Ji Hyeon Kim

Prof. Dr. Ji Hyeon Kim


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Bioresource Technology
Verified
Journal Article
Closed access
PNPhan Khanh Thinh Nguyen
Phan Khanh Thinh Nguyen
GDGautam Das
Gautam Das
JKJi Hyeon Kim
Ji Hyeon Kim
HYHyon Hee Yoon
Hyon Hee Yoon

1 September 2021 in Bioresource Technology
Verified
Journal Article
Closed access
TGTamirat Redae Gebreslassie
Tamirat Redae Gebreslassie
PNPhan Khanh Thinh Nguyen
Phan Khanh Thinh Nguyen
HYHyon Hee Yoon
Hyon Hee Yoon
JKJi Hyeon Kim
Ji Hyeon Kim

19 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TLTHI HOA LE
THI HOA LE
Hyun Jong LeeHyun Jong Lee
Hyun Jong Lee
JKJi Hyeon Kim
Ji Hyeon Kim
SPSang Joon Park
Sang Joon Park
Carbon dots (CDs) demonstrate very poor fluorescence quantum yield (QY). In this study, with the help of a hydrothermal method, we combined CDs with nitrogen and phosphorus elements belonging to the VA group (in the periodic table) to form heteroatom co-doped CDs, i.e., nitrogen and phosphorus co-doped carbon dots (NPCDs). These displayed a significant improvement in the QY (up to 84%), which was as much as four times than that of CDs synthesized by the same method. The as-prepared NPCDs could be used as an “off-on” fluorescence detector for the rapid and effective sensing of ferric ions (Fe3+) and catecholamine neurotransmitters (CNs) such as dopamine (DA), adrenaline (AD), and noradrenaline (NAD). The fluorescence of NPCDs was “turned off” and the emission wavelength was slightly red-shifted upon increasing the Fe3+ concentration. However, when CNs were incorporated, the fluorescence of NPCDs was recovered in a short response time; this indicated that CN concentration could be monitored, relying on enhancing the fluorescence signal of NPCDs. As a result, NPCDs are considered as a potential fluorescent bi-sensor for Fe3+ and CN detection. Particularly, in this research, we selected DA as the representative neurotransmitter of the CN group along with Fe3+ to study the sensing system based on NPCDs. The results exhibited good linear ranges with a limit of detection (LOD) of 0.2 and 0.1 µM for Fe3+ and DA, respectively.

11 April 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
TLTHI HOA LE
THI HOA LE
JKJi Hyeon Kim
Ji Hyeon Kim
SPSang Joon Park
Sang Joon Park
In this study, a fluorescence sensor based on nitrogen and phosphorus co-doped carbon dot/silver nanoparticle (NPCD/AgNP) nanocomposites was developed for metformin hydrochloride (MFH) detection. We first utilized the reducing nature of the NPCDs to prepare AgNPs from Ag+ and subsequently prepare NPCD/AgNP nanocomposites. The nanocomposite material was characterized by various methods, including electron microscopic methods (SEM and TEM), spectroscopic methods (UV-Vis, PL, FTIR, and XPS spectroscopy), light scattering (ELS), and XRD. Further, we utilized the enhanced fluorescence of the NPCDs as well as the overlap between the fluorescence emission spectrum of the NPCDs and the absorption spectrum of the AgNPs to use the NPCD/AgNP nanocomposites as an effective inner filter effect (IFE) pair for sensing MFH. The IFE between NPCDs and AgNPs in the nanocomposite material resulted in a significant quenching of the fluorescence intensity of the nanocomposites compared to that of the pure NPCDs. However, the fluorescence was recovered when MFH was introduced into the nanocomposite solution. The fluorescence intensity of the nanocomposites increased linearly as the MFH concentration increased from 2 to 100 µg/L. This detection method showed good sensitivity compared to other methods. It also showed high selectivity and high sensing potential for MFH in human serum and yielded acceptable results.

Verified
Journal Article
Open access
PDF file
TLTHI HOA LE
THI HOA LE
JKJi Hyeon Kim
Ji Hyeon Kim
SPSang Joon Park
Sang Joon Park
Glutathione (GSH) is a thiol that plays a significant role in nutrient metabolism, antioxidant defense and the regulation of cellular events. GSH deficiency is related to variety of diseases, so it is useful to develop novel approaches for GSH evaluation and detection. In this study we used nitrogen and phosphorus co-doped carbon dot-gold nanoparticle (NPCD–AuNP) composites to fabricate a simple and selective fluorescence sensor for GSH detection. We employed the reductant potential of the nitrogen and phosphorus co-doped carbon dots (NPCDs) themselves to form AuNPs, and subsequently NPCD–AuNP composites from Au3+. The composites were characterized by using a range of spectroscopic and electron microscopic techniques, including electrophoretic light scattering and X-ray diffraction. The overlap of the fluorescence emission spectrum of NPCDs and the absorption spectrum of AuNPs resulted in an effective inner filter effect (IFE) in the composite material, leading to a quenching of the fluorescence intensity. In the presence of GSH, the fluorescence intensity of the composite was recovered, which increased proportionally to increasing the GSH concentration. In addition, our GSH sensing method showed good selectivity and sensing potential in human serum with a limit of detection of 0.1 µM and acceptable results.

1 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
TLTHI HOA LE
THI HOA LE
Hyun Jong LeeHyun Jong Lee
Hyun Jong Lee
JKJi Hyeon Kim
Ji Hyeon Kim
SPSang Joon Park
Sang Joon Park
In our research, a reliable fluorescence sensor for the detection of sulfamethoxazole (SMZ) was developed. This method relies on graphene quantum dots (GQDs) entrapped in a silica molecularly imprinted polymer (GQDs@SMIP), which was synthesized by the polymerization using GQDs, SMZ, tetraethoxysilane (TEOS) and 3-aminopropyltriethoxysilane (APTES) as fluorescence material, template, cross-linker, and functional monomers, respectively. The GQDs@SMIP was characterized by fluorometry, Fourier-transform infrared spectroscopy, transmission and scanning electron microscopies, X-ray photoelectron spectroscopy, and powder X-ray diffraction. The GQDs@SMIP exhibited a good capacity to absorb SMZ from solution, which resulted in the quenching of the GQD fluorescence intensity. The intensity of GQDs@SMIP decreased linearly with the SMZ concentration in the range of 1 to 100 µM with a correlation coefficient of 0.99537. In addition, the fluorescence responses of GQDs@SMIP to interfering substances were investigated. The results indicated that there was no effect of interfering substances on SMZ detection. Thus, the highly selective GQDs@SMIP fluorescence sensor is an effective and promising device for SMZ detection and analysis.