Silas Leavesley

Dr. Silas Leavesley

University of South Alabama, Mobile, Alabama, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2011 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
SLSilas Leavesley
Silas Leavesley
NANaga Annamdevula
Naga Annamdevula
JBJohn Boni
John Boni
SSSamantha Stocker
Samantha Stocker
KGKristin Grant
Kristin Grant
DADiego Alvarez
Diego Alvarez

21 April 2016 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
SLSilas Leavesley
Silas Leavesley
TRThomas C. Rich
Thomas C. Rich
Click on the article title to read more.

15 March 2012 in American Journal of Physiology-Cell Physiology
Verified
Journal Article
Closed access
PDF file
WFWei P. Feinstein
Wei P. Feinstein
BZBing Zhu
Bing Zhu
SLSilas Leavesley
Silas Leavesley
SSSarah L. Sayner
Sarah L. Sayner
TRThomas C. Rich
Thomas C. Rich
Cyclic AMP signals encode information required to differentially regulate a wide variety of cellular responses; yet it is not well understood how information is encrypted within these signals. An emerging concept is that compartmentalization underlies specificity within the cAMP signaling pathway. This concept is based on a series of observations indicating that cAMP levels are distinct in different regions of the cell. One such observation is that cAMP production at the plasma membrane increases pulmonary microvascular endothelial barrier integrity, whereas cAMP production in the cytosol disrupts barrier integrity. To better understand how cAMP signals might be compartmentalized, we have developed mathematical models in which cellular geometry as well as total adenylyl cyclase and phosphodiesterase activities were constrained to approximate values measured in pulmonary microvascular endothelial cells. These simulations suggest that the subcellular localizations of adenylyl cyclase and phosphodiesterase activities are by themselves insufficient to generate physiologically relevant cAMP gradients. Thus, the assembly of adenylyl cyclase, phosphodiesterase, and protein kinase A onto protein scaffolds is by itself unlikely to ensure signal specificity. Rather, our simulations suggest that reductions in the effective cAMP diffusion coefficient may facilitate the formation of substantial cAMP gradients. We conclude that reductions in the effective rate of cAMP diffusion due to buffers, structural impediments, and local changes in viscosity greatly facilitate the ability of signaling complexes to impart specificity within the cAMP signaling pathway.

1 October 2016 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
SLSilas Leavesley
Silas Leavesley
MWMikayla Walters
Mikayla Walters
CLCarmen Lopez
Carmen Lopez
TBThomas Baker
Thomas Baker
PFPeter F. Favreau
Peter F. Favreau
CBCarole W. Boudreaux
Carole W. Boudreaux
Optical spectroscopy and hyperspectral imaging have shown the potential to discriminate between cancerous and noncancerous tissue with high sensitivity and specificity. However, to date, these techniques have not been effectively translated to real-time endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents new technology that may be well suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The goal of this study was to evaluate the initial feasibility of using fluorescence excitation-scanning hyperspectral imaging for measuring changes in fluorescence excitation spectrum concurrent with colonic adenocarcinoma using a small pre-pilot-scale sample size. Ex vivo analysis was performed using resected pairs of colorectal adenocarcinoma and normal mucosa. Adenocarcinoma was confirmed by histologic evaluation of hematoxylin and eosin (H&E) permanent sections. Specimens were imaged using a custom hyperspectral imaging fluorescence excitation-scanning microscope system. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation range of 390 to 450 nm that could be the basis for wavelength-dependent detection of colorectal cancers. Hence, excitation-scanning hyperspectral imaging may offer an alternative approach for discriminating adenocarcinoma from surrounding normal colonic mucosa, but further studies will be required to evaluate the accuracy of this approach using a larger patient cohort.

1 April 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PFPeter F. Favreau
Peter F. Favreau
CHClarissa Hernandez
Clarissa Hernandez
THTiffany Heaster
Tiffany Heaster
DADiego Alvarez
Diego Alvarez
TRThomas C. Rich
Thomas C. Rich
SLSilas Leavesley
Silas Leavesley
Hyperspectral imaging is a versatile tool that has recently been applied to a variety of biomedical applications, notably live-cell and whole-tissue signaling. Traditional hyperspectral imaging approaches filter the fluorescence emission over a broad wavelength range while exciting at a single band. However, these emission-scanning approaches have shown reduced sensitivity due to light attenuation from spectral filtering. Consequently, emission scanning has limited applicability for time-sensitive studies and photosensitive applications. In this work, we have developed an excitation-scanning hyperspectral imaging microscope that overcomes these limitations by providing high transmission with short acquisition times. This is achieved by filtering the fluorescence excitation rather than the emission. We tested the efficacy of the excitation-scanning microscope in a side-by-side comparison with emission scanning for detection of green fluorescent protein (GFP)-expressing endothelial cells in highly autofluorescent lung tissue. Excitation scanning provided higher signal-to-noise characteristics, as well as shorter acquisition times (300  ms/wavelength band with excitation scanning versus 3  s/wavelength band with emission scanning). Excitation scanning also provided higher delineation of nuclear and cell borders, and increased identification of GFP regions in highly autofluorescent tissue. These results demonstrate excitation scanning has utility in a wide range of time-dependent and photosensitive applications.

8 August 2013 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
SLSilas Leavesley
Silas Leavesley
ABAndrea L. Britain
Andrea L. Britain
LCLauren K. Cichon
Lauren K. Cichon
VNViacheslav O. Nikolaev
Viacheslav O. Nikolaev
TRThomas C. Rich
Thomas C. Rich
Förster resonance energy transfer (FRET) techniques have proven invaluable for probing the complex nature of protein–protein interactions, protein folding, and intracellular signaling events. These techniques have traditionally been implemented with the use of one or more fluorescence band‐pass filters, either as fluorescence microscopy filter cubes, or as dichroic mirrors and band‐pass filters in flow cytometry. In addition, new approaches for measuring FRET, such as fluorescence lifetime and acceptor photobleaching, have been developed. Hyperspectral techniques for imaging and flow cytometry have also shown to be promising for performing FRET measurements. In this study, we have compared traditional (filter‐based) FRET approaches to three spectral‐based approaches: the ratio of acceptor‐to‐donor peak emission, linear spectral unmixing, and linear spectral unmixing with a correction for direct acceptor excitation. All methods are estimates of FRET efficiency, except for one‐filter set and three‐filter set FRET indices, which are included for consistency with prior literature. In the first part of this study, spectrofluorimetric data were collected from a CFP–Epac–YFP FRET probe that has been used for intracellular cAMP measurements. All comparisons were performed using the same spectrofluorimetric datasets as input data, to provide a relevant comparison. Linear spectral unmixing resulted in measurements with the lowest coefficient of variation (0.10) as well as accurate fits using the Hill equation. FRET efficiency methods produced coefficients of variation of less than 0.20, while FRET indices produced coefficients of variation greater than 8.00. These results demonstrate that spectral FRET measurements provide improved response over standard, filter‐based measurements. Using spectral approaches, single‐cell measurements were conducted through hyperspectral confocal microscopy, linear unmixing, and cell segmentation with quantitative image analysis. Results from these studies confirmed that spectral imaging is effective for measuring subcellular, time‐dependent FRET dynamics and that additional fluorescent signals can be readily separated from FRET signals, enabling multilabel studies of molecular interactions. © 2013 International Society for Advancement of Cytometry