Martin Bleichner

Dr. Martin Bleichner


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2015 in Scientific Reports
Verified
Journal Article
Open access
SDStefan Debener
Stefan Debener
REReiner Emkes
Reiner Emkes
MVMaarten De Vos
Maarten De Vos
MBMartin Bleichner
Martin Bleichner
This study presents first evidence that reliable EEG data can be recorded with a new cEEGrid electrode array, which consists of ten electrodes printed on flexible sheet and arranged in a c-shape to fit around the ear. Ten participants wore two cEEGrid systems for at least seven hours. Using a smartphone for stimulus delivery and signal acquisition, resting EEG and auditory oddball data were collected in the morning and in the afternoon six to seven hours apart. Analysis of resting EEG data confirmed well-known spectral differences between eyes open and eyes closed conditions. The ERP results confirmed the predicted condition effects with significantly larger P300 amplitudes for target compared to standard tones and a high test-retest reliability of the P300 amplitude (r > = .74). Moreover, a linear classifier trained on data from the morning session revealed similar performance in classification accuracy for the morning and the afternoon sessions (both > 70%). These findings demonstrate the feasibility of concealed and comfortable brain activity acquisition over many hours.

7 April 2017 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
MBMartin Bleichner
Martin Bleichner
SDStefan Debener
Stefan Debener
Electroencephalography (EEG) is an important clinical tool and frequently used to study the brain-behavior relationship in humans noninvasively. Traditionally, EEG signals are recorded by distributing electrodes on the scalp and keeping them in place with glue, rubber bands, or elastic caps. This setup provides good coverage of the head, but is impractical for EEG acquisition in natural daily-life situations. Here we propose the transparent EEG concept. Transparent EEG aims for motion tolerant, highly portable, unobtrusive and near invisible data acquisition with minimum disturbance of a user’s daily activities. In recent years several ear-centered EEG solutions that are compatible with the transparent EEG concept have been presented. We discuss work showing that miniature electrodes placed in and around the human ear are a feasible solution, as they are sensitive to pick up electrical signals stemming from various brain and non-brain sources. We also describe the cEEGrid flex-printed sensor array, which enables unobtrusive multi-channel EEG acquisition from around the ear. In a number of validation studies we found that the cEEGrid enables the recording of meaningful continuous EEG, event-related potentials and neural oscillations. Here we explain the rationale underlying the cEEGrid ear-EEG solution, present possible use cases and identify and open issues that need to be solved on the way towards transparent EEG.

1 July 2015 in NeuroImage
Verified
Journal Article
Closed access
CZCatharina Zich
Catharina Zich
SDStefan Debener
Stefan Debener
CKCornelia Kranczioch
Cornelia Kranczioch
MBMartin Bleichner
Martin Bleichner
IGIngmar Gutberlet
Ingmar Gutberlet
MVMaarten De Vos
Maarten De Vos

27 July 2016 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
BMBojana Mirkovic
Bojana Mirkovic
MBMartin Bleichner
Martin Bleichner
MVMaarten De Vos
Maarten De Vos
SDStefan Debener
Stefan Debener
Target speaker identification is essential for speech enhancement algorithms in assistive devices aimed towards helping the hearing impaired. Several recent studies have reported that target speaker identification is possible through electroencephalography (EEG) recordings. If the EEG system could be reduced to acceptable size while retaining the signal quality, hearing aids could benefit from the integration with concealed EEG. To compare the performance of a multichannel around-the-ear EEG system with high-density cap EEG recordings an envelope tracking algorithm was applied in a competitive speaker paradigm. The data from 20 normal hearing listeners were concurrently collected from the traditional state-of-the-art laboratory wired EEG system and a wireless mobile EEG system with two bilaterally-placed around-the-ear electrode arrays (cEEGrids). The results show that the cEEGrid ear-EEG technology captured neural signals that allowed the identification of the attended speaker above chance-level, with 69.3% accuracy, while cap-EEG signals resulted in the accuracy of 84.8%. Further analyses investigated the influence of ear-EEG signal quality and revealed that the envelope tracking procedure was unaffected by variability in channel impedances. We conclude that the quality of concealed ear-EEG recordings as acquired with the cEEGrid array has potential to be used in the brain-computer interface steering of hearing aids.

