Caixia Gao

Prof. Dr. Caixia Gao

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HCHao Chen
Hao Chen
CGCaixia Gao
Caixia Gao
JSJiKai Si
JiKai Si
YNYanjie Nie
Yanjie Nie
Yihua HuYihua Hu
Yihua Hu
Demagnetization fault in a permanent magnet synchronous motor (PMSM) degrades its performance and may cause serious catastrophes. Fault localization technique can improve the reliability and safety of PMSM and provide important information for developing operation and maintenance strategies. Thus, a fault localization method is so important. Mainstream is a common method that uses search coil installed on every stator tooth to diagnose fault location. Due to the use of a large number of search coils, the method is limited in terms of invasiveness, implementation cost, and installation. Moreover, the method can only diagnose the fault location in PMSM with one demagnetized permanent magnet (PM). This article proposes a novel method which can detect the specific location of demagnetized PMs in PMSM with any types of demagnetization faults. The method only needs three additional toroidal yoke coils wound around the stator yoke. Toroidal yoke coils are used to measure the back electromotive force (EMF). The demagnetization fault localization signals (DFLSs) are produced by basic calculation of the output signals of three search coils. The DFLSs are partitioned according to the electrical period. The location of demagnetization fault can be diagnosed through analyzing each electric period waveform of DFLSs. First, the arrangement of toroidal-yoke-type search coil and the construction method of DFLSs are introduced. Second, a partitioned analytical model of DFLSs is developed. Third, waveforms in one electric period of DFLSs under preset fault types are investigated. Finally, the method for diagnosing demagnetization fault in PMSM is proposed. The simulation and experimental results justify the precision of the proposed search coil which shows the maximum error of back EMF to be 4.1%. It also shows the ability of the method to locate demagnetized PMs when the demagnetization severity (the ratio of the change in coercive force of PM to the normal coercive force) is 10%. This study provides a new method for diagnosing demagnetization fault, as well as provides a significant reference for fault post-processing and fault-tolerant control of PMSM.

24 August 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
CGCaixia Gao
Caixia Gao
BLBingkun Li
Bingkun Li
HCHao Chen
Hao Chen
YXYaohui Xu
Yaohui Xu
XXXiaozhuo Xu
Xiaozhuo Xu
Yihua HuYihua Hu
Yihua Hu
This paper presents a less-invasive method for accurately diagnosing of demagnetization fault in permanent magnet synchronous motors (PMSM) using rotor partition. The rotor PMs are partitioned according to certain rules. The PMs condition of each partition is sequentially diagnosed through the signals measured by two additional toroidal yoke coils, thus the conditions of all rotor PMs are diagnosed. Firstly, the working mechanism of the search coil is analyzed, and the partitioned model of SC residual voltage is also presented. Secondly, the relationship between residual voltage signatures of SC and different demagnetization fault modes is studied by the established model. From the analysis, a demagnetization fault location method is proposed. The simulation and experiment results validate the correctness of the proposed method and indicate the proposed fault location method applies to the online diagnosis of both local and uniform demagnetization faults. In addition, the location of demagnetized PMs can be detected under any demagnetization fault condition and is not affected by other fault signals. Lastly, a comparison with existing methods based on search coil is performed and indicates the proposed method can locate faults more quickly and accurately than that of existing methods when the PM is demagnetized by 10%, and it is less invasive, especially has advantages in locating demagnetization PMs in PMSM with numerous pole-pairs. This article provides a new idea for demagnetization fault location of PMSM, as well as provides a significant reference for a motor maintenance schedule and fault-tolerant control of PMSM.

1 July 2020 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
KLKe Lv
Ke Lv
CGCaixia Gao
Caixia Gao
JSJikai Si
Jikai Si
HFHaichao Feng
Haichao Feng
WCWenping Cao
Wenping Cao
Inter‐turn short‐circuit fault (ISF) degrades its reliability and may cause serious catastrophes for direct‐drive permanent magnet synchronous motor (DDPMSM). Fault location technology can reduce maintenance time, increase the mean time between failure (MTBF), and then improve the reliability of DDPMSM. Hence, an intelligent fault locating system for DDPMSM is proposed in this paper. This system proposes a knowledge graph (KG) based diagnostic tool for detection and location of the fault coil. First, the fault model of the DDPMSM with multiple branches parallel winding is established, which is used to analyze the fault characteristics of motor. Second, the BDC and BRC are proposed as the fault indicator. The effectiveness and robustness of fault indicator are analyzed. Then, the KG system are designed and established according to the relationship between fault indicator and location of fault coil. Finally, the system is tested by data under different fault and operation conditions. The test results showed that the proposed fault locating system can detect and locate the fault coil in early stage. The minimum ratio of shorted turns to branch turns that can be detected is 0.52%. The minimum ratio of shorted turns to branch turns that can be located is 6.25%.

