 h, following coffee (75 mg caffeine/200 ml) intake in the study group and the same amount of water in the control group. Choroidal images were binarized to the luminal area (LA), stromal area (SA), and total choroidal area (TCA) using ImageJ software. Similar to the CT, the peripapillary and subfoveal choroidal vascularity indices (CVIs) were calculated at the same time points in both groups. Results: CT and CVI measurements of four peripapillary quadrants displayed no significant difference at baseline and all-time points in both groups ( p > 0.05). In the study group, SFCT was found to be significantly lower (at 30 min, 1 h, 2 h, and 4 h) than the baseline measurement ( p < 0.05). Additionally, subfoveal LA, TCA, and CVI decreased in all-time points compared with baseline measurements ( p < 0.05, for all). This was not true for the subfoveal SA ( p > 0.05). No significant difference was found between the respective SFCT and subfoveal CVI measurements in the control group ( p > 0.05, for all). Conclusion: Our study revealed that peripapillary choroidal thickness and CVI did not change following a cup of coffee intake, while subfoveal CT, LA, TCA, and CVI significantly decreased for at least 4 h.