Hengxuan Zhao

Mr. Hengxuan Zhao


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2024 in Fire
Verified
Journal Article
Open access
PDF file
QDQiwei Dong
Qiwei Dong
LJLi Junmei
Li Junmei
Yanfeng LiYanfeng Li
Yanfeng Li
HLHuimin Lu
Huimin Lu
HZHengxuan Zhao
Hengxuan Zhao
The smoke diffusion characteristics in an asymmetric V-shaped tunnel located at the slope change point were studied by experiments in a 1/20 small-scale tunnel. The influences of the slope composition of the V-shaped tunnel and fire heat release rate (fire HRR) on the fire-induced airflow velocity in the tunnel and maximum ceiling temperature rise were the focuses. The results show that due to the height difference between the two ports of the asymmetric tunnel, the resulting thermal pressure difference between the two sides of the tunnel drives the smoke to flow toward the large slope side and the inlet-induced airflow velocity increases with the increases in the slope difference and the HRR. The dimensionless inlet-induced airflow velocity v* is proportional to φ10.525H*0.634φ1−0.223Q*0.288. The maximum ceiling temperature rise increases with the increase in the HRR and decreases with the slope differences between the two side tunnels. An empirical model of the dimensionless induced airflow speed and the maximum temperature rise was proposed.

21 April 2025 in Fire
Verified
Journal Article
Open access
PDF file
YQYuzhou Qie
Yuzhou Qie
LJLi Junmei
Li Junmei
Yanfeng LiYanfeng Li
Yanfeng Li
HZHengxuan Zhao
Hengxuan Zhao
XLXiushan Lin
Xiushan Lin
ZWZheng Wang
Zheng Wang
Small-scale model experiments were conducted to examine the effectiveness of a point smoke exhaust system in an asymmetrical V-shaped tunnel. Using a design fire power of 20 MW as a reference, the study explored the optimal smoke exhaust rate for the point exhaust system in tunnels. Additionally, the impact of different slope combinations and various smoke vent opening configurations on the smoke control efficiency was analyzed when the fire source was positioned at the slope transition point of the V-shaped tunnel. The results indicate that an exhaust rate of approximately 140–160 m3/s is effective in controlling smoke for a 20 MW fire. In V-shaped tunnels, when three exhaust vents are symmetrically opened on both sides of the fire source, smoke diffusion on the large slope side remains uncontrolled. To address this issue, increasing the number of smoke exhaust vents on the large slope side can enhance smoke control. However, when the slope difference between the two sides of an asymmetrical V-shaped tunnel is excessively large—especially when the large side has a very high inclination—effective smoke control becomes significantly more challenging.

23 December 2025 in Fire
Verified
Journal Article
Open access
PDF file
LJLi Junmei
Li Junmei
HZHengxuan Zhao
Hengxuan Zhao
WLWenbo Liu
Wenbo Liu
Yanfeng LiYanfeng Li
Yanfeng Li
Asymmetric V-shaped tunnels are commonly found in newly built urban underground road tunnels. In such kinds of tunnels, the flow of smoke becomes very complicated in the event of a fire, and effective smoke control under longitudinal ventilation is challenging. The critical ventilation speed under different slope combinations and heat release rates (HRRs) of fire in asymmetric V-shaped tunnels with the fire sources located at the slope change point were investigated by experiments through a 1:20 small-scale V-shaped model tunnel. The research results indicate that the critical ventilation speed increases with the increasing of fire HRR. If the fire source power remains constant, when longitudinal ventilation is implemented on the side with small slope, the critical ventilation speed decreases as the slope difference between the two sides of the slope change point increases. Conversely, when longitudinal ventilation is implemented from the large slope side, the critical ventilation speed increases as the slope difference increases. For practical engineering applications, based on the critical ventilation speed of single-slope tunnels, and incorporating the experimental results from model tests, calculation models for the critical ventilation velocity were developed, respectively, for longitudinal ventilation implemented from large or small slope sides with slope corrections taken into account. The research findings can provide technical support for effective smoke control in V-shaped tunnels during fire incidents.

2 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
LJLi Junmei
Li Junmei
HZHengxuan Zhao
Hengxuan Zhao
WLWenbo Liu
Wenbo Liu
Yanfeng LiYanfeng Li
Yanfeng Li
Asymmetric V-shaped tunnels are commonly found in newly built urban underground road tunnels. During a fire, the smoke flow in such kind of tunnels is complex, and effective smoke control under longitudinal ventilation is challenging. The critical ventilation speed under different slope combinations and fire heat release rate (HRR) in asymmetric V-shaped tunnel with the fire source located at the slope change point were studied by experiments through a 1:20 scaled model tunnel. The research results indicate that the critical ventilation speed increases with the increase of the fire HRR. Under the same fire heat release rate, when longitudinal ventilation is implemented on the side with small slope, the critical ventilation speed decreases as the slope difference between the two sides of the slope change point increases. Conversely, when longitudinal ventilation is implemented from the large slope side, the critical ventilation speed increases with the slope difference increasing. For practical engineering applications, based on the critical ventilation speed of the single-slope tunnel, combining with the experimental results, slope corrections were applied to the critical ventilation velocity of V-shaped tunnels. Calculation models for the critical ventilation velocity under longitudinal ventilation from the large or small slope sides were obtained respectively. The research findings can provide technical support for the design and operation of smoke control systems in V-shaped tunnels during fire incidents.