29 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
CGCaixia Gao
Caixia Gao
MGMengzhen Gao
Mengzhen Gao
JSJiKai Si
JiKai Si
Yihua HuYihua Hu
Yihua Hu
CGChun Gan
Chun Gan
A direct-drive motor has the merits of low speed, high torque, and elimination of mechanical deceleration mechanisms, and is widely used in various fields. A novel direct-drive permanent magnet synchronous motor is presented herein, in which all coils are wrapped around the stator yoke in the same orientation. The structure of the novel direct-drive permanent magnet synchronous motor with toroidal windings (N-TWDDPMSM) is introduced and its operating principle is analyzed by describing the variation in the armature magnet field versus time. Furthermore, based on the same power grade and mechanical size, several finite-element models of motors with different windings are established using Magnet software to analyze the distribution of magnetic field, back-electromotive force (back-EMF), power-angle characteristics, loss characteristics, etc. Compared with the traditional permanent magnet synchronous motor (T-PMSM), the traditional permanent magnet synchronous motor with toroidal windings (T-TWPMSM), and the N-TWDDPMSM, the N-TWDDPMSM shows advantages of low speed and high torque, and the feasibility and superiority of the N-TWDDPMSM are verified.

28 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CGCaixia Gao
Caixia Gao
BGBo Gao
Bo Gao
XXXiaozhuo Xu
Xiaozhuo Xu
JSJiKai Si
JiKai Si
Yihua HuYihua Hu
Yihua Hu
Demagnetization fault in a direct-drive permanent magnet synchronous motor (DDPMSM) degrades its energy efficiency and performance, and even causes unscheduled downtime. To shorten the fault recovery time of demagnetization fault, reduce motor maintenance costs, and develop a fault-tolerant strategy, it is necessary to study early and automatic fault detection and location technology. However, the current fault location methods either fail to locate arbitrary demagnetization faults or require a large number of search coils. These methods have not yet studied the automatic location of faults. In this article, a method based on knowledge graph (KG) is proposed to automatically locate demagnetization faults in arbitrary demagnetization conditions. First, three toroidal-yoke-type search coils are installed on stator slots, and three fault location signals (FLSs) are constructed based on the back electromotive force of search coils. The FLSs under different demagnetization fault types are investigated. Second, two fault indicators are extracted from the FLSs and used as input to the KG. The correspondence between fault indicators and demagnetization fault types is established. Simulation results show that the proposed indicators have good robustness to the operating conditions and motor design. Third, a KG system is established according to the constructed relationship. The system is tested by a database derived from experiments and finite element models. Test results demonstrate that the proposed method can automatically locate demagnetization fault with a minimum detectable severity of 10% for each faulty permanent magnet. Finally, experiments are conducted to verify the correctness and effectiveness of the proposed method.

12 February 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
CGCaixia Gao
Caixia Gao
KLKe Lv
Ke Lv
JSJiKai Si
JiKai Si
HFHaichao Feng
Haichao Feng
YHYihua Hu
Yihua Hu
In this article, the effects produced by interturn short-circuit faults (ISFs) on variables of the direct-drive permanent magnet synchronous motors (DDPMSMs) are investigated. A finite-element method model is established to calculate the motor variables of DDPMSM that includes average torque, second-harmonic torque, torque ripple, branch differential current, branch residual current, branch voltage, and so on. Then, the motor variables under different cases, including various fault conditions and various operating conditions, are analyzed to understand the effects of ISF. Besides, the fault indicators (FIs) are selected based on the analysis of ISF. Finally, the simulation and experimental results are compared at different fault conditions and operating conditions to fully verify the analysis of ISF and FIs. This work provides a significant reference for the fault diagnosis, fault postprocessing, and fault-tolerant control of DDPMSM.