Purpose: Quantitative metrics should be used as a risk management option whenever possible. This work proposes a framework for the risk quantification and the resulting risk-based design of control charts to monitor quality control points.Design/methodology/approach: Two quality control models were considered for the risk quantification analysis. Estimated operating characteristic curves, expressing the defect rate (on a ppm basis) as a function of the sample size, process disturbance magnitude and process capacity, were devised to evaluate the maximum rate of defective product of the processes. The proposed framework applicability on monitoring critical control points in Hazard Analysis and Critical Control Point (HACCP) systems was further evaluated by Monte Carlo simulations.Findings: Results demonstrate that the proposed monitoring systems can be tuned to achieve an admissible failure risk, conveniently expressed as the number of non-conforming items produced per million products, and these risks can be properly communicated. This risk-based approach can be used to validate critical control point monitoring procedures in HACCP plans. The expected rates of non-conforming items sent out to clients estimated through stochastic simulation procedures agree well with theoretical predictions.Practical implications: The procedures outlined in this study may be used to establish the statistical validity of monitoring systems that uses control charts. The intrinsic risks of these control systems can be assessed and communicated properly in order to demonstrate the effectiveness of quality control procedures to auditing third parties.Originality/value: This study provides advancements toward practical directives for the implementation of statistical process control in the food industry. The proposed framework allows the assessment and communication of intrinsic failure risks of quality monitoring systems. It may contribute to the establishment of risk-based thinking in the constitution of quality management systems.
17 November 2023 in Journal of Medical Engineering & Technology
Climate change has amplified the importance of continuous and precise body core temperature (Tcore) monitoring in the everyday life. In this context, assessing Tcore through ingestible capsules technology, i.e., gastrointestinal temperature (Tgastrointestinal), emerges as a good alternative to prevent heat-related illness. Therefore, we conducted a systematic review to point out values of normal Tgastrointestinal measured through ingestible capsules in healthy humans. The study followed PRISMA guidelines and searched the PubMed and Scielo databases from 1971 to 2023. Our search strategy included the descriptors ("gastrointestinal temperature") AND ("measurement"), and eligible studies had to be written in English and measured Tgastrointestinal using ingestible capsules or sensors in healthy adults aged 18-59 at rest. Two pairs of researchers independently reviewed titles and abstracts and identified 35 relevant articles out of 1,088 in the initial search. An average value of 37.13 °C with a standard deviation of 0.24 °C was observed, independently of the gender. The values measured ranged from 36.70 °C to 37.69 °C. In conclusion, this systematic review pointed out the mean value of 37.13 ± 0.24 °C measured by ingestible capsules as reference for resting Tgastrointestinal in healthy adult individuals.
This study assessed the accuracy of the EXERGEN TAT-5000 temporal scanner (TEXERGEN) (EXERGEN, Watertown, MA, USA) for estimating core body temperature (TCORE) during rest, progressive cycling exercise, and post-exercise recovery in a hot environment. Fourteen healthy adults (7 men and 7 women) completed a laboratory protocol consisting of 10 min of rest, 60 min of cycling, and 25 min of recovery at an ambient temperature of 32 °C and a relative humidity of 60%. Gastrointestinal temperature (TGi), measured via telemetry capsules, served as the criterion method. A total of 5376 paired measurements were analyzed. Throughout the protocol, TEXERGEN systematically underestimated TCORE compared with TGi, with mean biases between −0.35 °C and −1.15 °C. The overall 95% confidence intervals ranged from ±0.91 to ±1.43 °C, demonstrating poor precision. Limits of agreement were wide (from −2.00 to 0.87 °C), and concordance correlation coefficients (CCC) indicated poor agreement (CCC < 0.90 in all conditions). The underestimation was more pronounced during exercise and recovery, when TCORE remained high according to TGi but decreased according to TEXERGEN. These results indicate that TEXERGEN does not monitor TCORE accurately under heat stress or during rapid metabolic changes. Therefore, the use of this device is not recommended during and after exercises under environmental heat stress.