Sahil Bhagat

Mr. Sahil Bhagat


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
Katarina VranešićKatarina Vranešić
Katarina Vranešić
SBSahil Bhagat
Sahil Bhagat
Andrea MariscottiAndrea Mariscotti
Andrea Mariscotti
RVRobert Vail
Robert Vail
Stray currents can cause very rapid degradation and material loss at the points where the current leaves the metal and enters the electrolyte. Nowadays, many resources are invested in the protection of jeopardized structures, such as buried pipelines, from stray current corrosion. This paper describes the measures that need to be considered in the design and construction of track structures to ensure high rail-to-ground resistance and consequently reduce stray currents. The main conclusions from existing guidelines and standards for reducing and controlling stray currents that are applied by various track operators are presented in the paper. Rail-to-ground resistance in different types of tracks structures and rail fastening systems is analyzed, and the optimal type of the track and type of the fastening system is defined. The grounding schemes used on the tracks and their influence on stray current values are described, as well as the influence of traction power stations (TPS) and rail cross bonding on stray current. Since it is not necessary to apply all the measures described to the same track structure, the paper gives recommendations on which measures to apply when building tracks with continuously fastened rails and which to apply when building tracks with discretely supported and fastened rails.

25 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SBSahil Bhagat
Sahil Bhagat
JBJacopo Bongiorno
Jacopo Bongiorno
Andrea MariscottiAndrea Mariscotti
Andrea Mariscotti
Stray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct design choices. The assessment of track insulation is the starting point for both stray current monitoring systems and at commissioning or upon major changes. Standardized methods (ref. EN 50122-2 or IEC 62128-2) have been almost unchanged in the last 20 years but suffer from accuracy issues and variability due to parameters and conditions not under the operator’s control. The uncertainty of test methods is increasingly important now that contractual specifications require a high level of insulation for new systems. A critical discussion and analysis of the sources of variability and practical constraints is proposed, followed by an evaluation of uncertainty, with the objective not only to assess the accuracy of the provided results, but also to foster research on innovative, more flexible and accurate methods.

22 July 2024 in Electronics
Verified
Journal Article
Open access
PDF file
SBSahil Bhagat
Sahil Bhagat
Andrea MariscottiAndrea Mariscotti
Andrea Mariscotti
The demonstration of compliance of rolling stock against disturbance limits for railway signaling, and in particular track circuits, is subject to a large deal of variability, caused by the diverse values of the electrical parameters of the railway line and resulting transfer functions, as well as the operating conditions of the rolling stock during tests. Instrumental uncertainty is evaluated with a type B approach and shown to be much less than the experimental variability. Repeated test runs in acceleration, coasting, cruising, and braking conditions are considered, deriving both max-hold (spread) and sample (or experimental) standard deviation curves compared to the respective mean values (type A approach to the evaluation of uncertainty, as defined in of the Guide to the Uncertainty in Measurement. The major source of variability affecting a significant portion of the spectrum is caused by the superposed oscillations of the onboard LC filter, for which different choices of the transformation window duration are discussed. The test runs and the acquired data covered, overall, 1 day of tests along about 300 km of the Italian 3 kV DC railway network.

9 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
SBSahil Bhagat
Sahil Bhagat
JBJacopo Bongiorno
Jacopo Bongiorno
Andrea MariscottiAndrea Mariscotti
Andrea Mariscotti
Energy efficiency is more and more important for modern electrified transportation systems, requiring an understanding of the various indexes of performance (regenerability, receptivity, and energy losses, thus including braking recovered energy and energy loss in catenary) and of the influence of the main system parameters (headway, line voltage, substation separation, etc.). By means of electromechanical simulation, the most relevant parameters and system conditions are identified as influencing the efficiency performance and optimization capability. Besides the assessment of such efficiency performance indexes, identifying their typical ranges of variation, one further outcome is the identification of characteristic system parameter combinations that lead to extreme variations in the system energy efficiency itself. Such peculiar variations are caused by occasionally synchronized patterns of trains along the line and result in a significant local increase or decrease in efficiency. Efficiency drop scenarios in particular should be taken into consideration for worst-case analysis and to devise effective mitigations. To this aim, the effect of differently distributed passenger stations is considered.

2 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Katarina VranešićKatarina Vranešić
Katarina Vranešić
SBSahil Bhagat
Sahil Bhagat
Andrea MariscottiAndrea Mariscotti
Andrea Mariscotti
RVRobert Vail
Robert Vail
Stray currents can cause very rapid degradation and material loss at the points where the current leaves the metal and enters the electrolyte. Nowadays, many resources are invested in the protection of jeopardized structures, such as buried pipelines, from stray current corrosion. This paper describes the measures that need to be considered in the design and construction of track structures to ensure high rail-to-ground resistance and consequently reduce stray currents. The main conclusions from existing guidelines and standards for reducing and controlling stray currents that are applied by various track operators are presented in the paper. Rail-to-ground resistance in different types of tracks structures and rail fastening systems is analysed and optimal type of the track and type of the fastening system is defined. The grounding schemes used on the tracks and their influence on stray current values are described, as well as the influence of traction power substation and rail cross bonding on stray current. Since it is not necessary to apply all the measures described to the same track structure, the paper gives recommendations on which measures to apply when building tracks with continuously fastened rails and which to apply when building tracks with discretely supported and fastened rails.

18 February 2026 in Electronics
Verified
Journal Article
Open access
PDF file
SBSahil Bhagat
Sahil Bhagat
Andrea MariscottiAndrea Mariscotti
Andrea Mariscotti
Mattia SimonazziMattia Simonazzi
Mattia Simonazzi
Leonardo SandroliniLeonardo Sandrolini
Leonardo Sandrolini
This paper presents a constraint-aware and systematic methodology for the design of LCL filters in grid-connected electric vehicle (EV) fast chargers. The proposed step-by-step process provides analytical sizing equations for the passive components L1, L2, and C while explicitly accounting for key design trade-offs such as voltage drop, reactive power draw, resonance frequency, and harmonic attenuation. Unlike conventional practice, which often relies on oversized inductors, the proposed approach selects inductance values near the permissible lower bound, resulting in a more compact and cost-effective filter solution. A 100 kVA bidirectional converter model was used to validate the design through time-domain simulations. Results show that the proposed filter maintains a grid current total harmonic distortion of less than 2% and limits individual high-order harmonics to below 0.3%, fully complying with IEEE Std. 519 taken as reference among other power quality standards. By selecting the minimum inductance that satisfies these limits, the required inductor mass is reduced by approximately 67% compared with a conservative design, translating into substantial savings in size and cost. The methodology is scalable to other power ratings by updating the base parameters, providing a practical design tool for EV charger manufacturers and utilities to achieve higher efficiency, lower cost, and reliable grid-code compliance.