Energy efficiency, advanced controls and renewable energy systems for operating industrial, residentialand tertiary sector buildings designed to be Near-Zero Energy are investigated to explore the perfor-mance gap. The analysis involves a comparison of energy dynamic and quasi-dynamic models with datafrom smart monitoring systems, indoor and outdoor environment measurements, power consumptionand production data. Specific issues and conclusions have been drawn as the basis for addressing the per-formance gap between energy efficiency prediction in the design phase and measurements’ evaluationin operational phase
Demand response offers the possibility of altering the profile of power consumption of individual buildings or building districts, i.e., microgrids, for economic return. There is significant potential of demand response in enabling flexibility via advanced grid management options, allowing higher renewable energy penetration and efficient exploitation of resources. Demand response and distributed energy resource dynamic management are gradually gaining importance as valuable assets for managing peak loads, grid balance, renewable energy source intermittency, and energy losses. In this paper, the potential for operational optimization of a heating, ventilation, and air conditioning (HVAC) system in a smart near-zero-energy industrial building is investigated with the aid of a genetic algorithm. The analysis involves a validated building energy model, a model of energy cost, and an optimization model for establishing HVAC optimum temperature set points. Optimization aims at establishing the trade-off between the minimum daily cost of energy and thermal comfort. Predicted mean vote is integrated in the objective function to ensure thermal comfort requirements are met.
Demand Response (DR) is a fundamental aspect of the smart grid concept, as it refers to the necessary open and transparent market framework linking energy costs to the actual grid operations. DR allows consumers to directly or indirectly participate in the markets where energy is being exchanged. One of the main challenges for engaging in DR is associated with the initial assessment of the potential rewards and risks under a given pricing scheme. In this paper, a Genetic Algorithm (GA) optimisation model, using Artificial Neural Network (ANN) power predictions for day-ahead energy management at the building and district levels, is proposed. Individual building and building group analysis is conducted to evaluate ANN predictions and GA-generated solutions. ANN-based short term electric power forecasting is exploited in predicting day-ahead demand, and form a baseline scenario. GA optimisation is conducted to provide balanced load shifting and cost-of-energy solutions based on two alternate pricing schemes. Results demonstrate the effectiveness of this approach for assessing DR load shifting options based on a Time of Use pricing scheme. Through the analysis of the results, the practical benefits and limitations of the proposed approach are addressed.
The operation of buildings is linked to approximately 36% of the global energy consumption, 40% of greenhouse gas emissions, and climate change. Assessing the energy consumption and efficiency of buildings is a complex task addressed by a variety of methods. Building energy modeling is among the dominant methodologies in evaluating the energy efficiency of buildings commonly applied for evaluating design and renovation energy efficiency measures. Although building energy modeling is a valuable tool, it is rarely the case that simulation results are assessed against the building’s actual energy performance. In this context, the simulation results of the HVAC energy consumption in the case of a smart industrial near-zero energy building are used to explore areas of uncertainty and deviation of the building energy model against measured data. Initial model results are improved based on a trial and error approach to minimize deviation based on key identified parameters. In addition, a novel approach based on functional shape modeling and Kalman filtering is developed and applied to further minimize systematic discrepancies. Results indicate a significant initial performance gap between the initial model and the actual energy consumption. The efficiency and the effectiveness of the developed integrated model is highlighted.