Ritul Kamal

Dr. Ritul Kamal

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2017 in Environmental Health
Verified
Journal Article
Open access
PDF file
ASAmarnath Singh
Amarnath Singh
CKChandrasekharan Nair Kesavachandran
Chandrasekharan Nair Kesavachandran
RKRitul Kamal
Ritul Kamal
VBVipin Bihari
Vipin Bihari
Afzal AnsariAfzal Ansari
Afzal Ansari
AKAltaf Hussain Khan
Altaf Hussain Khan
The present study is an attempt to explore the association between kitchen indoor air pollutants and physiological profiles in kitchen workers with microalbuminuria (MAU) in north India (Lucknow) and south India (Coimbatore). The subjects comprised 145 control subjects, 233 kitchen workers from north India and 186 kitchen workers from south India. Information related to the personal and occupational history and health of the subjects at both locations were collected using a custom-made questionnaire. Worker lung function was measured using a spirometer. Blood pressure was monitored using a sphygmomanometer. Urinary MAU was measured using a urine analyzer. Indoor air monitoring in kitchens for particulate matter (PM), total volatile organic compounds (TVOC), carbon dioxide (CO2) and carbon monoxide (CO) was conducted using indoor air quality monitors. The size and shape of PM in indoor air was assessed using a scanning electron microscope (SEM). Fourier transform infrared (FTIR) spectroscopy was used to detect organic or inorganic compounds in the air samples. Particulate matter concentrations (PM2.5 and PM1) were significantly higher in both north and south Indian kitchens than in non-kitchen areas. The concentrations of TVOC, CO and CO2 were higher in the kitchens of north and south India than in the control locations (non-kitchen areas). Coarse, fine and ultrafine particles and several elements were also detected in kitchens in both locations by SEM and elemental analysis. The FTIR spectra of kitchen indoor air at both locations show the presence of organic chemicals. Significant declines in systolic blood pressure and lung function were observed in the kitchen workers with MAU at both locations compared to those of the control subjects. A higher prevalence of obstruction cases with MAU was observed among the workers in the southern region than in the controls (p < 0.01). Kitchen workers in south India have lower lung capacities and a greater risk of obstructive and restrictive abnormalities than their north Indian counterparts. The study showed that occupational exposure to multiple kitchen indoor air pollutants (ultrafine particles, PM2.5, PM1, TVOC, CO, CO2) and FTIR-derived compounds can be associated with a decline in lung function (restrictive and obstructive patterns) in kitchen workers with microalbuminuria. Further studies in different geographical locations in India among kitchen workers on a wider scale are required to validate the present findings.

1 March 2019 in Annals of Global Health
Verified
Journal Article
Open access
RKRitul Kamal
Ritul Kamal
SMSheela Misra
Sheela Misra
Interpretation of lung function test parameters is usually based on comparisons of data with reference (predicted) values based on healthy subjects. Predicted values are obtained from studies of "normal" or "healthy" subjects with similar anthropometric and ethnic characteristics. Regression models are generally used to obtain the reference values from measurements observed in a representative sample of healthy subjects. The study aims to carry out a statistical evaluation of the Indian prediction models of lung function parameters and critically evaluate the reference values for the same in an Indian context. The screening and inclusion of the articles for the study was done using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Evaluation of the prediction models has been done with respect to modeling approach, regression diagnostics and methodology protocol. The suitability of the models has also been evaluated using a checklist comprising of 8 criteria developed using the American Thoracic Society (ATS) guidelines. Using the PRISMA guidelines 32 articles with a total sample size of 25,289 subjects were included in the final synthesis. Multiple linear regression models were used in 27 articles, with one additionally using weighted least squares technique and 4 using step-wise regression method. Regression diagnostics as per the ATS guidelines were performed and reported by 22 articles. The prediction models were traditionally developed using ordinary least squares method (OLS) without examining the homoskedasticity of residuals. The quality assessment using the checklist developed revealed that only 5 articles satisfied more than 7 out of 8 criteria, and a further 8 articles satisfied less than 3 criteria of suitability of prediction models. Indian prediction models for lung function models are traditionally based on linear regression models, however with more advancement in computational power for sophisticated statistical techniques, more robust prediction models are required in the Indian context.