Mark Keith Hewitt

Dr. Mark Keith Hewitt

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2024 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
SSSameer Sharif
Sameer Sharif
JKJasmine Kang
Jasmine Kang
Behnam SadeghiradBehnam Sadeghirad
Behnam Sadeghirad
FRFayyaz Rizvi
Fayyaz Rizvi
BFBen Forestell
Ben Forestell
BRBram Rochwerg
Bram Rochwerg

Verified
Journal Article
Open access
PDF file
PKPeter Kavsak
Peter Kavsak
SMShawn E. Mondoux
Shawn E. Mondoux
JMJanet Martin
Janet Martin
MHMark Keith Hewitt
Mark Keith Hewitt
LCLorna Clark
Lorna Clark
AWAndrew Worster
Andrew Worster
Differences in patient classification of myocardial injury between high-sensitivity cardiac troponin (hs-cTn) assays have largely been attributed to assay design and analytical sensitivity aspects. Our objective was to compare Ortho Clinical Diagnostics’ (OCD) hs-cTnI assay to OCD’s contemporary/conventional assay (cTnI ES) and another hs-cTnI assay (Abbott hs-cTnI) in samples obtained from different emergency departments (EDs). Two different sample types were evaluated (lithium heparin and ethylenediaminetetraacetic acid (EDTA) plasma) in a non-selected ED population (study 1, n = 469 samples) and in patients for which ED physicians ordered cardiac troponin testing (study 2, n = 1147 samples), from five different EDs. The incidence of injury in study 1 was higher with the OCD hs-cTnI assay (30.9%; 95% CI: 26.9 to 35.2) compared to that of the Abbott hs-cTnI (17.3%; 95% CI: 14.1 to 21.0) and the OCD cTnI ES (15.4%; 95% CI: 12.4 to 18.9) assays, with repeat testing identifying 4.8% (95% CI: 3.0 to 7.5) of the OCD hs-cTnI results with poor reproducibility. In study 2, 4.6% (95% CI: 3.5 to 6.0) of the results were not reported for the OCD hs-cTnI assay (i.e., poor reproducibility) with 12.7% (95%CI: 8.7 to 17.8) of the OCD hs-cTnI results positive for injury being negative for injury with the Abbott hs-cTnI assay. In summary, the OCD hs-cTnI assay yields higher rates of biochemical injury with a higher rate of poor reproducible results in different ED populations.

Verified
Journal Article
Open access
PDF file
PKPeter Kavsak
Peter Kavsak
MHMark Keith Hewitt
Mark Keith Hewitt
SMShawn E. Mondoux
Shawn E. Mondoux
JCJoshua O. Cerasuolo
Joshua O. Cerasuolo
JMJinhui Ma
Jinhui Ma
AWAndrew Worster
Andrew Worster
Serial high-sensitivity cardiac troponin (hsTn) testing in the emergency department (ED) and the intensive cardiac care unit may assist physicians in ruling out or ruling in acute myocardial infarction (MI). There are three major algorithms proposed for high-sensitivity cardiac troponin I (hsTnI) using serial measurements while incorporating absolute concentration changes for MI or death following ED presentation. We sought to determine the diagnostic estimates of these three algorithms and if one was superior in two different Canadian ED patient cohorts with serial hsTnI measurements. An undifferentiated ED population (Cohort-1) and an ED population with symptoms suggestive of acute coronary syndrome (ACS; Cohort-2) were clinically managed with non-hsTn testing with the hsTnI testing performed in real-time with physicians blinded to these results (i.e., hsTnI not reported). The three algorithms evaluated were the European Society of Cardiology (ESC), the High-STEACS pathway, and the COMPASS-MI algorithm. The diagnostic estimates were derived for each algorithm for the 30-day MI/death outcome for the rule-out and rule-in arm in each cohort and compared to proposed diagnostic benchmarks (i.e., sensitivity ≥ 99.0% and specificity ≥ 90.0%) with 95% confidence intervals (CI). In Cohort-1 (n = 2966 patients, 15.3% had outcome) and Cohort-2 (n = 935 patients, 15.6% had outcome), the algorithm that obtained the highest sensitivity (97.8%; 95% CI: 96.0–98.9 and 98.6%; 95% CI: 95.1–99.8, respectively) in both cohorts was COMPASS-MI. Only Cohort-2 with both the ESC and COMPASS-MI algorithms exceeded the specificity benchmark (97.0%; 95% CI: 95.5–98.0 and 96.7%; 95% CI: 95.2–97.8, respectively). Patient selection for serial hsTnI testing will affect specificity estimates, with no algorithm achieving a sensitivity ≥ 99% for 30-day MI or death.

