1 April 2022 in Scientific Reports
An optical-based label-free biosensors including two indirectly coupled double-slot-waveguide-based microring resonator was designed and optimized for sensing purpose. Then, the optimized system was applied for the detection of hemoglobin concentration in anemia disease. The results were simulated based on the variational finite-difference time domain (varFDTD) method using the Lumerical software (Mode solutions) and the optimum geometrical parameters were determined to realize an optimum light transmission via the sensor. Nine different concentrations of hemoglobin in men and women were applied into the sensor and the status of anemia was identified based on the patients’ gender and different status of anemia disease, including the normal, mild, moderate, severe and life-threatening status. A sensitivity as high as 1024 nm/RIU with the minimum deflection limit of 4.88 × 10–6 RIU were measured for this biosensor, which introduces a high precision and micro-scale lab-on-a-chip micro device for health monitoring of the anemia.
15 August 2019 in Journal of Theoretical and Applied Physics
In this paper, we introduced double-critical coupling condition (DCCC) for lossy mode couplers of the add–drop resonator to achieve the desirable and tunable signals required for optical communication and photonics sensors applications. The performance of add–drop resonator under double-critical condition is simulated and analyzed. Some equations were derived for optical parameters including full width at half maximum (FWHM), the out-of-band rejection ratio (OBRR), quality factor and the crosstalk of the add–drop resonator, and the output signals were examined as a function of DCCC. Based on double-critical condition, the OBRR values larger than 40 dB, the crosstalk larger than 50 dB, highest quality factor of 9000 and the FWHM as small as 0.17 nm were realized in silicon add–drop resonator, which are quite compatible with the reported experimental data. Double-critical condition shows that the lossless coupling is not enough condition to acquire high-quality filtered signal with a large crosstalk and in presence of coupling losses, the DCCC can determine the optimum relation between the strength of coupling coefficients and the coupling losses.
5 January 2021 in Silicon
30 October 2020 in The European Physical Journal Plus
15 October 2019 in Applied Optics
A stereo resonating system, including two cascaded Panda resonators with two small rings is proposed as a microscale active stereo system. The optical transfer functions of the Panda stereo system for two input ports and one output port are derived using the coupled mode theory. The feasibility of the Panda stereo system to realize three-dimensional content is investigated by applying different coupling coefficients and materials to each Panda resonator. The effect of the coupling strength of the ${3} \times {3}$ coupler on the output light is also studied. It is interesting that a portion of input light into the Panda stereo system can undergo a wavelength shift and an intensity shift by adjusting the coupling coefficients of the ${3} \times {3}$ coupler together with fine-tuning the refractive index of one of the Panda resonators. Results show that a change of the ${3} \times {3}$ coupler brings about a shift from 0.1 to 37 dB in light transmission and applying a change of $\delta n = 0.01$ in the refractive index of one of the Panda resonators generated a phase shift larger than $\pi /{4}$, which is required for image depth reconstruction. The advantages of the proposed Panda stereo system compared to the conventional stereo technology are low cost and a microsize, with a simple structure and the ability to work in a different wavelength spectrum range.
27 August 2020 in Microwave and Optical Technology Letters