5 October 2016 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
MBMartin Bleichner
Martin Bleichner
BMBojana Mirkovic
Bojana Mirkovic
SDStefan Debener
Stefan Debener
This study presents a direct comparison of a classical EEG cap setup with a new around-the-ear electrode array (cEEGrid) to gain a better understanding of the potential of ear-centered EEG. Concurrent EEG was recorded from a classical scalp EEG cap and two cEEGrids that were placed around the left and the right ear. Twenty participants performed a spatial auditory attention task in which three sound streams were presented simultaneously. The sound streams were three seconds long and differed in the direction of origin (front, left, right) and the number of beats (3, 4, 5 respectively), as well as the timbre and pitch. The participants had to attend to either the left or the right sound stream. We found clear attention modulated ERP effects reflecting the attended sound stream for both electrode setups, which agreed in morphology and effect size. A single-trial template matching classification showed that the direction of attention could be decoded significantly above chance (50%) for at least 16 out of 20 participants for both systems. The comparably high classification results of the single trial analysis underline the quality of the signal recorded with the cEEGrids. These findings are further evidence for the feasibility of around the-ear EEG recordings and demonstrate that well described ERPs can be measured. We conclude that concealed behind-the-ear EEG recordings can be an alternative to classical cap EEG acquisition for auditory attention monitoring.

8 May 2018 in Frontiers in Neuroscience
Verified
Journal Article
Open access
MSMaren Stropahl
Maren Stropahl
ABAnna-Katharina R. Bauer
Anna-Katharina R. Bauer
SDStefan Debener
Stefan Debener
MBMartin Bleichner
Martin Bleichner
EEG source localization approaches are often used to disentangle the spatial patterns mixed up in scalp electroencephalography (EEG) recordings. However, approaches differ substantially between experiments, may be strongly parameter-dependent, and results are not necessarily meaningful. In this paper we provide a pipeline for EEG source estimation, from raw EEG data pre-processing using EEGLAB functions up to source-level analysis as implemented in Brainstorm. The pipeline is tested using a data set of 10 individuals performing an auditory attention task. The analysis approach estimates sources of 64-channel EEG data without the prerequisite of individual anatomies or individually digitized sensor positions. First, we show advanced EEG pre-processing using EEGLAB, which includes artefact attenuation using independent component analysis (ICA). ICA is a linear decomposition technique that aims to reveal the underlying statistical sources of mixed signals and is further a powerful tool to attenuate stereotypical artefacts (e.g. eye movements or heartbeat). Data submitted to ICA are pre-processed to facilitate good-quality decompositions. Aiming towards an objective approach on component identification, the semi-automatic CORRMAP algorithm is applied for the identification of components representing prominent and stereotypic artefacts. Second, we present a step-wise approach to estimate active sources of auditory cortex event-related processing, on a single subject level. The presented approach assumes that no individual anatomy is available and therefore the default anatomy ICBM152, as implemented in Brainstorm, is used for all individuals. Individual noise modelling in this dataset is based on the pre-stimulus baseline period. For EEG source modelling we use the OpenMEEG algorithm as the underlying forward model based on the symmetric Boundary Element Method (BEM). We then apply the method of dynamical statistical parametric mapping (dSPM) to obtain physiologically plausible EEG source estimates. Finally, we show how to perform group level analysis in the time domain on anatomically defined regions of interest (auditory scout). The proposed pipeline needs to be tailored to the specific datasets and paradigms. However, the straightforward combination of EEGLAB and Brainstorm analysis tools may be of interest to others performing EEG source localization.