11 May 2023 in Journal of Critical Care
Verified
Journal Article
Closed access
MLMelissa Lannon
Melissa Lannon
TDTaylor Duda
Taylor Duda
AGAlisha Greer
Alisha Greer
MHMark Keith Hewitt
Mark Keith Hewitt
ASArjun Sharma
Arjun Sharma
SSSunjay Sharma
Sunjay Sharma

Verified
Journal Article
Open access
PDF file
PKPeter Kavsak
Peter Kavsak
SMShawn E. Mondoux
Shawn E. Mondoux
MHMark Keith Hewitt
Mark Keith Hewitt
CACraig Ainsworth
Craig Ainsworth
SHStephen Hill
Stephen Hill
AWAndrew Worster
Andrew Worster
Guidelines published in 2021 have supported natriuretic peptide (NP) testing for the prognostication in patients with acute coronary syndrome (ACS) and for the diagnosis of chronic and acute heart failure (HF). Our objective was to determine if the addition of N-terminal pro B-type NP (NT-proBNP) and glucose to high-sensitivity cardiac troponin (hs-cTn) could better identify emergency department (ED) patients with potential ACS at low- and high-risk for a serious cardiovascular outcome over the next 72 h. The presentation sample in two different ED cohorts which enrolled patients with symptoms suggestive of ACS within six hours of pain onset (Cohort-1, n = 126 and Cohort-2, n = 143) that had Abbott hs-cTnI, Roche hs-cTnT, NT-proBNP and glucose were evaluated for NT-proBNP alone and combined with hs-cTn and glucose for the primary outcome (composite which included death, myocardial infarction, HF, serious arrhythmia and refractory angina) via receiver-operating characteristic (ROC) curve analyses with area under the curve (AUC) and diagnostic estimates derived. The AUC for NT-proBNP for the primary outcome was 0.68 (95% confidence interval (CI): 0.59–0.76) and 0.75 (95%CI: 0.67–0.82) in Cohort-1 and 2, respectively, with the 125 ng/L cutoff yielding a higher sensitivity (≥75%) as compared to the 300 ng/L cutoff (≥58%). Using the 125 ng/L cutoff for NT-proBNP with the published glucose and hs-cTn cutoffs for risk-stratification produced a new score (GuIDER score for Glucose, Injury and Dysfunction in the Emergency-setting for cardiovascular-Risk) and yielded higher AUCs as compared to NT-proBNP (p < 0.05). GuIDER scores of 0 and 5 using either hs-cTnI/T yielded sensitivity estimates of 100% and specificity estimates > 92% for the primary outcome. A secondary analysis assessing MI alone in the overall population (combined Cohorts 1 and 2) also achieved 100% sensitivity for MI with a GuIDER cutoff ≥ 2, ruling-out 48% (Roche) and 38% (Abbott) of the population at presentation for MI. Additional studies are needed for the GuIDER score in both the acute and ambulatory setting to further refine the utility, however, the preliminary findings reported here may present a pathway forward for inclusion of NP testing for ruling-out serious cardiac events and MI in the emergency setting.

5 March 2026 in Emergency Care and Medicine
Verified
Journal Article
Open access
PDF file
MHMark Keith Hewitt
Mark Keith Hewitt
KBKurtis Butt
Kurtis Butt
AGAlisha Greer
Alisha Greer
AFAlison Fox-Robichaud
Alison Fox-Robichaud
Background: Lemierre’s syndrome (LS), previously termed the “forgotten disease” after the introduction of modern antibiotics, is a rare and potentially fatal infection of the neck resulting in septic thrombophlebitis of the internal jugular and other neck veins. In recent years, there has been an increased resurgence of this disease, or at least in its detection, and it remains an important diagnosis with life-threatening potential to consider when presenting with multifocal cavitary pneumonia. Fusobacterium necrophorum, an obligate anaerobic Gram-negative bacterium, is the most isolated culprit organism involved in this condition; however, it is often fastidious and difficult to culture. The use of 16s rRNA gene sequencing can aid in this diagnosis when uncertainty exists. Methods: This case report describes an otherwise healthy 17-year-old male with a history of regular vaping presenting with upper respiratory infectious symptoms who was ultimately diagnosed with multifocal necrotizing pneumonia. In this case, there was initial diagnostic uncertainty as traditional microbiologic culture mechanisms failed to identify a causative organism for tailored antimicrobial treatment. This was despite direct empyema fluid analysis and pulmonary-bronchial biopsy. Novel gene sequencing was performed using 16s rRNA typing, a promising new way to identify a catalog of host organisms, detecting F. necrophorum. This diagnosis prompted further diagnostic imaging of the neck, confirming a small internal jugular clot and diagnosis of LS. Results: This case highlights the need for suspicion of LS in patients presenting with multifocal pneumonia. Furthermore, it re-iterates the idea of culture-negative infections, whereby fastidious organisms or tissue samples do not readily provide a diagnosis. Lastly, it further introduces hypotheses regarding the use of vaping as a possible associated factor for significant infection and lung injury. Conclusions: The use of 16s rRNA sequencing for the detection of fastidious, opportunistic organisms is another tool for physicians to ensure additional diagnostic clarity and appropriate treatment.